Plan Review Details - Permit 05090538
Plan Review Stops For Permit 05090538 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-10-12 |
Time |
13:32 |
Rev Time |
2.00 |
Received By |
mjacobs |
Date |
2005-10-12 |
Time |
11:35 |
Sent To |
|
|
Notes |
2005-10-12 00:00:00 | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE CITY OF WPB DOES NOT USE THE | | SOUTH FLORIDA BUILDING CODE BOOK. THE | | CODE BOOK WE USE IS THE FLORIDA BUILDING | | CODE 2001. HOWEVER, AS OF OCTOBER 1ST WE | | WILL BE USING THE 2004 FLORIDA BUILDING | | CODE BOOK. | | | | 3) IF THIS STRUCTURE IS DESIGN UNDER THE | | 2001 CODE, IT WILL HAVE TO BE DESIGNED | | TO WITH-STAND 140MPH WITH THE CANVAS | | AWNING IN PLACE.SEE FBC 2001 SEC. | | 1606.1.6 AND 1606.1.7 FOR BASIC WIND | | SPEEDS. | | | | 4) IF THIS STRUCTURE IS DESIGNED FOR THE | | CANVAS TO BE REMOVED AT 75MPH WIND | | SPEED. IT WILL HAVE TO BE DESIGN USING | | THE 2004 CODE.SEC 3105. ALSO A NOTORIZE | | LETTER FROM THE OWNER STATING THAT THE | | CANVAS WILL BE REMOVED AT WIND SPEEDS OF | | 75MPH SHALL BE SUBMITTED FOR REVIEW. | | | | 5) WHAT IS THE HEIGHT OF THE STRUCTURE? | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-21 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-21 |
Time |
08:28 |
Sent To |
B |
|
Notes |
2005-09-21 00:00:00 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-13 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-13 |
Time |
13:31 |
Sent To |
Z |
|
Notes |
2005-09-13 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-20 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-20 |
Time |
16:55 |
Sent To |
I |
|
Notes |
2005-09-20 00:00:00 | CARPORT SITS BEYOND THE 25FT FRONT | | SETBACK AND IS ATTACHED TO MAIN | | STRUCTURE. |
|
|
|