Plan Review Details - Permit 05090376
Plan Review Stops For Permit 05090376 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-09-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-09-15 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-09-15 |
Time |
07:40 |
Sent To |
|
|
Notes |
2005-09-15 00:00:00 | BUILDING PLAN REVIEW | | PERMIT:05090376 | | ADD:3701 S. FLAGLER #B204 | | CONT:NICK RAICH BLDG. CORP. | | TEL: (561)659-9347 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: BUILDING PROVISO | | | | 803.4 FOAM PLASTICS. FOAM PLASTICS SHALL | | NOT BE USED AS INTERIOR FINISH. | | | | EXCEPTION: FOAM PLASTIC TRIM, DEFINED | | AS PICTURE MOLDS, CHAIR RAILS, | | BASEBOARDS, HANDRAILS, CEILING BEAMS, | | DOOR TRIM AND WINDOW TRIM SHALL BE | | PERMITTED TO BE USED PROVIDED: | | | | 1. THE MINIMUM DENSITY IS 20 LB/CU FT | | (320 KG/M^3). | | | | 2. THE MAXIMUM THICKNESS OF THE TRIM | | IS 1/2 INCH (12.7 MM) AND THE | | MAXIMUM WIDTH IS 4 INCHES (102 MM). | | | | 3. THE TRIM CONSTITUTES NO MORE THAN | | 10 PERCENT OF THE AREA OF ANY WALL | | OR CEILING. | | | | 4. THE FLAMESPREAD RATING DOES NOT | | EXCEED 75 WHEN TESTED PER ASTM E 84. | | THE SMOKE DEVELOPED RATING IS NOT | | LIMITED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-29 |
Time |
08:07 |
Rev Time |
|
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | NO ELECTRICAL WORK DISCRIBED ON PLANS OR | | APPLICATION |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-09-16 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-09-16 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-09-29 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-09-13 |
Time |
09:13 |
Sent To |
|
|
Notes |
2005-09-13 00:00:00 | TO "BOB"#11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-09-19 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-09-19 |
Time |
09:49 |
Sent To |
|
|
Notes |
2005-09-19 00:00:00 | 9/19/05 NO MECHANICAL REQUIRED.HM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-29 |
Time |
08:06 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-29 |
Time |
08:06 |
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | FIXTURE CHANGE OUT ONLY. |
|
|
|