Plan Review Stops For Permit 05090251 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-16 |
Time |
07:06 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2005-12-15 |
Time |
14:53 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-30 |
Time |
10:21 |
Rev Time |
1.66 |
Received By |
alange |
Date |
2005-09-30 |
Time |
09:19 |
Sent To |
|
|
Notes |
2005-09-30 00:00:00 | DENIED | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.ON TAMCO ROOF PRODUCT APPROVAL | | SELECT THE ASSEMBLY THE WILL BE | | INSTALLED. | | | | 3.SUBMIT PRODUCT APPROVALS FOR STRAPS | | AND TIE-DOWNS. | | ALL PRODUCT APPROVALS SUBMITTED SHALL | | HAVE THE FOLLOWING STATE PRODUCT | | APPROVALS ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-30 |
Time |
10:50 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-05-30 |
Time |
10:06 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-09-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-09-23 |
Time |
16:54 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-09-22 |
Time |
07:10 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-26 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-26 |
Time |
16:20 |
Sent To |
E |
|
Notes |
2006-05-26 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-15 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-15 |
Time |
11:17 |
Sent To |
M |
|
Notes |
2006-05-15 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-12-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-02 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-02 |
Time |
09:17 |
Sent To |
P |
|
Notes |
2005-12-02 00:00:00 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-16 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-16 |
Time |
16:05 |
Sent To |
E |
|
Notes |
2005-09-16 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-12 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-12 |
Time |
08:42 |
Sent To |
Z |
|
Notes |
2005-09-12 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-30 |
Time |
14:27 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-05-30 |
Time |
14:27 |
Sent To |
|
|
Notes |
2006-05-30 00:00:00 | REVISION TO MECH. PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-05-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-16 |
Time |
11:43 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-05-16 |
Time |
11:43 |
Sent To |
|
|
Notes |
2006-05-16 00:00:00 | *** DENIED *** | | 1) ORIGINAL MECHANICAL PLANS WERE DONE | | BY AN ARCHITECT (ROBOR JANSSEN) AND ONLY | | HE CAN MAKE REVISONS, OR YOU MAY GET A | | LETTER OF RELEASE FROM HIM. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-27 |
Time |
08:41 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2005-09-27 |
Time |
08:41 |
Sent To |
P |
|
Notes |
2005-09-27 00:00:00 | * NEED NOTICE OF COMMENCEMENT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-14 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2005-12-16 |
Time |
07:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-09-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-28 |
Time |
16:09 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-09-28 |
Time |
16:09 |
Sent To |
B |
|
Notes |
2005-09-28 00:00:00 | DENIED; | | 1.WATER HEATER DETAIL ON PAGE P-1 DOES | | NOT COMPLY, PLEASE DELETE OR CHANGE. NOT | | 24 80 GAL HEATER TO BE INSTALLED. PLAN | | SHOWS HEATER IN MECHANICAL ROOM. | | 2.THERMAL EXPANSION CONTROL REQUIRED SEE | | SEC. 607.3. | | 3.RISER DIAGRAM NOT TO CODE. BAR SINK | | AND FLOOR DRAIN MUST DISCHARGE DOWN | | STREAM OF BATHROOM GROUP, SEE SEC. | | 909.1. NOTE TRAP TO BE DEEP SEAL TYPE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-16 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-16 |
Time |
14:40 |
Sent To |
I |
|
Notes |