Plan Review Details - Permit 05090229
Plan Review Stops For Permit 05090229
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-02-24 Cont ID  
Sent By jgomez Date 2006-02-24 Time 19:00 Rev Time 0.40
Received By jgomez Date 2006-02-24 Time 18:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-11-17 Cont ID  
Sent By jgomez Date 2005-11-17 Time 11:14 Rev Time 0.50
Received By jgomez Date 2005-11-17 Time 11:14 Sent To PC
Notes
2005-11-17 00:00:00BUILDING REVIEW SECOND CHECKLIST:
 1- ENGINEER DIDN'T ADDRESSED COMMENTS
 REQUESTED ON PRIOR CHECKLIST DATED
 10-6-05. SEE COMPLETE ITEM #2 ON
 ATTACHED COPY OF THE CHECKLIST AND
 ADDRESS ALL THE ITEMS.
  
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-06 Cont ID  
Sent By jgomez Date 2005-10-06 Time 16:41 Rev Time 0.33
Received By jgomez Date 2005-10-06 Time 16:41 Sent To PC
Notes
2005-10-06 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- ROLLAFLEX SHADE:
 A) EVEN THOUGH THIS PRODUCT IS NOT USED
 FOR HURRICANE MISSILE IMPACT PROTECTION,
 STILL IT NEEDS TO MEET THE DESIGN
 CRITERIA OF SEC. 1606 FBC 2001. PRODUCT
 WAS DESIGNED FOR 90MPH. NEED TO COMPLY
 WITH THE 140MPH 3 SECOND GUST WIND LOAD
 DESIGN.
  
 B) WIND LOAD TABLE 3.44 IS NOT PREPARED
 BY THE SAME ENGINEER WHO DESIGNED THE
 ROLLAFLEX SHADE. NEED TO BE SIGNED AND
 SEALED BY THE CONSULTING ENGINEER SHOWN
 ON THE TITLE BLOCK AT BOTTOM OF PAGE AS
 REQ'D BY CHAPTER 471 OF FL. STATUTES.
  
 C) WIND LOAD TABLE 3.44: CLARIFY WHY
 USING TRIBUTARY AREA OF 100S.F.SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 D) PROVIDE DETAILS AND SPECIFICATIONS
 FOR ANCHORING OF UPPER BOX SUPPORTING
 THE ROLLAFLEX SHADE WHEN IT'S IN OPEN
 POSITION. MUST RESIST 140MPH 3 SECOND
 GUST WIND LOAD. SEC. 1606 FBC 2001.
  
 E) ENGINEER TO PROVIDE ALL HIS
 INFORMATION ON SIGNED AND SEALED
 DRAWINGS AS REQUIRED BY CHAPTER 471 FL.
 STATUTES & FLORIDA ADMINISTRATIVE CODE
 61G15-23.002.
  
 F) PROVIDE SPECS/DETAILS OF HOW IS THE
 SHADE OPENED/CLOSED. IS IT DONE MANUALLY
 OR POWERED?. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001. (ELECTRIC PERMIT
 IS REQUIRED FOR POWERED OPERATION).
  
 G) PROVIDE 2 ORIGINAL SIGNED AND SEALED
 DRAWINGS. NOT COPIES. CHAPTER 471
 FLORIDA STATUTES.
  
 3- IF THE INTENTION IS TO PROTECT ALL
 DWELLING OPENINGS, THEN CLARIFY WHY THE
 LARGER OPENING IS NOT GOING TO BE
 PROTECTED. LEAVING OPENINGS WITHOUT
 PROTECTION (SPECIALLY A LARGE OPENING)
 DECEIVES THE PURPOSE OF PROTECTING THE
 DWELLING. DWELLING WILL BE PARTIALLY
 OPEN IF THE GLASS BRAKES AND THE OTHER
 SHUTTERS MAY BE BLOWN AWAY BECAUSE OF
 THE INTERNAL PRESSURES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-19 Cont ID  
Sent By adarroug Date 2006-02-19 Time 11:14 Rev Time 0.00
Received By adarroug Date 2006-02-19 Time 11:14 Sent To B
Notes
2006-02-19 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-11-16 Cont ID  
Sent By adarroug Date 2005-11-16 Time 14:34 Rev Time 0.00
Received By adarroug Date 2005-11-16 Time 14:34 Sent To B
Notes
2005-11-16 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-09 Cont ID  
Sent By adarroug Date 2005-09-09 Time 16:59 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 16:59 Sent To B
Notes
2005-09-09 00:00:00TO "MISC" BOX#1