Plan Review Stops For Permit 05090211 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-06-08 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-06-08 |
Time |
08:56 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-05-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-05-23 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-05-23 |
Time |
06:59 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-05-01 |
Time |
17:49 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-05-01 |
Time |
17:06 |
Sent To |
PC |
|
Notes |
2006-05-01 00:00:00 | 1) THE SPECIFICATIONS FOR THE SWIM SPA | | SHOWS THE SIZE AS A 20'X 40' SPA. | | HOWEVER THE DRAWING OF THE SAME SWIM SPA | | INDICATES A 7'X 22' SPA. THE DRAWING AND | | THE SPECIFICATION MUSTCORRESPOND WITH | | EACH OTHER. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL(561)805-6726 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-04-18 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-04-18 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-04-17 |
Time |
18:53 |
Sent To |
PC |
|
Notes |
2006-04-18 00:00:00 | 1)ONLY THE PERSON WHO SEAL AND SIGNED | | THE DRAWINGS ARE ALLOWED TO MAKE CHANGES | | ON THE DRAWINGS. ANY HAND WRITTEN | | CHANGES, WILL HAVE TO BE SIGNED,DATED | | AND INITIAL BY THAT PERSON OR SUBMIT NEW | | DRAWINGS WITH ALL THE CHANGES. | | | | 2) THE TWO SETS OF DRAWINGS HAVE TO BE | | THE SAME. ONE SET OF DRAWINGS HAS HAND | | WRITTEN CHANGES WHILE THE OTHER DOES | | NOT. FL 61G1-23.015 (2) THE ARCHITECT IS | | RESPONSIBLE FOR SUPERVISING AND | | REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC... | | | | 3) WPB CITY AMENDMENTS. 106.1.3 THE | | BUILDING OFFICIAL MAY SET STANDARDS | | THROUGH DEPARTMENTAL POLICY STANDARDS | | FOR PLANS AND SPRCIFICA TIONS. "NO WHITE | | OUT". | | | | 4) WILL THE SPA BE CHANGED TO A POOL? | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-04-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-04-08 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-04-07 |
Time |
17:21 |
Sent To |
PC |
|
Notes |
2006-04-08 00:00:00 | 1) THE DRAWINGS ON FILE IS FOR A SPA. | | THE SIZE FOR THE SPA IS 9'X 13.5'. NOW | | THE REVISION SUBMITTED IS FOR A POOL | | WHICH IS 20' X 40'. IS THIS CORRECT? | | BECAUSE THE DRAWINGS INDICATE A SPA AND | | THE SPECIFICATIONS REFERS TO A POOL. | | REMEMBER ALL INFORMATION SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED. HOWEVER THE DIMENTIONS GIVEN | | ON THE SPECIFICATIONS DOES NOT | | CORRESPOND WITH THE DRAWINGS PLEASE | | CLARIFY. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-02-09 |
Time |
07:57 |
Rev Time |
1.00 |
Received By |
mjacobs |
Date |
2006-02-09 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-10-04 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-10-04 |
Time |
13:35 |
Rev Time |
2.25 |
Received By |
mjacobs |
Date |
2005-10-04 |
Time |
10:40 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-01 |
Time |
11:36 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-05-01 |
Time |
11:19 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-04-06 |
Time |
10:31 |
Rev Time |
0.30 |
Received By |
jleahy |
Date |
2006-04-06 |
Time |
10:31 |
Sent To |
P |
|
Notes |
2006-04-06 00:00:00 | PUT IN RESULTS FOR P PETTYJL |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-06 |
Time |
12:15 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-02-06 |
Time |
12:06 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-09-14 |
Time |
13:49 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-09-14 |
Time |
13:27 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-01 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-05-01 |
Time |
11:56 |
Sent To |
B |
|
Notes |
2006-05-01 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT | | APPLICATION. ALL GAS INSPECTIONS TO BE | | COMPLETE BEFORE FINAL POOL INSPECTION. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-06 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-04-06 |
Time |
13:35 |
Sent To |
B |
|
Notes |
2006-04-06 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT | | APPLICATION. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-04 |
Time |
14:27 |
Rev Time |
|
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2005-10-04 00:00:00 | NO INFORMATION FOR GAS PLAN REVIEW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-06 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-06 |
Time |
15:15 |
Sent To |
B |
|
Notes |
2006-06-06 00:00:00 | TO "MJACOBS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2006-05-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-27 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-27 |
Time |
13:25 |
Sent To |
Z |
|
Notes |
2006-05-27 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-22 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-22 |
Time |
16:19 |
Sent To |
B |
|
Notes |
2006-05-22 00:00:00 | TO "MJACOBS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-06 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-06 |
Time |
15:24 |
Sent To |
B |
|
Notes |
2006-05-06 00:00:00 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-01 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-01 |
Time |
09:59 |
Sent To |
E |
|
Notes |
2006-05-01 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-17 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-17 |
Time |
12:09 |
Sent To |
B |
|
Notes |
2006-04-17 00:00:00 | TO "MJACOBS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-03 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-03 |
Time |
16:39 |
Sent To |
E |
|
Notes |
2006-04-03 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-23 |
Time |
09:11 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
09:55 |
Sent To |
E |
|
Notes |
2006-02-06 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-28 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-28 |
Time |
17:12 |
Sent To |
Z |
|
Notes |
2006-01-28 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-13 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-13 |
Time |
10:11 |
Sent To |
E |
|
Notes |
2005-09-13 00:00:00 | TO 'E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-09 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-09 |
Time |
14:31 |
Sent To |
Z |
|
Notes |
2005-09-09 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-01 |
Time |
11:55 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-01 |
Time |
11:54 |
Sent To |
G |
|
Notes |
2006-05-01 00:00:00 | REVISION: CHANGED SPA SIZE |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-06 |
Time |
13:30 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-04-06 |
Time |
13:30 |
Sent To |
B |
|
Notes |
2006-04-06 00:00:00 | REVISION: CHANGED SIZE OF SPA |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-09 |
Time |
06:04 |
Rev Time |
1.00 |
Received By |
mperson |
Date |
2006-02-09 |
Time |
06:04 |
Sent To |
B |
|
Notes |
2006-02-09 00:00:00 | REVISION:RELOCATED MAIN DRAINS, AND | | WATER FEATURE. ELIMINATED 2 THERAPY JETS | | AND RELOCATED 2 EXISTING THERAPY JETS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-28 |
Time |
18:19 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-28 |
Time |
18:18 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2006-06-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-04 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-04 |
Time |
09:58 |
Sent To |
I |
|
Notes |
2006-06-04 00:00:00 | REVISION CHANGE OF POOL SIZE. | | NOTE:POOL EQUIPMENT WILL BE 5FT FROM | | PROPERTY LINE. | | | | SEC 94-303 (4) POOL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4FT INTO A SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2006-05-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-05-22 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-05-22 |
Time |
13:52 |
Sent To |
I |
|
Notes |
2006-05-22 00:00:00 | DENIED, | | 1. THE PLANS IS FOR THE ADDRESS 309 | | AVILA, BUT THE SURVEY SHOWS 4101 | | WASHINGTON RD. | | 2. MUST PROVIDE THE CORRECT SURVEY FOR | | THE ADDRESS ON PLANS WITH THE CHANGE IN | | THE POOL SIZE & SETBACKS. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2006-04-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-02 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-02 |
Time |
16:55 |
Sent To |
I |
|
Notes |
2006-04-02 00:00:00 | REVISION - CHANGE IN POOL SIZE (POOL & | | DECK MUST NOT ENCROACH INTO UTILITY | | EASEMENT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-02-03 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-02-03 |
Time |
18:20 |
Sent To |
I |
|
Notes |
2006-02-03 00:00:00 | REVISION - INTERIOR OF THE POOL ONLY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-12 |
Time |
19:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-12 |
Time |
19:57 |
Sent To |
I |
|
Notes |
2005-09-12 00:00:00 | POOL MUST BE A MINIMUM OF 5FT ON THE | | SIDE & REAR. |
|
|