Plan Review Details - Permit 05082088
Plan Review Stops For Permit 05082088
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-01-24 Cont ID  
Sent By alange Date 2006-01-24 Time 16:33 Rev Time 0.50
Received By alange Date 2006-01-24 Time 16:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-12-09 Cont ID  
Sent By alange Date 2005-12-09 Time 15:37 Rev Time 0.50
Received By alange Date 2005-12-09 Time 15:34 Sent To  
Notes
2005-12-09 00:00:00SECOND REVIEW
  ACTION: DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2) PROVIDE INFORMATION FOR THE SLAB
 AND
 ANCHORING OF GENERATOR, SEE1606.1.3
 ANCHORAGE AGAINST OVERTURNING, UPLIFT
 AND SLIDING. STRUCTURAL MEMBERS AND
 SYSTEMS, AND COMPONENTS AND CLADDING
 IN
 ANCHORED TO RESIST WIND-INDUCED
 OVERTURNING, UPLIFT AND SLIDING AND TO
 PROVIDE CONTINUOUS LOAD PATHS FOR
 THESE
 FORCES TO THE FOUNDATION.WHERE A
 PORTION OF THE RESISTANCE TO THESE
 FORCES IS PROVIDED BY DEAD LOAD, THE
 MINIMUM DEAD LOAD LIKELY TO BE IN
 PLACE
 DURING A DESIGN WIND EVENT SHALL BE
 USED.
  
 4. FBC 104.2.1ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPOSIBLE
 FOR THE DESIGN.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-20 Cont ID  
Sent By alange Date 2005-09-20 Time 08:05 Rev Time 0.50
Received By alange Date 2005-09-20 Time 08:05 Sent To  
Notes
2005-09-20 00:00:001ST REVIEW
  ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE
 ISSUED.
  
 2) PROVIDE INFORMATION FOR THE SLAB
 AND
 ANCHORING OF GENERATOR, SEE1606.1.3
 ANCHORAGE AGAINST OVERTURNING, UPLIFT
 AND SLIDING. STRUCTURAL MEMBERS AND
 SYSTEMS, AND COMPONENTS AND CLADDING
 IN
 ANCHORED TO RESIST WIND-INDUCED
 OVERTURNING, UPLIFT AND SLIDING AND TO
 PROVIDE CONTINUOUS LOAD PATHS FOR
 THESE
 FORCES TO THE FOUNDATION.WHERE A
 PORTION OF THE RESISTANCE TO THESE
 FORCES IS PROVIDED BY DEAD LOAD, THE
 MINIMUM DEAD LOAD LIKELY TO BE IN
 PLACE
 DURING A DESIGN WIND EVENT SHALL BE
 USED.
  
 3) SURVEY: FL S S472.025 REQUIRES
 SURVEYSTO BE ORIGINALS, SIGNED, SEALED
 AND DATED.
  
 4 ) FBC 104.2.1ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPOSIBLE
 FOR THE DESIGN.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-23 Cont ID  
Sent By dpalmer Date 2006-01-23 Time 18:53 Rev Time 0.00
Received By dpalmer Date 2006-01-23 Time 18:23 Sent To B
Notes
2006-01-23 00:00:00SIGNAGE REQUIRED PER 702.8, 230.2E

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-12-06 Cont ID  
Sent By dpalmer Date 2005-12-06 Time 07:48 Rev Time 0.00
Received By dpalmer Date 2005-12-06 Time 07:48 Sent To B
Notes
2005-12-06 00:00:00*** UNSAT ***
  
 1)NOTE: PLEASE SUBMIT TWO COMPLETE SETS
 OF PLANS, SPECS/MANUFACTURE CUT SHEETS.
 PLEASE BE SURE ALL PLANS CONTAIN THE
 PRINTED NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR PLANS/ DESIGN.
 FBC 104.2.1 ADMINISTRATIVE SECTION.
  
 2)NOTE: PLEASE SEE PANEL SCHEDULE/LOAD
 CALCULATIONS SUBMITTED INDICATE FOR
 PANEL "A", HOWEVER RISER DIAGRAM SHOWS
 PANEL "B" AS THE EM PANEL?
 PLEASE CORRELATE.
  
  
 3)NOTE: PLEASE SEE LOAD CALCUALTIONS
 EXCEED RATING OF DISCONNECTS FOR
 GENERATOR AND SERVICE.
 PLEASE SEE LOAD FOR PANEL.
 215.5
  
 4)NOTE: PLEASE SEE PERMIT APPLICATION
 HAS NOW BEEN CHANGED BACK TO NATURAL
 GAS, HOWEVER PLEASE SEE SPECS FOR
 GENERATOR INDICATE THIS AS LP?
 PLEASE ALSO VERIFY WHICH, AS GEN IS NOT
 RATED AT 40KW AS NG.
 215.5
  
 ** PLEASE NOTE**
 AUTOMATIC LOAD SHEDDING MAY BE AN
 OPTION.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. PLEASE ALSO BE SURE TO SUBMIT
 "2" SETS OF PLANS TOGETHER.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 ** PLEASE SEE THE NOC SHOWN IS FOR THE
 BLD CONTRACTOR AND FOR THE NEW SFR. A
 SEPARATE NOC WILL BE REQUIRED AS THE NEW
 SFR DOES NOT INCLUDE THE GENERATOR.FS
 713.13(2)
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-09-09 Cont ID  
Sent By dpalmer Date 2005-09-09 Time 20:06 Rev Time 0.00
Received By dpalmer Date 2005-09-09 Time 20:06 Sent To M
Notes
2005-09-09 00:00:00*** UNSAT ****
  
 1)NOTE:
 PLEASE SEE 230.72 FOR GROUPING OF MAINS.
 PLEASE CLARIFY IF EXSITING MCB PANEL IS
 LOCATED IMMEDIATELY AJACENT/CLOSE
 PROXIMITY TO EXISTING PANELS.
 PLEASE SEE 225.31 FOR DISCONNECTING
 MEANS REQUIRED, GROUPED PER 225.34 AND
 RATED FOR SERVICE EQUIPMENT PER 225.36
 PLEASE SEE NO SPECS/MANUFACTURE CUT
 SHEETS WERE SUBMITTED FOR ATS.
 PLEASE SEE THE REQUIRED DISCONNECT FROM
 GEN IS LOCATED ON THE OTHER SIDE OF
 HOUSE, WHICH DOES NOT GROUP MAINS.
  
 2)NOTE:
  
 3)NOTE:
  
 4)NOTE: PLEASE SEELOAD CALCULATIONS
 SUBMITTED. PLEASE SEE 220.31B, NO
 DERATING MAY BE TAKEN FOR AHU/HEAT.
 PLEASE SEE IS IT PERMITTED TO "LOAD
 SHED" HEAT LOADS FROM A/C SYSTEMS
 THROUGH LV CONTACTORS FROM GEN OR ATS.
 220.31,702.5, 90.4,700.5
 PLEASE SEE 700.58, WHICH PERMIT LOAD
 SHEDDING. PLEASE PROVIDE DETAIL IS ANY
 OF THE LV CONTACTS PROVIDE BY ATS OR GEN
 WILL BE USED TO INTERUPT ONE OR MORE
 HEAT CONTROL WIRES.
  
 5)NOTE:
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-19 Cont ID  
Sent By adarroug Date 2006-01-19 Time 11:04 Rev Time 0.00
Received By adarroug Date 2006-01-19 Time 11:04 Sent To E
Notes
2006-01-19 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-28 Cont ID  
Sent By adarroug Date 2005-11-28 Time 11:38 Rev Time 0.00
Received By adarroug Date 2005-11-28 Time 11:38 Sent To E
Notes
2005-11-28 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-08 Cont ID  
Sent By adarroug Date 2005-09-08 Time 15:45 Rev Time 0.00
Received By adarroug Date 2005-09-08 Time 15:45 Sent To E
Notes
2005-09-08 00:00:00TO "GEN-RES" BOX "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 14:46 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 14:46 Sent To Z
Notes
2005-09-01 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-09-14 Cont ID  
Sent By tgordon Date 2005-09-14 Time 16:07 Rev Time 0.20
Received By tgordon Date 2005-09-14 Time 16:07 Sent To P
Notes
2005-09-14 00:00:00*** PROVISO ***
 1) GENERATOR EXHAUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJACENT BUILDING
 OPENINGS. 2001 FBC/M 804.3.3.
 2) NATURAL GAS PIPING REQUIRES A GAS
 PERMIT APPLICATION BY A LICENSE PLUMBING
 CONTRACTOR.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-09-17 Cont ID  
Sent By jleech Date 2005-09-17 Time 13:19 Rev Time 0.00
Received By jleech Date 2005-09-17 Time 13:19 Sent To B
Notes
2005-09-17 00:00:00GAS PERMIT REQUIRED. GAS CONTRACTOR TO
 SUBMIT PERMIT APPLICATION WITH PLANS.
 GAS PERMIT IS REQUIRED TO BE ON JOB AND
 SIGNED OFF BEFORE GEN. FINAL.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-09-07 Cont ID  
Sent By mmclean Date 2005-09-07 Time 19:58 Rev Time 0.00
Received By mmclean Date 2005-09-07 Time 19:58 Sent To I
Notes
***NONE***