Plan Review Stops For Permit 05081654 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-19 |
Time |
13:36 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2005-09-19 |
Time |
13:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-10-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-21 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-10-21 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-14 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2005-10-14 00:00:00 | SPOKE TO CONTRACTOR ON 10/11/05, | | WAITING FOR NEW PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-09-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-09 |
Time |
16:50 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-09-09 |
Time |
16:50 |
Sent To |
M |
|
Notes |
2005-09-09 00:00:00 | **** UNSAT **** | | | | 1)NOTE: PLEASE SEE MAIN DISCONNECT IS | | REQUIRED TO MANUAL AND LOCATED ON THE | | OUTSIDE OF SERVICE EQUIPMENT. | | 230.76,230.79 | | PLEASE SEE 230.72 FOR GROUPING OF MAINS. | | | | 2)NOTE: PLEASE SEE RISER INDICATES AN | | "EQUIPMENT GROUNDING" CONDUCTOR FROM | | METER TO MAIN. 250.6, 250.24 | | PLEASE SEE AN EQUIPMENT GRND IS ONLY | | INSTALLED AFTER THE FIRST MEANS OF | | DISCONNECT. | | | | 3)NOTE: PLEASE SEE SITE/ EQUIPMENT PLANS | | DOES NOT INDICATE LOCATION OF ATS. | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW AND IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-10-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-07 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-07 |
Time |
11:30 |
Sent To |
E |
|
Notes |
2005-10-07 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-07 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-07 |
Time |
11:00 |
Sent To |
E |
|
Notes |
2005-09-07 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-19 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-08-25 |
Time |
08:43 |
Sent To |
|
|
Notes |
2005-08-25 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-16 |
Time |
09:26 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2005-09-16 |
Time |
09:26 |
Sent To |
P |
|
Notes |
2005-09-16 00:00:00 | *** PROVISO *** | | 1) PLANS MUST SHOW ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS). | | 2) GENERATOR EXHAUST MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | TEN FEET AWAY FROM ADJECENT BUILDING | | OPENINGS. 2001 FBC/M 804.3.3 . | | 3) MANUFACTURE'S INSTALLATION | | INSTRUCTIONS MUST BE SUBMITTED WITH | | PERMIT APPLICATION. | | 4) NATURAL GAS PIPING REQUIRES A GAS | | PERMIT APPLICATION BY A LICENSE PLUMBING | | CONTRACTOR. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2005-09-17 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-17 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2005-09-17 |
Time |
12:39 |
Sent To |
B |
|
Notes |
2005-09-17 00:00:00 | NO GAS APPLICATION ON FILE. GAS | | CONTRACTOR TO MAKE APPICATION WITH PLANS | | AND COMPLETE WORK BEFORE FINAL GENERATOR | | INSPECTION. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-06 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-06 |
Time |
17:41 |
Sent To |
I |
|
Notes |
2005-09-06 00:00:00 | GENERATOR CAN ONLY ENCROACH 4FT INTO | | SETBACK. |
|
|