Plan Review Stops For Permit 05081156 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-10-14 |
Time |
08:30 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-10-14 |
Time |
08:30 |
Sent To |
PC |
|
Notes |
2005-10-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05081156 | | ADD: 6650 AUDUBON TRACE | | CONT: MCAFEE ELECTRIC | | TEL: (561)662-2959 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2NDREVIEW | | ACTION:REVIEWED | | | | BUILDING PROVISO: | | | | 1 ) GENERATOR SLAB & ANCHOR REQUIREMENT | | PROVIDE PLANS WITH THE INFORMATION | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | THE DEVICE REQUIRES WITHOUT LOAD | | REDUCTION. THE NEW SLAB AND HOLD DOWN | | DETAILS: 104.2.1* ALL INFORMATION, | | DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | FOR THE DESIGN. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-12 |
Time |
08:53 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-09-12 |
Time |
07:27 |
Sent To |
|
|
Notes |
2005-09-12 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05081156 | | ADD: 6650 AUDUBON TRACE | | CONT: MCAFEE ELECTRIC | | TEL: (561)662-2959 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) HILLMAN ENGINEERING PLAN REQUIRES A | | RAISED & SIGNED SEAL. | | PLANS, SPECIFICATIONS,REPORTS OR | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | RECORD SHALL HAVE THE SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | TO THE DOCUMENT. | | FL STATE STAT: 61G15-23.002 ENGINEERS | | FL ATATE STAT: 61G16.003 ARCHITECTS | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-10-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-05 |
Time |
14:27 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-10-05 |
Time |
14:27 |
Sent To |
M |
|
Notes |
2005-10-05 00:00:00 | *** REDLINED PLANS. | | | | CONDUCTORS FROM ATS TO MCB PANELS TO BE | | MAIN OF 1/0'S, #3' SHOWN. | | NO EQUIPMENT GROUNDING CONDUCTOR FROM | | METER TO ATS/ FIRST MEANS OF DISCONNECT. | | 250.6,250.24 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
07:06 |
Rev Time |
0.70 |
Received By |
dpalmer |
Date |
2005-09-01 |
Time |
07:01 |
Sent To |
M |
|
Notes |
2005-09-01 00:00:00 | ********** UNSAT ************ | | | | | | | | 1)NOTE: PLEASE SUBMIT TWO COPIES OF | | MANUFACTURES SPECS/CUT SHEETS FOR | | GENERATOR AND ATS. | | | | | | 2)NOTE: PLEASE SEE CONDUCTORS FROM METER | | TO ATS. PLEASE SEE THE # OF CONDUCTORS, | | AS IT APPEARS AN "EQUIPMENT GROUNDING | | CONDUCTOR" IS BEING INSTALLED. PLEASE | | SEE 250.6, AN EQP GRNDING CONDUCTOR IS | | ONLY INSTALLED AFTER THE FIRST MEANS OF | | DISCONNECT. PLEASE INDICATE OF THE ATS | | WILL BE THE FIRST MEANS OF DISCONNECT AS | | IT IS SHOWN THIS WAY ON RISER. PLEASE | | SEE 230.76,230.79, THE MEANS OF | | DISCONNECT SAHHL MANUAL AND LOCATED ON | | THE OUTSIDE OF THE EQUIPMENT. | | | | 3)NOTE: PLEASE SEE 225.31 FOR MISSING | | MEANS OF DISCONNECT. PLEASE SEE 225.34 | | FOR GROUPING OF THIS MEANS OF DISCONNECT | | WITH EXISTING MAIN(S). | | PLEASE SEE 225.36, THIS DISCONNECTING | | MEANS SHALL BE LISED AS "SERVICE | | EQUIPMENT". SPECS DO INDICATE THIS FOR | | SERVICE EQUIPMENT RATED. | | | | 5)NOTE: PLEASE SEE 225.35FOR LOADS | | /CALCULATION WHICH IS BEING RE-FED. | | PLEASE SEE LOADS SHALL BE INCREASED AT | | 125%. | | 702.5 | | | | 6)NOTE: PLEASE SEE SIZE OF CONDUCTORS | | INDICATE FOR THE TWO 150A PANELS. PLEASE | | SEE #3 IS RATED FOR 110A'S,310.15B6 | | PLEASE SEE SHEET INDICATES SERVICE AT | | 300A'S. | | | | 7)NOTE: PLEASE BE SURE ALL | | PLANS/DRAWINGS CONTAIN THE PRINTED ANME | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | FOR PLANS/ DESIGN. | | FBC 104.2.1, ADMINISTRATIVE CODE | | CITY-WIDE AMENDMENTS. | | | | 7)NOTE: PLEASE SEE THE VALUATION FOR | | PERMIT APPLICATION SHALL INCLUDE ALL | | LABOR AND MATERIALS EVEN IF MATERIALS | | (GEN) IS OWNER SUPPPLIED. | | 104.6.5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-04 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-04 |
Time |
15:19 |
Sent To |
E |
|
Notes |
2005-10-04 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-30 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-30 |
Time |
13:59 |
Sent To |
E |
|
Notes |
2005-08-30 00:00:00 | TO "GEN-RES" BOX/ "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-19 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-19 |
Time |
08:50 |
Sent To |
Z |
|
Notes |
2005-08-19 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-10-06 |
Time |
08:13 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2005-10-06 |
Time |
08:13 |
Sent To |
B |
|
Notes |
2005-10-06 00:00:00 | *** PROVISO *** | | 1) GENERATOR EXHUST MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | TEN FEET AWAY FROM ADJECENT BUILDING | | OPENINGS. PER 2001 FBC/M 804.3.3 . | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-08 |
Time |
11:04 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-09-08 |
Time |
11:04 |
Sent To |
P |
|
Notes |
2005-09-08 00:00:00 | *** DENIED *** | | 1) PLANS MUST INICATE ANY BUILDING | | OPENINGS (WINDOWS, DOORS, ROOF/EAVE | | VENTS.GENERATOR EXHAUST MUST BE TEN | | FEET AWAY FROM ANY BUILDING OPENINGS, | | AND TEN FEET AWAY FROM ADJACENT | | BUILDING OPENINGS. 2001 FBC/M 804.3.3 | | 2) NATURAL GAS PIPING WILL REQUIRE A | | GAS PERMIT APPLICATION BY A LICENSE | | PLUMBING CONTRACTOR. | | 3) PLEASE SEE ELECTRICAL REVIEW NOTES | | #1 AND "#7" . | | IF YOU HAVE ANY QUESEIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719 . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-09 |
Time |
08:09 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-09 |
Time |
08:09 |
Sent To |
B |
|
Notes |
2005-09-09 00:00:00 | GAS PERMIT REQUIRED. PLUMBING CONTRACTOR | | IS REQUIRED TO MAKE APPLICATION AND | | SUBMIT PLANS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-29 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-29 |
Time |
17:57 |
Sent To |
I |
|
Notes |
|
|