Plan Review Stops For Permit 05081151 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-11-09 |
Time |
11:40 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-11-09 |
Time |
11:40 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-12 |
Time |
07:17 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-09-12 |
Time |
07:16 |
Sent To |
PC |
|
Notes |
2005-09-12 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05081151 | | ADD: 7317 HORIZON DR | | CONT: DANIEL ELECTRICAL | | TEL: (561)718-5324 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | PLANS, SPECIFICATIONS,REPORTS OR | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | RECORD SHALL HAVE THE SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | TO THE DOCUMENT. | | FL STATE STAT: 61G15-23.002 ENGINEERS | | FL ATATE STAT: 61G16.003 ARCHITECTS | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-09 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-11-09 |
Time |
10:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-01 |
Time |
09:00 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-09-01 |
Time |
08:59 |
Sent To |
M |
|
Notes |
2005-09-01 00:00:00 | ********* UNSAT ********* | | | | 1)NOTE: PLEASE SEE COMMENTS FROM OTHER | | REVIEWER(S). BLDG FOR SLAB DETAIL | | SUBMITTED. | | | | 2)NOTE: PLEASE SEE SITE PLAN SUBMITTED | | SHOWS GENERATOR RIGHT NEXT TO HOUSE?? | | PLEASE SHOW SET BACK AND DIMENTIONS FROM | | DWELLING STRUCTURE. | | PLEASE SEE MECH NOTES, MUST BE 10' FROM | | ANY OPENINGS TO HOUSE,ATTIC VENTILATION, | | DOORS AND WINDOWS. | | | | 3)NOTE: PLEASE CORRELATE RISER DIAGRAM | | WITH PANEL SCHEDULES SUBMITTED. | | PLEASE SEE RISER SHOWS 2 PANELS, BOTH | | 200A WITH 2/0'S. PLEASE SEE PANEL "A" | | SHOWN AS 150A W/ #1 AS FEEDERS?? | | PLEASE SEE PANEL "C" IS NOT SHOWN ON | | RISER AND SEE PANEL "B" SHOWS 100A OCP | | ON #6 AWG. PLEASE SEE 240.4,310.16 ETC. | | | | 4)NOTE: PLEASE SEE EQUIPMENT GROUNDING | | CONDUCTOR SHOWN FROM METER TO FIRST | | MEANS OF DISCONNECT. | | PLEASE SEE 250.6, | | | | 5)NOTE: PLEASE SEE EXISTING SERVICE IS | | SHOWN AS 400A, YET NEW MAIN AND ATS | | SHOWN BRINGS SERVICE DOWN TO 300A'S?? | | PLEASE SUBMIT MORE INFORMATION ON NEW | | MAIN SHOWN ON RISER. OCP? ETC | | AIC RATINGS FOR ALL EQUIPMENT BEING | | INSTALLED, MAIN, ATS ETC | | 702.6,110.9 ETC. | | | | 6)NOTE: PLEASE SUBMIT SPEC ON ATS, | | SHEETS SUBMITTED DOES NOT PROVIDE | | INFORMATION FOR RATING PER 225.36, | | 230.70 | | MUST INDICATE BEING RATED AS SERVICE | | EQUIPMENT. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-17 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-17 |
Time |
08:42 |
Sent To |
E |
|
Notes |
2005-10-17 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-25 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-25 |
Time |
10:57 |
Sent To |
E |
|
Notes |
2005-08-25 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-18 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-18 |
Time |
17:45 |
Sent To |
Z |
|
Notes |
2005-08-18 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-11-09 |
Time |
16:38 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-11-09 |
Time |
16:38 |
Sent To |
PC |
|
Notes |
2005-11-09 00:00:00 | MECHANICAL PROVISO: | | GENERATOR EXHAUSST MUST BE 10' AWAY FROM | | ANY BUILDING OPENINGS (WINDOWS, DOORS, | | ROOF/ EAVE VENTS. | | | | NATURAL GAS PIPING WILL REQUIRE A GAS | | PERMIT APPLICATION BY A LICENSED | | PLUMBING CONTRACTOR. | | JIM WITMER | | MECHANICAL PLAN REVIEW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-08 |
Time |
13:30 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2005-09-08 |
Time |
13:30 |
Sent To |
P |
|
Notes |
2005-09-08 00:00:00 | *** DENIDE *** | | 1) GENERATOR EXHAUET MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF/EAVE VENTS), | | AND TEN FEET AWAY FROM ADJACENT | | BUILDING OPENINGS. 2001 FBC/M 804.3.3 | | 2) NATURAL GAS PIPING WILL REQUIRE A | | GAS PERMIT APPLICATION BY A LICENSE | | PLUMBING CONTRACTOR. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-09 |
Time |
08:26 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-09 |
Time |
08:26 |
Sent To |
B |
|
Notes |
2005-09-09 00:00:00 | GAS APP. RECIEVED # 05080241 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-24 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-24 |
Time |
17:09 |
Sent To |
I |
|
Notes |
2005-08-24 00:00:00 | GENERATOR CAN ONLY ENCROACH 4FT INTO | | SETBACK. |
|
|