Plan Review Stops For Permit 05081143 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
N |
Date |
2005-12-02 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2005-12-02 |
Time |
12:49 |
Rev Time |
0.50 |
Received By |
amorse |
Date |
2005-12-02 |
Time |
12:49 |
Sent To |
PC |
|
Notes |
2005-12-02 00:00:00 | | | | | RESTAMPED AND DUPLICATE PEMIT ISSUED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-09-20 |
Time |
12:31 |
Rev Time |
0.25 |
Received By |
mjacobs |
Date |
2005-09-20 |
Time |
12:13 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-09-16 |
Time |
10:23 |
Rev Time |
1.25 |
Received By |
mjacobs |
Date |
2005-09-16 |
Time |
07:34 |
Sent To |
PC |
|
Notes |
2005-09-16 00:00:00 | 1) THE DRAWINGS FOR THE FOOTING DETAIL | | NEEDS TO BE SIGNED/DATED AND SEAL BY THE | | ENGINEER OF RECORD. | | F.A.C. 61G15-23.002. | | | | 2) THE DRAWINGS FOR THE FOOTING DETAIL | | HAS BEEN COPY AND PASTE ON THE NEW | | SHEETS SUBMITTED.HOWEVER, THESE DRAWINGS | | NEEDS THE PRINTED NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DRAWINGS. | | | | 3) THE FOOTING DETAIL STATES A MINIMUM | | PSI OF 2500. THE CONCRETE DETAIL ON THE | | ENGINEERED DRAWINGS STATES 3000 PSI. | | PLEASE CLARIFY THESE TWO DETAILS. | | | | BUILDING PLAN REVIEW | | MYRON JACOBS | | TEL: (561)805-6726 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-09-14 |
Time |
17:36 |
Rev Time |
0.75 |
Received By |
mjacobs |
Date |
2005-09-14 |
Time |
16:54 |
Sent To |
PC |
|
Notes |
2005-09-14 00:00:00 | 1) THE DRAWING FOR THE FOOTING DETAIL | | HAS TO BE SIGNED/DATED AND SEAL BY THE | | ENGINEER. F.A.C. 61G15-23.002 | | | | 2) THE FOOTING DETAIL HAS A MIN OF | | 2500PSI CONCRETE. HOWEVER THE CONCRETE | | DETAIL ON THE SEAL PLANS STATES 3000PSI. | | PLEASE CLARIFY. | | | | BUILDING PLAN REVIEW | | MYRON JACOB | | TEL: (561)805-6726 | | FAX: (561)659-8026 | | [email protected]. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-18 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-18 |
Time |
10:44 |
Sent To |
B |
|
Notes |
2005-11-18 00:00:00 | TO "MJACOBS" DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-20 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-20 |
Time |
11:19 |
Sent To |
B |
|
Notes |
2005-09-20 00:00:00 | TO "MJACOBS" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-15 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-15 |
Time |
15:13 |
Sent To |
B |
|
Notes |
2005-09-15 00:00:00 | TO "MJACOBS" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-31 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-31 |
Time |
09:08 |
Sent To |
B |
|
Notes |
2005-08-31 00:00:00 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-19 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-19 |
Time |
14:47 |
Sent To |
Z |
|
Notes |
2005-08-19 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-08-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-30 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-30 |
Time |
14:01 |
Sent To |
I |
|
Notes |
|
|