Plan Review Details - Permit 05081136
Plan Review Stops For Permit 05081136 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-08-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-23 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-23 |
Time |
14:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-19 |
Time |
07:20 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-08-19 |
Time |
07:20 |
Sent To |
PC |
|
Notes |
2005-08-19 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05081136 | | ADD: 234 VALENCIA RD | | CONT CARLO MERCURIO | | TEL: (561)329-8167 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | ) THIS ROOF IS MISSING OR NOT IN | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | ____ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | ROOF HEIGHT. | | | | ____ CONTRACTOR DID NOT INDICATE THE | | ROOF PITCH. | | | | _X__ CONTRACTOR FAILED TO INDICATE WHICH | | SYSTEM TO BE USED. | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | PRESSURE FOR ZONE _3__ . | | | | _X__ THE SYSTEM PROVIDED STATES | | LIMITATION# 7, SHOULD THE FASTENER | | RESISTANCE BE LESS THAN THAT | | REQUIRED, AS DETERMINED BY THE | | BUILDING OFFICIAL, A REVISED | | FASTENER SPACING, PREPARED , SIGNED | | AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER, REGISTERED | | ARCHITECT OR REGISTERED ROOF | | CONSULTANT MAY BE SUBMITTED. | | | | ___THE SYSTEM PROVIDED INDICATES | | LIMITATION# 9, NO ENHANCED | | FASTENING ALLOWED. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-17 |
Time |
15:30 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-08-17 |
Time |
15:30 |
Sent To |
PC |
|
Notes |
2005-08-17 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05081136 | | ADD: 234 VALENCIA RD | | CONT CARLO MERCURIO | | TEL: (561)329-8167 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | ) THIS ROOF IS MISSING OR NOT IN | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | _X__ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | ROOF HEIGHT. | | | | _X__ CONTRACTOR DID NOT INDICATE THE | | ROOF | | | | PITCH. | | | | _X__ CONTRACTOR FAILED TO INDICATE WHICH | | SYSTEM TO BE USED. | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | PRESSURE FOR ZONE _3__ . | | | | _X__ THE SYSTEM PROVIDED STATES | | LIMITATION# 7, SHOULD THE FASTENER | | RESISTANCE BE LESS THAN THAT | | REQUIRED, AS DETERMINED BY THE | | BUILDING OFFICIAL, A REVISED | | FASTENER SPACING, PREPARED , SIGNED | | AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER, REGISTERED | | ARCHITECT OR REGISTERED ROOF | | CONSULTANT MAY BE SUBMITTED. | | | | ___THE SYSTEM PROVIDED INDICATES | | LIMITATION# 9, NO ENHANCED | | FASTENING ALLOWED. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2005-08-17 00:00:00 | OK PER F MITNER |
|
|
|
Account Summary | Usage Policy | Privacy Policy