Plan Review Details - Permit 05081072
Plan Review Stops For Permit 05081072 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-11-21 |
Time |
17:56 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-11-21 |
Time |
17:56 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-10-04 |
Time |
07:57 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-10-04 |
Time |
07:57 |
Sent To |
PC |
|
Notes |
2005-10-04 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- PERMIT APPLICATION SAYS FOOTER BY | | OTHERS. CONTRACTOR REPLIED BY SAYING | | THAT POOL CONTRACTOR IS DOING THE | | FOOTING. I RESEARCHED THE POOL PERMIT | | AND THERE IS NOT DETAIL FOR FOOTING FOR | | ENCREEN ENCLOSURE. I EVEN RESEARCHED | | THRU THE MAIN HOUSE BUILDING PERMIT AND | | THERE IS NOT INDICATION OR DETAILS FOR | | SCREEN ENCLOSURE FOOTING EITHER. THERE | | IS NOT ENGINEERING DETAILS ANYWHERE FOR | | THIS FOOTING. | | THEREFORE, NEED TO APPLY FOR SEPARATE | | FOOTING PERMIT AND PROVIDE ALL | | SPECIFICATIONS FROM THE DESIGNER | | RESPONSIBLE FOR IT. | | OR, SINCE FOOTERS ARE INCIDENTAL TO THE | | SCOPE OF WORK OF THE SCREEN ENCLOSURE | | CONTRACTOR, THEN, SUCH CONTRACTOR MAY | | INCLUDE THIS WORK IN THE APPLICATION AND | | REVISE VALUATION FEE ACCORDINGLY. | | DRAWINGS AND SPECIFICATIONS FOR FOOTINGS | | ARE STILL REQUIRED. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC | | 2001. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-19 |
Time |
14:57 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2005-09-19 |
Time |
14:57 |
Sent To |
PC |
|
Notes |
2005-09-19 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- DRAWING IN SCREEN ENCLOSURE | | BEAM-COLUMN CALCULATOR DOESN'T MATCH | | LAYOUT SHOWN ON SHEET 1 OF 1. SEE | | DIMENSIONS AND SHAPE OF SCREEN | | ENCLOSURE. | | | | 3- REVISE LOADS SHOWN ON CALCULATOR | | SHEET. DESIGN LOAD TO BE 10PSF MIN.AS | | REQUIRED BY SEC. 2002.4 FBC 2001. | | | | 4- MISSING SHEET 2 OF 2 OF MASTER PLANS. | | NEED SPAN TABLES TO VERIFY COLUMN AND | | BEAM SPAN. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 5- SHEET 1 OF 2 OF MASTER PLAN SAYS THAT | | "MAX ROOF SPAN=38'-0". CLARIFY AS | | REQUIRED. SEE DIMENSIONS ON PROPOSED | | LAYOUT. | | | | 6- PROVIDE DETAILS AND SPECIFICATIONS | | FOR FOOTING TO SUPPORT THE SCREEN | | ENCLOSURE. | | | | 7- PERMIT APPLICATION SAYS FOOTER BY | | OTHERS. WHO'S DOING THE FOOTING. IS IT | | GOING TO BE SEPARATE PERMIT? | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-18 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-18 |
Time |
15:06 |
Sent To |
B |
|
Notes |
2005-11-18 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-29 |
Time |
18:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-29 |
Time |
18:45 |
Sent To |
B |
|
Notes |
2005-09-29 00:00:00 | TO "JGOMEZ' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-29 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-29 |
Time |
09:00 |
Sent To |
B |
|
Notes |
2005-08-29 00:00:00 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-17 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-17 |
Time |
09:54 |
Sent To |
Z |
|
Notes |
2005-08-17 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-08-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-23 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-23 |
Time |
17:56 |
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |