Plan Review Details - Permit 05080654
Plan Review Stops For Permit 05080654
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-31 Cont ID  
Sent By alange Date 2005-08-31 Time 13:10 Rev Time 2.75
Received By alange Date 2005-08-31 Time 09:32 Sent To  
Notes
2005-08-31 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SQUARE FOOTAGE ON PLANS SHOULD SHOW
 ROOM ADDITIONS AS NEW SPACE BOTH A/C AND
 NON A/C SPACE.THIS IS NEEDED FOR OUR
 PRICING CALCULATIONS AND IMPACT FEE
 CALCULATIONS.
  
 4.BUILDING VALUATION IS $30,000 IS TOO
 LOW.BASED ON THE ROOM ADDITION ALONE
 THE VALUE WILL BE OVER $110,000.00.
 PLUS THE CARPORT CONVERSION AND ALL
 OTHER WORK.RE-ADJUST PERMIT VALUE AND
 PAY ADDITIONAL PERMIT FEES.
 IF AN APPROPRIATE PRICE ADJUSTMENT IS
 NOT MADE WE WILL ADJUST IT ACCORDING TO
 SBCCI BUILDING VALUATION DATA AND
 MARSHALL AND SWIFT ESTIMATING GUIDE.
  
 5.SUBMIT A STAIRWAY STRUCTURAL DETAIL.
  
 6.SECOND FLOOR MASTER BEDROOMWINDOWS
 SH-25 DO NOT MEET EGRESS REQUIREMENTS.
 FBC 1005.4.4
  
 7.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS WITH QUALITY ASSURANCE FOR THE
 FOLLOWING:FIXED GLASS WINDOWS,
 SKYLIGHTS, LINTELS AND STRAPS AND
 TIE-DOWNS.
  
 8.ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVALS ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 9.SUBMIT TWO COPIES OF A CURRENT
 SIGNED AND SEALED SURVEY SHOWING
 EXISTING STRUCTURE AND ROOM ADDITIONS.
  
 10.SHOW HAND RAILS ON STAIRS COMPLYING
 WITH FBC 1007.5.1
  
 11.STAIRS AND INTERMEDIATE LANDINGS
 SHALL CONTINUE WITH NO DECREASE IN WIDTH
 ALONG THE DIRECTION OF EGRESS TRAVEL.
 FBC 1007.4.2
  
 12.SHOW ROOF FRAMING DETAILS INCLUDING
 BRACING AND LOADS PER FBC CHAPTER 16.
  
 13.SHOW THE MINIMUM FOOTING DEPTH OF
 12".FBC 1804.1.3
  
 14.FBC 3401.7.2.6 WHEN REPAIRS AND
 ALTERATIONS AMOUNTING TO MORE THAN 50
 PERCENT OF THE VALUE OF THE EXISTING
 BUILDING ARE MADE DURING ANY 12 MONTH
 PERIOD, THE BUILDING OR STRUCTURE SHALL
 BE MADE TO CONFORM TO THE
 REQUIREMENTS FOR A NEW BUILDING OR
 STRUCTURE OR BE ENTIRELY DEMOLISHED.
 SHOW HOW COMPLIANCE WILL BE MADE WITH
 THIS SECTION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-08-15 Cont ID  
Sent By btrobaug Date 2005-08-15 Time 15:05 Rev Time 0.50
Received By btrobaug Date 2005-08-15 Time 14:03 Sent To P
Notes
2005-08-15 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} CIRCUITS 22,24,26,27 & 28 IN PANEL
 "A", CIRCUITS 29,30,33,34,35 AND 36 IN
 PANEL "B" HAVE #14 WIRE ON A 20 AMP
 BREAKER IN VIOLATION OF 310.16 AND
 240.4(D).
  
 2} BATH RECEPTACLES MUST COMPLY WITH
 210.11(C)(3), 20 AMP(#12). INDICATE SAME
 ON THE PANEL SCHEDULE.
  
 3} INDICATE THE LOCATION OF THE SERVICE
 DISCONNECT ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-11 Cont ID  
Sent By adarroug Date 2005-08-11 Time 16:43 Rev Time 0.00
Received By adarroug Date 2005-08-11 Time 16:43 Sent To E
Notes
2005-08-11 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-08-31 Cont ID  
Sent By alange Date 2005-08-31 Time 13:10 Rev Time 0.00
Received By alange Date 2005-08-11 Time 16:30 Sent To  
Notes
2005-08-11 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-08-30 Cont ID  
Sent By prafter Date 2005-08-30 Time 10:29 Rev Time 1.00
Received By prafter Date 2005-08-30 Time 10:29 Sent To B
Notes
2005-08-30 00:00:00MECH. PLAN REVIEW:
  
  
 1. PLAN SHOWS R/A FROM EXISTING
 BEROOMS, FIRST FLOOR TO CONNECT TO
 SUPPLY AIR.
  
 2.MASTER BATH ROOM REQUIRE EXHAUST FAN
 IN TUB/SHOWER AREA.2003 FBC/M 402.3.1
 BATHROOM.
 PLEASE CORRECT A/C DRAWING AND
 RESUBMIT.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-08-22 Cont ID  
Sent By jleech Date 2005-08-22 Time 09:05 Rev Time 0.33
Received By jleech Date 2005-08-22 Time 09:05 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-08-11 Cont ID  
Sent By mmclean Date 2005-08-11 Time 16:39 Rev Time 0.00
Received By mmclean Date 2005-08-11 Time 16:39 Sent To I
Notes
2005-08-11 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE LOCATION OF THE WORK WITH
 SETBACKS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720