Plan Review Details - Permit 05080590
Plan Review Stops For Permit 05080590
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-11-18 Cont ID  
Sent By jgomez Date 2005-11-18 Time 12:42 Rev Time 1.00
Received By jgomez Date 2005-11-18 Time 12:42 Sent To PC
Notes
2005-11-18 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS AND 8'-0" HIGH 1 HR FIRE
 RATED INSWING DOOR FOR ATRIUM UNDER A
 SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-11-18 Cont ID  
Sent By jgomez Date 2005-11-16 Time 15:52 Rev Time 1.00
Received By jgomez Date 2005-11-16 Time 15:52 Sent To  
Notes
2005-11-16 00:00:0011-15-05 CALLED ANDY TO SUBMIT THE
 CORRECT ENERGY CALCULATIONS (2001) TO
 PROCEED WITH PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-14 Cont ID  
Sent By jgomez Date 2005-09-14 Time 14:27 Rev Time 2.00
Received By jgomez Date 2005-09-14 Time 14:27 Sent To PC
Notes
2005-09-14 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- ENERGY CALCS ARE GETTING THE CEILING
 FANS CREDIT. NEED TO SPECIFY CEILING
 SIZES IN THE ELECTRICAL PLAN, INCLUDING
 FANS REQUIRED IN THE GREAT ROOM. SEE
 TABLE 6-6 CHAPTER 13 FBC 2001.
  
 3- ROOF FRAMING PLAN NEEDS TO BE REVISED
 AT ENTRY PORCH AREA. CONCRETE BEAM
 DOESN'T EXTEND ALL THE WAY BACK TO THE
 FOYER AREA. ALSO, REVISE THE KNEEWALL AT
 THE LEFT HAND SIDE OF THE PORCH ROOF.
 IT'S NOT CONCRETE BEAM EITHER. SEE PLANS
 AND REVISE FRAMING PLAN AS REQUIRED AND
 SPECIFY CORRESPONDING CONNECTORS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 4- TRUSS ANCHOR SCHEDULE. REVISE NUMBER
 OF NAILS FOR HUS26. SEE 2005 CATALOGUE.
  
 5- PROVIDE FLORIDA/LOCAL PRODUCT
 APPROVAL FOR:
 A) INSWING 1HR FIRE RATED DOOR AS SHOWN
 IN PLANS. SEE ATRIUM.
 B) WINDOW MULLION SPECIFIED FOR FIXED
 WINDOWS AT GREAT ROOM AREA.
 C) FIXED WINDOWS: NEED FLORIDA APPROVAL.
 D) SINGLE HUNG WINDOWS. NEED FL APPROVAL
 E) ROOF TILE. NEED FLORIDA APPROVAL.
  
 6- SPECIFY SIZE AND ANCHORS FOR WINDOW
 MULLION AT FIXED WINDOWS IN THE GREAT
 ROOM. MULLION SPECIFIED IN THE WINDOW
 SCHEDULE DON'T RESIST THE DESIGN
 PRESSURES. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-10 Cont ID  
Sent By dpalmer Date 2006-02-10 Time 07:06 Rev Time 0.00
Received By dpalmer Date 2006-02-09 Time 21:05 Sent To PC
Notes
2006-02-10 00:00:00REDLINED:
  
  
 250.52A5 GRND ROD SHALL BE A MIN OF 8'
  
 VIF OCP FOR CU, SHOWS 9.8KW ON 40A OCP

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-08-15 Cont ID  
Sent By dpalmer Date 2005-08-15 Time 20:38 Rev Time 0.20
Received By dpalmer Date 2005-08-15 Time 20:31 Sent To M
Notes
2005-08-15 00:00:00NOTED 210.52C1
  
 PLANS STAMPED.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-02-03 Cont ID  
Sent By adarroug Date 2006-02-03 Time 15:29 Rev Time 0.00
Received By adarroug Date 2006-02-03 Time 15:29 Sent To E
Notes
2006-02-03 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-01 Cont ID  
Sent By adarroug Date 2006-02-01 Time 18:04 Rev Time 0.00
Received By adarroug Date 2006-02-01 Time 18:04 Sent To E
Notes
2006-02-01 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-08 Cont ID  
Sent By adarroug Date 2005-11-08 Time 09:09 Rev Time 0.00
Received By adarroug Date 2005-11-08 Time 09:09 Sent To B
Notes
2005-11-08 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-12 Cont ID  
Sent By adarroug Date 2005-08-12 Time 08:35 Rev Time 0.00
Received By adarroug Date 2005-08-12 Time 08:35 Sent To E
Notes
2005-08-12 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-14 Cont ID  
Sent By jgomez Date 2005-09-14 Time 14:48 Rev Time 0.00
Received By jgomez Date 2005-08-10 Time 18:17 Sent To  
Notes
2005-08-10 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-08-16 Cont ID  
Sent By prafter Date 2005-08-16 Time 08:04 Rev Time 0.50
Received By prafter Date 2005-08-16 Time 08:04 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-08-17 Cont ID  
Sent By jleech Date 2005-08-17 Time 07:43 Rev Time 0.00
Received By jleech Date 2005-08-17 Time 07:43 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-11 Cont ID  
Sent By mmclean Date 2005-08-11 Time 18:13 Rev Time 0.00
Received By mmclean Date 2005-08-11 Time 18:13 Sent To I
Notes
***NONE***