Plan Review Details - Permit 05080587
Plan Review Stops For Permit 05080587
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-11-21 Cont ID  
Sent By jgomez Date 2005-11-21 Time 16:21 Rev Time 0.50
Received By jgomez Date 2005-11-21 Time 16:21 Sent To PC
Notes
2005-11-21 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS AND 1 HR FIRE RATED
 ATRIUM DOOR AS SHOWN ON PLANS UNDER A
 SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-11-21 Cont ID  
Sent By jgomez Date 2005-11-15 Time 18:31 Rev Time 1.00
Received By jgomez Date 2005-11-15 Time 18:31 Sent To  
Notes
2005-11-15 00:00:00CALLED ANDY TO GET THE CORRECT ENERGY
 CALCULATIONS. FBC 2001 FORM. WAITING FOR
 CORRECT CALCS TO PROCEED WITH PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-13 Cont ID  
Sent By jgomez Date 2005-09-13 Time 16:51 Rev Time 2.00
Received By jgomez Date 2005-09-13 Time 16:51 Sent To PC
Notes
2005-09-13 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- ENERGY CALCS ARE GETTING THE CEILING
 FAN CREDIT. NEED TO SPECIFY CEILING
 SIZES IN THE ELECTRICAL PLAN, INCLUDING
 FANS REQUIRED AT GREAT ROOM. SEE TABLE
 6-6 CHAPTER 13 FBC 2001.
  
 3- ROOF FRAMING PLAN NEEDS TO BE REVISED
 AT ENTRY PORCH AREA TO MATCH FOUNDATION
 AND FLOOR PLAN. CONCRETE BEAM DOESN'T
 EXTEND ALL THE WAY BACK TO THE FOYER.
 CONCRETE BEAM IS ONLY AT ENTRY PORCH
 AREA. REVISE ROOF FRAMING PLAN AS
 REQUIRED AND SPECIFY CORRESPONDING
 CONNECTORS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 4- TRUSS ANCHOR SCHEDULE: REVISE NUMBER
 OF NAILS SPECIFIED FOR CONNECTOR HUS26.
 SEE 2005 CATALOGUE.
  
 5- ONE HR FIRE RATED DOOR AT ATRIUM
 PRODUCT APPROVAL SUBMITTED IS FOR
 OUTSWING DOOR. PLANS SHOW INSWING DOORS.
 REVISE AS REQUIRED.
  
 6- SPECIFY MULLION SIZE AND ANCHORS FOR
 FIXED WINDOWS AT GREAT ROOM. SIZE OF
 MULLION SPECIFIED ON WINDOW SCHEDULE
 DOESN'T RESIST THE CALCULATED DESIGN
 PRESSURES. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 7- PROVIDE PRODUCT APPROVAL FOR WINDOW
 MULLION SIZE AS SPECIFIED ABOVE.
  
 8- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL (FLORIDA APPROVAL WAS NOT
 SUBMITTED) FOR:
 A) ROOF TILE.
 B) SINGLE HUNG WINDOWS.
 C) FIXED WINDOWS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-10 Cont ID  
Sent By dpalmer Date 2006-02-10 Time 07:23 Rev Time 0.00
Received By dpalmer Date 2006-02-10 Time 07:16 Sent To PC
Notes
2006-02-10 00:00:00REDLINED:
  
  
 250.52A5 GRND ROD SHALL BE A MIN OF 8'
  
 VIF OCP FOR CU, SHOWS 9.8KW ON 40A OCP

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-08-16 Cont ID  
Sent By dpalmer Date 2005-08-16 Time 21:11 Rev Time 0.25
Received By dpalmer Date 2005-08-16 Time 21:11 Sent To M
Notes
2005-08-16 00:00:00NOTED 210.52C1
  
 ELECTRICAL PLANS STAMPED.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-08 Cont ID  
Sent By adarroug Date 2005-11-08 Time 14:34 Rev Time 0.00
Received By adarroug Date 2005-11-08 Time 14:34 Sent To B
Notes
2005-11-08 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-16 Cont ID  
Sent By adarroug Date 2005-08-16 Time 15:38 Rev Time 0.00
Received By adarroug Date 2005-08-16 Time 15:38 Sent To E
Notes
2005-08-16 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-13 Cont ID  
Sent By jgomez Date 2005-09-13 Time 17:40 Rev Time 0.00
Received By jgomez Date 2005-08-10 Time 18:20 Sent To  
Notes
2005-08-10 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-08-23 Cont ID  
Sent By prafter Date 2005-08-23 Time 08:01 Rev Time 0.50
Received By prafter Date 2005-08-23 Time 08:01 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-08-20 Cont ID  
Sent By jleech Date 2005-08-20 Time 08:09 Rev Time 0.25
Received By jleech Date 2005-08-20 Time 08:09 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-11 Cont ID  
Sent By mmclean Date 2005-08-11 Time 17:59 Rev Time 0.00
Received By mmclean Date 2005-08-11 Time 17:59 Sent To I
Notes
***NONE***