Plan Review Details - Permit 05080390
Plan Review Stops For Permit 05080390
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-09-07 Cont ID  
Sent By alange Date 2005-09-07 Time 13:03 Rev Time 0.50
Received By alange Date 2005-09-07 Time 13:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-08-24 Cont ID  
Sent By alange Date 2005-08-24 Time 13:42 Rev Time 0.33
Received By alange Date 2005-08-24 Time 13:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-09-19 Cont ID  
Sent By dpalmer Date 2005-09-19 Time 15:47 Rev Time 1.00
Received By dpalmer Date 2005-09-19 Time 15:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-09-03 Cont ID  
Sent By dpalmer Date 2005-09-03 Time 11:39 Rev Time 0.50
Received By dpalmer Date 2005-09-03 Time 11:39 Sent To M
Notes
2005-09-03 00:00:00************* UNSAT ***********
  
 1)NOTE: PLEASE SEE PLANS INDICATE
 RE-FEEDING THE ENTIRE SERVICE. PLEASE
 PROVIDE LOADS CALCULATIONS PER 220.31B
  
  
 PLEASE SEE SPECS INDICATE THIS UNIT
 RATED 167A'S WITH LP AS THE PRIME MOVER.
 PLEASE SEE NATURAL GAS IS BEING USED AND
 GENERATED IS NOT RATED FOR THE SAME
 AMERAGE.
 PLEASE PROVIDE LOAD CALCS AS ABOVE FOR
 INTENDED LOADS.
 PLEASE KNOW, IF AUTOMATIC LOAD SHEEDING
 OF "HEAT" ON A/C SYSTEMS IS
 NOTED/DETAILED AND PROVIDE. HEAT LOAD
 AND AND ANY OTHER "SHEDDED" ITEMS MAY BE
 REMOVED FROM LOAD CACULATIONS.
 215.5,700.5, 702.5
  
 2)NOTE: PLEASE SEE GEN SPEC SHEETS
 SUBMITTED SHOWS ARROW TO 40KW UNIT,
 HOWEVER NG CIRCILED FOR 30KW ALSO?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-08-18 Cont ID  
Sent By btrobaug Date 2005-08-18 Time 14:13 Rev Time 0.50
Received By btrobaug Date 2005-08-18 Time 14:04 Sent To M
Notes
2005-08-18 00:00:00 
 PLEASE SUBMIT A SITE PLAN INDICATING THE
 LOCATION OF ALL SERVICE AND GENERATOR
 EQUIPMENT SO THAT COMPLIANCE WITH 225.31
 THROUGH 225.37 CAN BE DETERMINED.
  
 THE RISER DIAGRAM IS INCOMPLETE.(UNLESS
 THE TRANSFER SWITCH IS ALSO THE PANEL).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-15 Cont ID  
Sent By adarroug Date 2005-09-15 Time 16:46 Rev Time 0.00
Received By adarroug Date 2005-09-15 Time 16:46 Sent To E
Notes
2005-09-15 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 16:45 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 16:45 Sent To E
Notes
2005-09-01 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-17 Cont ID  
Sent By adarroug Date 2005-08-17 Time 09:12 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 09:12 Sent To E
Notes
2005-08-17 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-08-24 Time 16:45 Rev Time 0.00
Received By adarroug Date 2005-08-09 Time 09:28 Sent To  
Notes
2005-08-09 00:00:00TO "G" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-09-07 Cont ID  
Sent By prafter Date 2005-09-07 Time 11:16 Rev Time 0.75
Received By prafter Date 2005-09-07 Time 11:16 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-08-24 Cont ID  
Sent By prafter Date 2005-08-24 Time 10:29 Rev Time 1.50
Received By prafter Date 2005-08-24 Time 10:29 Sent To B
Notes
2005-08-24 00:00:00MECH. PLAN REVIEW:
  
 1. GENERATOR MANF. RECOMBINATIONS FOR
 SERVICE CLEARANC /VENILATION IN
 FEET/INCHES IN ALL DIRECTION MUST ACCOM.
 GENERATOR PERMIT APP.NEC 70 110.3 B.
  
 2.GENERATOR EXHAUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENING, AND
 EXHAUST MUST BE DIRECTED AWAY FROM
 BUILDING.AND BE TEN FEET FROM PROPETY
 LINE.2001 FBC/M 804.3.3 TERMINATION.
 2001 FBC/M SECTION 915 8.2.3.2
 EXHAUST SYSTEM TERMINATION.
  
 3. LP/NAT GAS REQUIRES PERMIT, FROM
 LICENSED GAS CONTRACTOR.
  
 PAT RAFTER 561/805/6728 OR 805/6719
 PATTY KRAUSS.
  
 PLEASE CALL IF THEAR ANY QUESTIONS.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-08-13 Cont ID  
Sent By jleech Date 2005-08-13 Time 13:45 Rev Time 0.00
Received By jleech Date 2005-08-13 Time 13:45 Sent To Z
Notes
2005-08-13 00:00:00PERMIT FOR NATURAL GAS REQUIRED BEFORE
 FINAL INSPECTION ON GENERATOR.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-16 Cont ID  
Sent By mmclean Date 2005-08-16 Time 16:26 Rev Time 0.00
Received By mmclean Date 2005-08-16 Time 16:26 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved