Plan Review Details - Permit 05080349
Plan Review Stops For Permit 05080349 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-08 |
Time |
09:47 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2005-09-08 |
Time |
09:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
07:25 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-08-28 |
Time |
07:25 |
Sent To |
PC |
|
Notes |
2005-08-28 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05080349 | | ADD: 114 GOLF AVE | | CONT: SUNRISE ROOFING | | TEL: (561)963-9955 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 3RDREVIEW | | ACTION: DENIED | | 1) THIS ROOF IS MISSING OR NOT IN | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | ___ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | ROOF HEIGHT. | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF | | PITCH. | | | | ___ CONTRACTOR FAILED TO INDICATE WHICH | | SYSTEM TO BE USED. | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | PRESSURE FOR ZONE3___ . | | MAXIMUM DESIGN PRESSURE: REFER TO | | TILE MANUFACTURER'S NOA> | | | | _X__ THE SYSTEM PROVIDED STATES | | LIMITATION# 7, SHOULD THE FASTENER | | RESISTANCE BE LESS THAN THAT | | REQUIRED, AS DETERMINED BY THE | | BUILDING OFFICIAL, A REVISED | | FASTENER SPACING, PREPARED , SIGNED | | | | AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER, REGISTERED | | ARCHITECT OR REGISTERED ROOF | | CONSULTANT MAY BE SUBMITTED. | | | | ___THE SYSTEM PROVIDED INDICATES | | LIMITATION# 9, NO ENHANCED | | FASTENING ALLOWED. | | | | __X__ THE FLAT ROOF SYSTEM HIGHLIGHTED | | IS : SYSTEM TYPE E-2 RUBEROID TILE | | | | UNDERLAYMENT. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-08-09 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-08-09 |
Time |
15:32 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)DIFFERENT PARTS OF DIFFERENT | | APPROVED ASSEMBLIES WERE HIGHLIGHTED. | | CHOOSE ONE APPROVED ASSEMBLY FOR THE | | FLAT DECK. | | | | 2.)INCLUDE THE MEAN ROOF HEIGHT AND | | THE DECK TYPE ON THE APPLICATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-08-05 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-08-05 |
Time |
14:59 |
Sent To |
|
|
Notes |
2005-08-05 00:00:00 | DENIED | | | | 1) SPECIFY WHICH ONE OF THE APPROVED | | ASSEMBLIES LISTED IN THE PRODUCT | | APPROVAL WILL BE INSTALLED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-18 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-18 |
Time |
16:17 |
Sent To |
B |
|
Notes |
2005-08-18 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-09 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-09 |
Time |
14:44 |
Sent To |
B |
|
Notes |
2005-08-09 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |