Plan Review Details - Permit 05080141
Plan Review Stops For Permit 05080141 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-17 |
Time |
13:23 |
Rev Time |
0.44 |
Received By |
jwitmer |
Date |
2005-08-17 |
Time |
07:33 |
Sent To |
PC |
|
Notes |
2005-08-17 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05080141 | | ADD: 1555 PALM BEACH LAKES BLVD | | CONT:ANDREW'S ROOFING | | TEL: (561) 688-1066 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) THIS BUILDING IS A HIGH RISE! PROVIDE | | A SITE PLAN INDICATING WHERE ON THIS | | BUILDING THIS SYSTEM IS TO BE USED. | | | | 2) FROM PREVIOUS REVIEW, SPECIFY THE | | DECK MATERIAL, ANSWER IS " 5/8" CDX | | PLYWOOD SHEATHING BY OTHERS OVER | | EXISTING, NO PERMIT HAS BEEN APPPLIED | | FOR FOR THIS WORK. PROVIDE WHERE THIS | | WORK IS TO OCCUR, THIS IS A TYPEII | | BUILDING WHERE NO PLYWOODSHEATHING IS TO | | BE USED. IS THIS THE AREA OF GREENHOUSE | | LOCATED ON THE FIRST FLOOR? IF SO WHAT | | MATERIAL WIL MAKE UP THE ROOF DECK? | | | | 3) THIS BUILDING BEING A HIGH RISE THE | | NEGATIVE PRESSURES ARE TAKEN FROM THE | | ROOF HEIGHT, ENGINEERED SYSTEM SHOWING | | ZONES 1,2 & 3. | | | | 4) SINCE THIS BUILDING REQUIRES A 1HR | | RATED ROOF ASSEMBLY PROVIDE HOW THIS | | COMPLIANCE WILLBE ACHIEVED. | | | | 5)THE SUBMITTED ROOF REPORT HAS LOW | | PRESSURES FOR END ZONE. TO BE AN | | ENGINEERED SYSTEM. | | | | 6) 1507.5 METAL ROOF PANELS SLOPE | | MINIMUM OF A 3:12 SLOPE. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-08-03 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-08-03 |
Time |
16:43 |
Sent To |
|
|
Notes |
2005-08-03 00:00:00 | DENIED | | | | 1) SPECIFY WHICH ONE OF THE APPROVED | | ASSEMBLIES FROM THE PRODUCT APPROVAL | | WILL BE INSTALLED. | | | | 2) SPECIFY THE MEAN ROOF HEIGHT OF THE | | STRUCTURE. | | | | 3) SPECIFY THE DECK MATERIAL. | | | | 4) ROOF PITCH SPECIFIED ON THE | | APPLICATION IS 1:12, THE MINIMUM SLOPE | | ALLOWED FOR THIS PRODUCT IS 2:12. | | | | 5) SUBMIT SIGNED AND SEALED CALCULATIONS | | FROM A FLORIDA RESISTERED ENGINEER | | INDICATING THE REQUIRED DESIGN PRESSURES | | FOR THE ROOF OF THE STRUCTURE. | | | | 6) SUBMIT SIGNED AND SEALED CALCULATIONS | | FROM A FLORIDA REGISTERED ENGINEER FOR | | INCREASED DESIGN PRESSURES. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
|