Plan Review Stops For Permit 05080028 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-02 |
Time |
10:27 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2005-12-02 |
Time |
10:27 |
Sent To |
|
|
Notes |
2005-12-02 00:00:00 | FOOTING REVISION OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-22 |
Time |
07:56 |
Rev Time |
1.25 |
Received By |
alange |
Date |
2005-09-21 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-08-18 |
Time |
15:18 |
Rev Time |
2.25 |
Received By |
alange |
Date |
2005-08-18 |
Time |
11:15 |
Sent To |
|
|
Notes |
2005-08-18 00:00:00 | DENIED | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.SHOW BEDROOM #2 EGRESS COMPLYING | | WITH 1005.4. | | | | 3.SUBMIT PRODUCT APPROVALS WITH | | QUALITY ASSURANCE FOR THE FOLLOWING: | | SHUTTERS, SKYLIGHTS LINTELS AND | | TIE-DOWNS. | | | | 4.ALL PRODUCT APPROVALS SUBMITTED | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | APPROVAL ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 5.SHOW FOOTING DETAILS COMPLYING WITH | | FBC 1804.1.3SHOW ALSO FINISHED FLOOR | | ELEVATIONS. | | | | 6.STRUCTURAL NOTES #4.IF ENGINEER IS | | NOT RESPOSIBLE FOR ALL NEW STRUCTURAL | | ITEMS ON THIS PLAN PLEASE HAVE PERSON | | RESPOSIBLE FOR THE DESIGN PRINT NAME, | | SIGN AND DATE PLANS FBC 104.2.1 | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-06 |
Time |
10:46 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-06-06 |
Time |
08:45 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-09-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
16:11 |
Rev Time |
0.40 |
Received By |
dpalmer |
Date |
2005-09-10 |
Time |
16:04 |
Sent To |
P |
|
Notes |
2005-09-10 00:00:00 | ********** PROVISO/ REVISION ********* | | | | 1)NOTE: PLEASE SEE FBC CHAPTER 34 | | 3401.7.1.2.1 WHICH REQUIRES ADDITIONS IN | | AN R-3 OCCUPANCY OF 25% OR MORE TO BRING | | ALL SMOKE DETECTORS AND LOCATIONS FOR | | GFI RECEPTS UP TO THE CURRENT CODES. | | 210.8,1-7 AND NFPA-7211.5.1.1 | | | | PLEASE SUBMIT REVISED PLANS BEFORE ROUGH | | ELECTRICAL INSPECTIONS. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-08-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-08-11 |
Time |
09:56 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-08-11 |
Time |
08:55 |
Sent To |
P |
|
Notes |
2005-08-11 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PLEASE SHOW FOOTER STEEL AS PART OF | | THE GEC SINCE IT WILL BE AVAILABLE PER | | 250.50. ALSO SEE 230.70 CWPB AMMENDMENTS | | FOR DISCONNECT REQUIREMENT. | | | | 2} LIST THE BATH GFI AS REQUIRED BY | | 210.11(C)(3), ON THE PANEL SCHEDULE. | | | | 3} THE PERSON RESPONSIBLE FOR THE DESIGN | | SHALL PPRINT AND SIGN NAME ON SAME PER | | 104.2.1 FBC. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-05 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-05 |
Time |
14:16 |
Sent To |
E |
|
Notes |
2006-06-05 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-11-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-23 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-23 |
Time |
16:07 |
Sent To |
B |
|
Notes |
2005-11-23 00:00:00 | TO "ALANGE"DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-08 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-08 |
Time |
09:44 |
Sent To |
E |
|
Notes |
2005-09-08 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-10 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-10 |
Time |
09:48 |
Sent To |
E |
|
Notes |
2005-08-10 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-08-18 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-08-01 |
Time |
11:32 |
Sent To |
|
|
Notes |
2005-08-01 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-08-16 |
Time |
09:28 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-08-16 |
Time |
09:28 |
Sent To |
B |
|
Notes |
2005-08-16 00:00:00 | 1. MECHANICAL CONTRACTOR WILL NEED TO | | SUBMIT MECHANICAL PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-21 |
Time |
08:13 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-21 |
Time |
08:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-08-12 |
Time |
10:14 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-08-12 |
Time |
10:14 |
Sent To |
M |
|
Notes |
2005-08-12 00:00:00 | DENIED; | | 1.PAGE E-1 HAS NOT BEEN SIGNED. (SEE | | ELECTRICAL NOTE 3) | | 2.W/M AND L/T CANNOT CONNECT WITH A | | SANITARY CROSS. FBC-2001 PLUMBING SEC. | | 706.3. INSTALL L/T ABOVE W/M OUTLET. | | 3.A CLEANOUT IS REQUIRED ON W/M STACK AT | | 48" ABOVE FINISH FLOOR, SHOW ON PLANS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-11 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-11 |
Time |
16:18 |
Sent To |
P |
|
Notes |
2005-08-11 00:00:00 | APPROVED BY SHIRLEY GRAHAM, RETURNED TO | | PLUMBING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-09 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-09 |
Time |
16:39 |
Sent To |
I |
|
Notes |
2005-08-09 00:00:00 | DENIED, | | 1. SITEPLAN MUST SHOW THE ADDRESS OF THE | | PROPERTY (THIS WILL INDICATE THE FRONT | | OF THE PROPERTY). | | 2. MUST SHOW THE SIDE & REAR SETBACK OF | | THE STRUCTURE FROM PROPERTY LINE. | | 3. MUST PROVIDE TWO COPY OF UPDATED | | SURVEY SHOWING THE EXISTING STRUCTURE & | | SETBACKS. | | 4. NEW CARPORT MUST BE BEYOND THE 25FT | | FRONT SETBACK. | | 5. NEW OFFICE IS ENCROACHING INTO THE | | 25FT FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|