Plan Review Stops For Permit 05071304 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-17 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-17 |
Time |
06:30 |
Sent To |
|
|
Notes |
2005-08-17 00:00:00 | APPROVED PER J. WITMER-OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-03 |
Time |
17:49 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-08-03 |
Time |
17:49 |
Sent To |
PC |
|
Notes |
2005-08-03 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05071304 | | ADD: 580 VILLAGE BLVD | | CONT: ANDERSON-MOORE | | TEL: (561)662-1819 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2) 481.219 F.S.CERTIFICATE OF | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | SHEET BEARING THE NAME OF AN ARCHITECT | | PRACTICING UNDER A FICTITIOUS NAME, A | | CORPORATION, OR A PARTNERSHIP, OFFERING | | ARCHITECTURAL SERVICES, SHALL INCLUDE | | THE CERTIFICATE OF AUTHORIZATION | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | THIS MAY BE ADDED BY HAND. | | | | 3) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 4)TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-16 |
Time |
18:13 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-08-16 |
Time |
18:13 |
Sent To |
|
|
Notes |
2005-08-16 00:00:00 | ELEC OK, | | ELECTRICAL PLANS STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-01 |
Time |
19:28 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-08-01 |
Time |
19:28 |
Sent To |
|
|
Notes |
2005-08-01 00:00:00 | ******** UNSAT ******** | | | | 1)NOTE: PLEASE SEE THE MISSING REQUIRED | | "PRINTED NAME AND LICENSE NUMBER " FOR | | THE ARCHITECT OF RECORD ON PLANS. | | FAC 61G1-16.004 | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH THE SUBMITTED | | PANEL SCHEDULE. | | PLEASE SEE "NOTES" TO POWER PLANS | | MENTIONS, "R" INDICATES RELOCATED | | OUTLETS TO EXSITING CIRCUITS? PLEASE SEE | | AN "R" COULD NOT BE LCOATED IF INDEED | | RECEPTS ARE EXSITNG. | | | | 3)NOTE: PLEASE VERIFY BY NOTE IF TENANT | | OCCUPANTS HAVE ACCESS TO OVER CURRENT | | PROTECTIVE DEVICES FOR THEIR SPACE. | | IS BLDG UNDER 24 HR MANG? | | PLEASE SEE NEC 240.24 | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELETCRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-17 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-17 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-04 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-04 |
Time |
09:32 |
Sent To |
|
|
Notes |
2005-08-04 00:00:00 | ******DENIED****** | | | | 1) PLEASE SEE OTHER REVIEW COMMENTS IN | | REGARDS TO FS AND FAC REQUIREMENTS FOR | | PLANS. | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM REMODEL. | | | | 3) CONSTRUCTION, ALTERATION AND | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | MIKE WENNERGREN, CAPTAIN | | WPBFR(561) 804-4756 | | PLAN REVIEW(561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-16 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-16 |
Time |
16:00 |
Sent To |
|
|
Notes |
2005-08-16 00:00:00 | TO "BOB"#3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-04 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-07-29 |
Time |
08:54 |
Sent To |
|
|
Notes |
2005-07-29 00:00:00 | TO "BOB" #9 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-08-02 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-08-02 |
Time |
18:44 |
Sent To |
|
|
Notes |
2005-08-02 00:00:00 | 8/2/05 NO PLANS HM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-04 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-04 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|