Plan Review Details - Permit 05071281
Plan Review Stops For Permit 05071281
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-09-20 Cont ID  
Sent By jgomez Date 2005-09-20 Time 15:42 Rev Time 0.50
Received By jgomez Date 2005-09-20 Time 15:42 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-19 Cont ID  
Sent By jgomez Date 2005-08-19 Time 09:22 Rev Time 1.00
Received By jgomez Date 2005-08-19 Time 09:22 Sent To PC
Notes
2005-08-19 00:00:00BUILDING REVIEW CHECKLIST:
 1- MINIMUM DESIGN PRESSURES SHALL BE
 10PSF AS REQUIRED BY SEC. 2002.4 FBC
 2001. SHEET #2 OF ENGINEERED DRAWINGS IS
 USING 6 PSF FOR ROOF BEAM. REVISE
 CALCULATIONS, WIND LOADS CHART AND
 GENERAL NOTE #10.
  
 2- APPLICATION CALLS FOR 18"X14" FOOTER,
 WHILE PLANS CALL FOR 12"X12".
 INFORMATION NEED TO MATCH AND SPECIFY
 FOOTING REINFORCEMENT. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 3- ENGINEERED DRAWINGS TO SPECIFY
 CONNECTION OF ALUMINUM POST TO THE
 FOOTER. SPECIFY SIZE, NUMBER AND HOW
 MUCH EMBEDMENT IS REQUIRED FOR THE
 ANCHORS. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
  
 4- ENGINEERED DRAWINGS TO SPECIFY SIZE
 OF STRUCTURAL GUTTER. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 5- SCREEN ENCLOSURE LAYOUT SHEET TO
 INCLUDE ENGINEER'S TITLE BLOCK AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
  
 6- OWNER TO PROVIDE PROOF OF OWNERSHIP.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-16 Cont ID  
Sent By adarroug Date 2005-09-16 Time 14:32 Rev Time 0.00
Received By adarroug Date 2005-09-16 Time 14:31 Sent To B
Notes
2005-09-16 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-04 Cont ID  
Sent By adarroug Date 2005-08-04 Time 10:50 Rev Time 0.00
Received By adarroug Date 2005-08-04 Time 10:50 Sent To B
Notes
2005-08-04 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 17:12 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 17:12 Sent To Z
Notes
2005-07-28 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-03 Cont ID  
Sent By mmclean Date 2005-08-03 Time 14:20 Rev Time 0.00
Received By mmclean Date 2005-08-03 Time 14:20 Sent To I
Notes
***NONE***