2005-09-29 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 05071227 |
| ADD: 1515 S FLAGLER DR |
| CONT: CAROSEL DEV |
| TEL: (561)966-0056 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| |
| |
| 1A) COMMENT FROM THE PREVIOUS REVIEW |
| NUMBER 2A) PRODUCT APPROVALS SUBMITTED |
| WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| INFORMATION PLEASE SEE THE STATE WEBSITE |
| AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| BE SUBMITTED WITH A COVER SHEET THAT |
| LISTS THE PRODUCT IDENTITY NUMBER FROM |
| THE STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| |
| |
| 1B) COMMENT FROM THE PREVIOUS REVIEW, |
| 2B)FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A)1) SLIDING DOORS - REPORT SUBMITTED |
| AL-FAROOQ CORP. ARE MISSINGTHE |
| |
| FL COVERSHEET |
| A)2) SUBMITTED AL-FAROOQ REPORTS ARE |
| FOR NON-IMPACT AND SMALL MISSLE |
| TESTING ONLY. |
| A)3) THE MIAMI-DADE REPORTS SUBMITTED; |
| 04-1014.01 THIS REPORT WAS |
| SUBMITTED WITHOUT THE TECHNICAL |
| DRAWINGS, NO PRESSURES GIVEN!!! |
| A)4) THE MIAMI-DADE REPORT SUBMITTED; |
| 04-0819.02(LARGE MISSLE) THE TYPE |
| OF GLAZING TO BE USED NOT |
| HIGHLIGHTED, NOR IS THE SILL |
| HEIGHT INDICATED WHICH LIMITS THE |
| |
| PRESSURE. |
| A)5) IF EITHER OF THE MIAMI-DADE |
| REPORTS ARE TO BE USED, THEY ARE |
| NOT LISTED ON THE FL STATE WEB |
| SITE REQUIRING LOCAL PRODUCT |
| APPROVAL. APPLICATION ATTACHED. |
| |
| |
| B)1) HORIZONTAL SLIDING WINDOWS NO |
| REPORT WAS SUBMITTED, THE |
| CONTRACTOR INDICATED THAT THIS WAS |
| |
| TO BE A CUT DOWN VERSION OF THE |
| SLIDING GLASS DOOR. |
| B)2) THE SAME ISSUES AS LISTED ABOVE |
| GLAZING TO BE HIGHLIGHTED TO WHICH |
| TYPE OF GLAZING WILL BE USED. |
| B)C) INDICATE THE TYPE OF BOTTOM TRACK |
| (HEIGHT) TO BE USED, LIMITS |
| PRESSURE. |
| |
| |
| C)1) EFIS SYSTEMS- STO SUBMITTED FL |
| COVERSHEET, MISSING THE BACK UP |
| MIAMI-DADE REPORT. |
| C)2) NOTE SINCE CONTRACTOR FAILED TO |
| SUBMIT ONE OF THE REPORTS LISTED |
| UNDER THE FL COVERSHEET THE |
| BROCHURE SUBMITTED DOES STATE THAT |
| THIS PRODUCT WAS TESTED WITH BOTH |
| GYPSUM SHEATHING & PLYWOOD |
| SHEATHING. THIS IS A MINIMUM TYPE |
| I BUILDING, NO COMBUSTIBLE |
| MATERIAL IN EXTERIOR WALL,SEE |
| TABLE 600. |
| D)1) CONTRACTOR SUBMITTED MANUFACTURES |
| CUT SHEETS ON DENSGLASS GOLD |
| EXTERIOR SHEATHING PANELS, BUT NO |
| |
| SUBMITTALS FILED UNDER THE FL. |
| PRODUCT APPROVAL SYSTEM |
| (COVERSHEET) NOR ES LEGACY REPORT |
| D)2) RICHARDSON ENGINEERING SHEET LGN |
| INDICATES THE GOVERNING DESIGN |
| FOR WIND PRESSURE FOR LIGHT GAGE |
| SYSTEM COMPONENTS AND CLADDING |
| = -123PSF. PROVIDE REPORTS WITH |
| SUCH VALUES. |
| D)3) SHEET LGN STATES NOTE L-2 THAT |
| SIGNED & SEALED CALCULATIONS MUST |
| BE SUBMITTED FOR ALL EXTERIOR |
| LIGHT GAGE FRAMING VERIFYING |
| MEMBER SIZE & GAGE, LIGHT GAGE |
| CONNECTIONS & CONNECTIONS OF |
| LIGHT GAGE TO THE BUILDING |
| STRUCTURE.NO CALCULATIONS |
| SUBMITTED. |
| D)4) NOTE, MOST EFIS REPORTS INDICATE |
| THAT THIS SYSTEM IS NOT TO BE |
| USED ON HORIZONTAL SURFACES. |
| |
| 3)COMMENT #3 FROM THE PREVIOUS REIEW; |
| FL BLD CODE 104.2.1.2 |
| ADDITIONAL INFORMATION REQUIRED, PLANS |
| DO NOT INDICATE IF NEGATIVE PRESSURES |
| TAKEN ARE END ZONE PRESSUES AND WHAT |
| TRIUTARY AREA (WINDOWS AND DOORS) WORST |
| CASE 20 SQ FT. |
| 3)A) A WIND DESIGN SHEET FROM FRANK L. |
| |
| BENNARDO WAS SUBMITTED WITH |
| POSITIVE AND NEGATIVE PRESSURES. A |
| |
| COPY OF THIS FORM IS TO BE |
| RETAINED AND POSSIBLY BE |
| FORWAARDED TO THE STATE FOR PEER |
| REVIEW BY THE ENGINEERING BOARD. |
| 3)B)PLANS, SPECIFICATIONS,REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE |
| DESIGN PROFESSIONAL AND BEING FILED |
| |
| FOR PUBLIC RECORD SHALL HAVE THE |
| SIGNATURE AND SEAL OF THE DESIGN |
| PROFESSIONAL AFFIXED TO THE |
| DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| 3)C) THIS FORM STATES IT IS TO BE USED |
| FOR DETERMINING PRELIMINARY DESIGN |
| AND IS INTENDED FOR ESTIMATING |
| PURPOSES ONLY!THE FORMAT USED IN |
| THIS SIMPLIFIED VERSION CAN ONLY BE |
| |
| USED IN A BOX TYPE DESIGN.THIS IS |
| METHOD 1 UNDER SECTION 6.4 ASCE |
| 7-98. |
| 3)D) METHOD 2 CAN NOT BE APPLIED SINCE |
| 6.5.1(1) REQUIRES THE BUILDING TO |
| BE OF A REGULAR SHAPE, DEFINITION : |
| A BUILDING OR OTHER STRUCTUE HAVING |
| NO UNUSUAL GEOMETRICAL IRREGULARITY |
| |
| IN SPATIAL FORM. |
| 6.5.1(2) THE BUILDING OR STRUCTURE |
| DOES NOT HAVE RESPONSE |
| CHARACTERISTICS MAKING IT SUBJECT TO |
| |
| ACROSS-WIND LOAADING, VORTEX |
| SHEDDING, INSTABILITY DUE TO |
| GALLOPING OR FLUTTERING OR DOES NOT |
| HAVE A SITE LOCATION FOR WHICH |
| CHANNELING EFFECTS OR BUFFETING IN |
| THE WAKE OF UPWIND OBSTRUCTIONS |
| WARRENT SPECIAL CONSIDERATION. |
| 3)E) METHOD 3 IS A WIND TUNNEL TEST!! |
| |
| 3)F) ASCE 7-98 6.5.6.5.2 BUILDINGS WITH |
| |
| A MEAN ROOF HEIGHT GREATER THAN 60' |
| SHALL BE DESIGNED USING THE EXPOSURE |
| |
| RESULTING IN THE HIGHEST WIND LOADS |
| FOR ANY WIND DIRECTION AT THE SITE. |
| 3)G) 1606.2.3 EDGE STRIPS AND END ZONES |
| PROVIDE ELEVATIONS INDICATING WHICH |
| AREAS ARE TO BE CONSIDERED AS END |
| ZONES AND INTERIOR ZONES. TAKE WORST |
| |
| CASE 20 SQ. FT. |
| |
| 4) FL. BLD CODE 1606.1.7 THE FOLLOWING |
| INFORMATION RELATED TO WIND SHALL BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| 5) COMMENT # 5 FROM THE PREVIOUS REVIEW: |
| STO DETAIL SHEETS INDICATE A SUPPORTING |
| SUBSTRATE OR SUBSHEATHING, THE PLANS DO |
| NOT IDENTIFY THIS MATERIAL, PLEASE |
| IDENTIFY. SEE TYPE I SECTION 603 OR TYPE |
| II SECTION 604 & TABLE 600. |
| CONTRACTOR SUBMITTED A STO BROCHURE BUT |
| PLANS NEED TO IDENTIFY WHAT THIS |
| MATERIAL SHALL BE. |
| |
| 6) ONCE THE STO PRODUCT APPROVALS ARE |
| SUBMITTED THE REQUIREMENTS FOR 2603.6 |
| WILL BE REVIEWED. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| |
| |
| NOTE : WORKING ON THE EXTERIOR OF THIS |
| BUILDING WILL RESULT IN PAYING 4X THE |
| FEE FOR WORKING WITHOUT A PERMIT!!!!!!! |
| |
| |
| NOTE: |
| CHAPTER 553.80(2)(B) FLORIDA STATUTES |
| STATES THAT A LOCAL GOVERNMENT SHALL |
| IMPOSE A FEE OF FOUR TIMES THE FEE FOR |
| PLAN REVIEW, IF PLANS ARE REJECTED THREE |
| OR MORE TIMES FOR REPEATED FAILURE TO |
| CORRECT A CODE VIOLATION. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |