Plan Review Details - Permit 05071114
Plan Review Stops For Permit 05071114
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-09-21 Cont ID  
Sent By jwitmer Date 2005-09-21 Time 13:29 Rev Time 0.77
Received By jwitmer Date 2005-09-21 Time 13:29 Sent To PC
Notes
2005-09-21 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05071114
 ADD: 7060 ISLA VISTA DR
 CONT: VAN KIRK & SONS
 TEL: (954)755-4402
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 POOL REVIEW
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-08-20 Cont ID  
Sent By jwitmer Date 2005-08-20 Time 10:24 Rev Time 0.33
Received By jwitmer Date 2005-08-20 Time 10:24 Sent To PC
Notes
2005-08-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05071114
 ADD: 7060 ISLA VISTA DR
 CONT: VAN KIRK & SONS
 TEL: (954)755-4402
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: REVIEWED
  
  
  
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE
 PROVIDED WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH
 424.2.17.1.14.
 424.2.17.1.5 CHILD SAFETY BARRIER
  
 2)13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-09-02 Cont ID  
Sent By dpalmer Date 2005-09-02 Time 18:06 Rev Time 0.00
Received By dpalmer Date   Time   Sent To P
Notes
2005-09-02 00:00:00PASSED BY JAKE LEAHY,
 NO ELECTRICAL CHANGES MADE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-08-05 Cont ID  
Sent By jleahy Date 2005-08-05 Time 10:39 Rev Time 0.30
Received By jleahy Date 2005-08-05 Time 10:39 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 14:00 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 14:00 Sent To E
Notes
2005-09-01 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-08-03 Cont ID  
Sent By adarroug Date 2005-08-03 Time 10:01 Rev Time 0.00
Received By adarroug Date 2005-08-03 Time 10:01 Sent To E
Notes
2005-08-03 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-26 Cont ID  
Sent By adarroug Date 2005-07-26 Time 14:08 Rev Time 0.00
Received By adarroug Date 2005-07-26 Time 14:08 Sent To Z
Notes
2005-07-26 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-09-20 Cont ID  
Sent By jleech Date 2005-09-20 Time 09:14 Rev Time 0.50
Received By jleech Date 2005-09-20 Time 09:14 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-08 Cont ID  
Sent By jleech Date 2005-08-08 Time 10:15 Rev Time 0.75
Received By jleech Date 2005-08-08 Time 10:15 Sent To B
Notes
2005-08-08 00:00:00DENIED;
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
  
 3) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 4) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING.THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL.SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER
 FUNCTION OF THE FILTRATION AND PIPING
 SYSTEMS.SEC 424.2.8.3 WHERE CHECK
 VALVES ARE INSTALLED THEY SHALL BE OF
 THE SWING OR VERTICAL CHECK PATTERNS.
 SEC 424.2.8.4 COMBINATION VALVES SHALL
 REQUIRE APPROVAL OF THE ADMINISTRATIVE
 AUTHORITY PRIOR TO THEIR INSTALLATION.
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6)424.2.9 WATER SUPPLY, LOCAL ORD. #
 2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE. (ADD TO NOTES)
 7)424.2.13.2 JOINTS AND CONNECTIONS, FBC
 PLUMBING SEC. 605.21, PURPLE PRIMER ON
 PVC PIPING. (ADD TO NOTES)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2005-08-02 Cont ID  
Sent By mmclean Date 2005-08-02 Time 10:29 Rev Time 0.00
Received By mmclean Date 2005-08-02 Time 10:29 Sent To I
Notes
***NONE***