2005-08-16 00:00:00 | DENIED |
| |
| 1)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 3) TWO COMPLETE SETS OF PLANS ARE |
| REQUIRED. |
| |
| 4) SUBMIT ENERGY CALCULATIONS AS |
| REQUIRED BY FBC CHAPTER 13. |
| |
| 5) PROVIDE AREA CALCULATIONS OF EXISTING |
| LIVING AREA (CONDITIONED SPACE) AND |
| PORCHES,GARAGES OR OTHER NON-LIVING |
| (NON-CONDITIONED) SPACE. |
| |
| 6) SPECIFY THE INSULATION FOR THE WALLS |
| AND CEILINGS. |
| |
| 7) SPECIFY THE WALL AND CEILING |
| FINISHES. |
| |
| 8) SPECIFY THE CEILING HEIGHT IN THE |
| AREA TO BE ENCLOSED. SEE FBC 1203.2.6. |
| |
| 9)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| INFORMATION RELATED TO WIND SHALL BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| 10) SPECIFY ATTIC VENTALATION AS |
| REQUIRED BY FBC 2309.7. |
| |
| 11) SPECIFY THE NEGATIVE AND POSITIVE |
| WINDLOAD PRESSURES AT THE EXTERIOR |
| OPENINGS (WINDOWS, DOORS, ETC.). |
| |
| 12) PROVIDE A TYPICAL INTERIOR WALL |
| DETAIL. |
| |
| 13) SPECIFY THE FINSH FLOOR ELEVATIONS |
| AT THE PROPOSED ENCLOSED PORCH AND THE |
| EXISTING KITCHEN ABOVE THE EXTERIOR |
| FINISH GRADE. |
| |
| 14) EVALUATE THE EXISTING SPACING, LOADS |
| AND SPANS OF THE 2X6 RAFTERS AT THE |
| PROPOSED ENCLOSED PORCH TO ENSURE THAT |
| THEY WILL BE ADEQUATE. SPECIFY THIS |
| INFORMATION ON THE PLANS. |
| |
| 15)PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. |
| SUBMIT STATE OR LOCAL PRODUCT APPROVALS |
| FOR THE EXTERIOR WINDOWS, DOORS, ROOFING |
| MATERIAL, SOLATUBE (SKYLIGHT), TRUSS |
| CONNECTORS AND STORM PANELS. |
| |
| 16) SUBMIT (2) COPIES OF A KEY PLAN AND |
| INSTALLATION SCHEDULE FOR THE STORM |
| PANELS. SPECIFY THE MOUNT TYPE, FASTENER |
| TYPE AND FASTENER SPACING ON THE |
| INSTALLATION SCHEDULE. |
| |
| 17) SUBMIT (2) COPIES OF A SITE PLAN |
| INDICATING THE DISTANCE OF THE PROPOSED |
| PORCH TO THE PROPERTY LINES IN ORDER TO |
| DETERMINE THE PERCENTAGE OF WALL OPENING |
| ALLOWED BY FBC TABLE 600. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| |
| |
| |
| |
| |