Plan Review Stops For Permit 05070837 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-01-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-01-19 |
Time |
07:15 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
2006-01-19 |
Time |
07:15 |
Sent To |
PC |
|
Notes |
2006-01-19 00:00:00 | BUILDING PROVISO: | | PROVIDE FLOOD ZONE ELEVATION | | CERTIFICATE FOR NEW CONSTRUTION WITH | | BASE FLOOD ELEVATION, CITY CODE REQUIRES | | AN ADDITIONAL 6". LOCATED IN A "A5" | | FLOOD ZONE MINIMUM ELEVATION IS 7'-6". | | ***NOTICE THE FLOOD ELEVATION | | CERTIFICATE IS CERTIFYING THE ELEVATION | | OF THE GENERATOR SLAB. THE SURVEYOR CAN | | NOT CERTIFY SOMETHING THAT IS NOT THERE. | | ALSO NOTE THAT THE MINIMUM FLOOD | | ELEVATION FOR THE CITY IS 7'-6" FOR A | | "A5" FLOOD ZONE. THIS CERTIFICATE IS | | DUE AFTER THE SLAB IS POURED AND THE | | SURVEYOR CAN TAKE THE ACTUAL FINISH | | ELEVATION OF THE SLAB. DUE BEFORE FINAL | | INSPECTION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-11-14 |
Time |
08:21 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-11-14 |
Time |
07:56 |
Sent To |
PC |
|
Notes |
2005-11-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05070837 | | ADD: 1801 S FLAGLER DR | | CONT: SULLIVAN | | TEL: (561)588-5886 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | COURT BEFORE A PERMIT CAN BE ISSUED.THE | | NOC WAS RECORDED OVER 90 DAYS BEFORE | | COMMENCEMENT OF WORK, RQUIRING A | | RE-RECORDING OF NOTICE OF COMMENCEMENT. | | SEE 713.13(2) | | | | 2)PROVISO:PROVIDE FLOOD ZONE ELEVATION | | CERTIFICATE FOR NEW CONSTRUTION WITH | | BASE FLOOD ELEVATION, CITY CODE REQUIRES | | AN ADDITIONAL 6". LOCATED IN A "A5" | | FLOOD ZONE MINIMUM ELEVATION IS 7'-6". | | ***NOTICE THE FLOOD ELEVATION | | CERTIFICATE IS CERTIFYING THE ELEVATION | | OF THE GENERATOR SLAB. THE SURVEYOR CAN | | NOT CERTIFY SOMETHING THAT IS NOT THERE. | | ALSO NOTE THAT THE MINIMUM FLOOD | | ELEVATION FOR THE CITY IS 7'-6" FOR A | | "A5" FLOOD ZONE. THIS CERTIFICATE IS | | DUE AFTER THE SLAB IS POURED AND THE | | SURVEYOR CAN TAKE THE ACTUAL FINISH | | ELEVATION OF THE SLAB. DUE BEFORE FINAL | | INSPECTION. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
09:49 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-08-28 |
Time |
09:36 |
Sent To |
PC |
|
Notes |
2005-08-28 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05070837 | | ADD: 1801 S FLAGLER DR | | CONT: SULLIVAN | | TEL: (561)588-5886 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2) PROVIDE FLOOD ZONE ELEVATION | | CERTIFICATE FOR NEW CONSTRUTION WITH | | BASE FLOOD ELEVATION, CITY CODE REQUIRES | | AN ADDITIONAL 6". LOCATED IN A "A5" | | FLOOD ZONE MINIMUM ELEVATION IS 7'-6". | | | | 3) GENERATOR SLAB & ANCHOR REQUIREMENT | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | PLUS PROVIDE PLANS WITH THE INFORMATION | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | THE DEVICE REQUIRES WITHOUT LOAD | | REDUCTION. | | SECOND, PROVIDE INFORMATION ON THE | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | WILL BEUSED. | | THE NEW SLAB AND HOLD DOWN DETAILS: | | 104.2.1* ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-10-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-07 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-10-07 |
Time |
15:17 |
Sent To |
|
|
Notes |
2005-10-07 00:00:00 | 2ND SET OF SUBMITTIALS STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
19:26 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-09-29 |
Time |
19:07 |
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | IN "F" STATUS ONLY AWAITING 2ND SET OF | | SUBMITTALS. | | CALLED CONTRACTOR FOR 2ND SET, WILL | | BRING IN. | | SEE DV PALMER. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-03 |
Time |
18:48 |
Rev Time |
2.25 |
Received By |
dpalmer |
Date |
2005-08-03 |
Time |
18:47 |
Sent To |
|
|
Notes |
2005-08-03 00:00:00 | ****** UNSAT ******* | | | | 1)NOTE: PLEASE SEE FIRE PUMP INFORMATION | | IS CURRENTLY BEING REVIEWED UNDER | | GENERATOR PERMIT, HOWEVER FIRE PUMP WILL | | BE REQUIRED TO BE PERMITTED SEPARATELY. | | PLEASE SEE THIS MAY BE SUBMITTED ALONG | | WITH GENERATOR PERMIT SO IT MAY BE | | REVIEWED AND PERMITTED AT THE SAME TIME. | | PLANS, SPECS WILL BE REQUIRED FOR EACH | | AS EACH WILL BE FILED UNDER SEPRATE | | FILES. | | | | 2)NOTE: PLEASE SUBMIT ALL MANUFACTURE | | SPECS/CUT SHEETS FOR GENERATOR, ATS, | | FIRE PUMP, FIRE PUMP CONTROLLER. | | PLEASE SEE OTHER COMMENTS FOR FPC, AS | | SOME INFORMATION CAN NOT VERIFIED AT | | THIS TIME. | | 215.5 | | | | 3)NOTE: PLEASE SEE CONDUCTORS FROM FPL, | | GENERATOR TO FIRE PUMP, FIRE PUMP CONT, | | SHALL BE BASED ON 125%. | | PLEASE SEE 695.6(C)(2) ETC. | | PLEASE SEE PLANS INDICATE EXSITING | | "NAMEPLATE @ 100HP, 250 FLA'S. THIS IS | | ONLY A NOTE FOR VERIFICATION. NO | | CORRECTION NEEDED. | | | | 4)NOTE: PLEASE SEE SPECS/CUT SHEETS FOR | | FPC WERE SUBMITTED, HOWEVER PLEASE NOTE | | THE MANUAL MEANS OF DISCONNECT LOCATED | | ON OUTSIDE OF EQUIPMENT, RATED FOR THE | | LAOD SERVED SHALL BE PART OF THE FPC. | | PLEASE SEE 230.76,230.79,NFPA-20 CHAPTER | | 7-4. | | 5)NOTE:PLEASESEE THE LOCATION OF FIRE | | PUMP CONTROLLER SHALL BE ARRANGED TO | | PREVENT ANY DAMAGE TO FPC EQUIPMENT IN | | THE EVENT OF FIRE/EXPLOSION ETC. | | PLEASE KNOW,IT IS KNOWN THIS IS AN | | EXSITING ROOM AND THERE ARE SOME | | EXISTING CONDITIONS WHICH CAN NOT BE | | AVOIDED. HOWEVER,A STEEL REINFORCED | | CONCRETE WALL WILL BE REQUIRED TO HELP | | IN SHIELDING ANY SUCH FIRE /EXPLOSION | | FROM MAIN SERVICE EQUIPMENT. | | PLEASE SEE 695.3, NFPA-20 6-2.1.ETC | | | | 6)NOTE: PLEASE SEE THE LOCATION OF FIRE | | PUMP CONTROLLER SHALL BE SUCH THE | | LEAKING OF ANY WATERFROM FIRE PUMP , | | FIRE SPRINKLERS ETC WILL NOT AFFECT THE | | FPC, PLEASE SEE NFPA-20 7-2,7-3.3.1, FOR | | ENCLOSURE TYPE ETC. | | PLEASE SEE NOTE ON PLANS MENTIONS FOR | | FEEDERS FROM GEN TO ENTER BLDG AS LOW AS | | POSSIBLE INTO REAR OF FIRE PUMP | | CONTROLLER, HOWEVER PLEASE SEE | | 7-2.2,695.12, WHICH REQUIRES FPC TO BE | | MOUNTED A MIN OF 12" ABOVE FLR. | | | | 7)NOTE: PLEASE PROVIDE NOTE FOR SIGNAGE | | FOR ALL ELECTRICAL EQUIPMENT. | | 695.4B3,4 ETC. | | | | 8)NOTE: PLEASE SEE PROTECTIVE BOLLARDS | | WILL BE REQUIRED OUTSIDE TO PROTECT GEN | | ENCLOSURE FROM PARKING LOT AREA. | | PLEASE SEE ANY ZONING COMMENTS. | | | | 9)NOTE: PLEASE SEE PLANS MENTIONS PIPING | | IN ROOM SHALL BE EMT, PLEASE SEE | | 695.6(2)(E). | | | | 10)NOTE: PLEASE SEE 701.11(B)(2)(3) FOR | | SOURCES OF FUEL. | | PLEASE SEE IT IS KNOWNTO OUR OFFICE | | THE LOCAL UTILITY COMAPNY SUPPLYING | | NATURAL GAS SEEMS TO BE AT OVER 500% | | CAPACITY. PLEASE SEE AN ALTERANTE FUEL | | SOURCE WILL BE REQUIRED FOR MIN REQUIRED | | RUN TIME. | | | | 11)NOTE: PLEASE SEE SITE PLAN / SURVEY | | WILL BE REQUIRED TO INDICATE THE BASE | | FLOOD ELEVATION (BFE). GEN SLAB SHALL BE | | A MIN OF 6" ABOVE BFE. PLEASE SEE BLDG | | REVIEW COMMENTS. | | PLEASE SEE BLDG REVIEW COMMENTS FOR | | BOLT/TIE DOWN CONNECTIONS REQUIRED. | | | | 12)NOTE: PLEASE SEE FBC LOCAL | | ADMINISTRATIVE SECTION 104.6.5, PERMIT | | VALUATION IS BASED ON ALL LABOR AND | | MATERIALS, EVEN IF EQUIPMENT IS OWNER | | SUPPLIED. PLEASE ADJUST. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-09-30 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-09-30 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-23 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-23 |
Time |
12:47 |
Sent To |
|
|
Notes |
2005-08-23 00:00:00 | ******DENIED****** | | | | 1) PLEASE NOTE THAT MANUFACTURER SPEC | | SHEETS ARE REQUIRED FOR GENERATOR AND | | ASSOCIATED EQUIPMENT. | | | | 2) PLEASE PROVIDE A MEANS OF PROTECTING | | THE GENERATOR AGAINST MECHANICAL DAMAGE. | | | | 3) GENERATOR TO COMPLY WITH NFPA 110 AND | | OTHER APPLICABLE CODES. | | | | 4) PLEASE SEE ELECTRICAL REVIEW COMMENT | | REGARDING SEPARATE SHOP DRAWING AND | | PERMIT WITH SHOP CALCS FOR FIRE PUMP. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-05-05 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-05-05 |
Time |
07:39 |
Sent To |
|
|
Notes |
2006-05-05 00:00:00 | REVISION |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-04-29 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-04-29 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-04-29 |
Time |
09:20 |
Sent To |
PC |
|
Notes |
2006-04-29 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC2001 FUEL GAS CODEPLAN REVIEW | | FBC 2001 PLUMBING CODEPLAN REVIEW | | FBC 2001 FL ACESSIBILITY CODE PLAN | | REVIEW | | | | REVISIONUNSAT | | | | REVISION NOT DRAWN AS BUILT | | | | END OF COMMENTS QUSTIONS 561-805-6692 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-03 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-03 |
Time |
11:12 |
Sent To |
G |
|
Notes |
2006-05-03 00:00:00 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-12-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-19 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-19 |
Time |
14:42 |
Sent To |
|
|
Notes |
2006-01-18 00:00:00 | GIVEN TO MICHELLE MCLEAN FOR REVIEW/ | | DISCUSSION WITH ANGELLA JONES-VANN. | | | | | 2005-12-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-20 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-20 |
Time |
09:14 |
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | TO "COMM" BD#6 | 2005-09-20 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-29 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-07-21 |
Time |
16:21 |
Sent To |
|
|
Notes |
2005-07-22 00:00:00 | TO "COMM" BD#61 | 2005-07-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-10-18 |
Time |
14:02 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2005-10-18 |
Time |
14:02 |
Sent To |
Z |
|
Notes |
2005-10-18 00:00:00 | INSTALLED BOLLARDS AROUND THE NATURAL | | GAS GENERATOR. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-08-09 |
Time |
13:38 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-08-09 |
Time |
13:20 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | PLEASE PROVIDE MANUFACTURER'S SUBMITTAL | | DATA FOR THE GENERATOR.ADDITIONAL | | PERMIT REQUIRED FOR NEW GAS LINE | | INSTALLATION. | | | | PER 2001 FBC(M)303.4, EQUIPMENT SHALL | | NOT BE LOCATED WHERE DAMAGE MAY OCCUR | | UNLESS PROTECTED BY APPROVED BARRIERS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-10-17 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-10-15 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-10-15 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-08-24 |
Time |
06:48 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2005-08-24 |
Time |
06:26 |
Sent To |
|
|
Notes |
2005-08-24 00:00:00 | DENIED | | REFERENCE: FBC-2001 FUEL GAS | | | | A. THE FOLLOWING INFORMATION IS REQUIRED | | FOR REQUIRED GAS PERMIT: | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. | | 2. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | 3. SUBMIT CALCULATIONS FOR COMBUSTION | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | GAS CODE SECTION 304. | | 4. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | 5. SUBMIT A DETAIL SHOWING THE TYPE, | | LOCATION, SIZE AND TERMINATION OF THE | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | SECS. 502 THRU 506. | | 6. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2001 FUEL GAS CODE SEC 402.2. | | 7. INDICATE THE BTU LOAD OF EXISTING | | GENERATOR. IF NEW GENERTATOR IS A | | SUBSTANTIAL ADDITION TO SYSTEM, TOTAL | | BTU OF SYSTEM MAY BE REQUIRED TO CHECK | | PIPE SIZING OUT OF THE METER. (BTU LOAD | | OF EACH APPLIANCE AND THE TOTAL BTU LOAD | | ON THE SYSTEM. REFER TO THE FBC-2001 | | FUEL GAS CODE SECS. 401.8 THRU 402.5.2 | | AND TABLES 402(1) THRU 402(34)). | | 8. PLANS INDICATE THAT THE UNDERGROUND | | PIPING SHALL HAVE A MINIMUM OF 12" | | COVER. SECTION 404.9 REQUIRES MINIMUM | | 18" COVER, BUT MAY BE REDUCED TO 12" | | WHERE EXTERNAL DAMAGE IS NOT LIKELY TO | | RESULT. PLEASE INDICATE HOW THIS | | EXCEPTION WILL BE APPROVED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2006-01-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-18 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-18 |
Time |
11:21 |
Sent To |
B |
|
Notes |
2006-01-18 00:00:00 | OK, HAVE MORE PARKING SPACE THAN NEEDED. | | | | GIVEN TO JIM WITMER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-10-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-10-21 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-10-21 |
Time |
08:55 |
Sent To |
I |
|
Notes |
2005-11-02 00:00:00 | DENIED, | | 1. GENERATOR CANNOT BE LOCATED IN A | | REQUIRED PARKING LOT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-29 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-29 |
Time |
15:49 |
Sent To |
|
|
Notes |
2005-08-29 00:00:00 | DENIED, | | 1. NEED TO PROVIDE TWO COPY OF | | SURVEY/SITEPLANS SHOWING THE LOCATION OF | | THE GENERATOR AND SETBACKS. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|