Plan Review Details - Permit 05070631
Plan Review Stops For Permit 05070631
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-08-06 Cont ID  
Sent By jwitmer Date 2005-08-06 Time 07:21 Rev Time 0.44
Received By jwitmer Date 2005-08-06 Time 07:21 Sent To PC
Notes
2005-08-06 00:00:00BUILDING PLAN REVIEW
 PERMIT:05070631
 ADD: 7210 WINDING BAY LN
 CONT: NATURAL BEAUTY WOOD PRO., INC
  
 TEL: (561)732-0224
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: REVIEWED
  
 BUILDING PROVISO:
  
 IF FENCE IS PART OF A POOL BOUNDRY MUST
 COMPLY WITH:
 424.2.17.1.1 THE TOP OF THE BARRIER
 SHALL BE AT LEAST 48 INCHES ABOVE GRADE
 MEASURED ON THE SIDE OF THE BARRIER
 WHICH FACES AWAY FROM THE SWIMMING POOL.
 THE MAXIMUM VERTICAL CLEARANCE BETWEEN
 GRADE AND THE BOTTOM OF THE BARRIER
 SHALL BE 2 INCHES MEASURED ON THE SIDE
 OF THE BARRIER WHICH FACES AWAY FROM THE
 SWIMMING POOL.WHERE THE TOP OF THE
 POOL STRUCTURE IS ABOVE GRADE THE
 BARRIER MAY BE AT GROUND LEVEL OR
 MOUNTED ON TOP OF THE POOL STRUCTURE.
 WHERE THE BARRIER IS MOUNTED ON TOP OF
 THE POOL STRUCTURE, THE MAXIMUM VERTICAL
 CLEARANCE BETWEEN THE TOP OF THE POOL
 STRUCTURE AND THE BOTTOM OF THE BARRIER
 SHALL BE 4 INCHES.
  
 424.2.17.1.2 THE BARRIER MAY NOT HAVE
 ANY GAPS, OPENINGS, INDENTATIONS,
 PROTRUSIONS, OR STRUCTURAL COMPONENTS
 THAT COULD ALLOW A YOUNG CHILD TO CRAWL
 UNDER, SQUEEZE THROUGH, OR CLIMB OVER
 THE BARRIER AS HEREIN DESCRIBED BELOW.
 ONE END OF A REMOVABLE CHILD BARRIER
 SHALL NOT BE REMOVABLE WITHOUT THE AID
 OF TOOLS.OPENINGS IN ANY BARRIER SHALL
 NOT ALLOW PASSAGE OF A 4-INCH DIAMETER
 SPHERE.
  
 424.2.17.1.6 MAXIMUM MESH SIZE FOR CHAIN
 LINK FENCES SHALL BE A 2-1/4 INCH SQUARE
 UNLESS THE FENCE IS PROVIDED WITH SLATS
 FASTENED AT THE TOP OR BOTTOM WHICH
 REDUCE THE OPENINGS TO NO MORE THAN
 1-3/4 INCHES.
  
 424.2.17.1.7 WHERE THE BARRIER IS
 COMPOSED OF DIAGONAL MEMBERS, THE
 MAXIMUM OPENING FORMED BY THE DIAGONAL
 MEMBERS SHALL BE NO MORE THAN 1-3/4
 INCHES.
  
 424.2.17.1.8 ACCESS GATES, WHEN
 PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF
 ?424.2.17.1.1 THROUGH 424.2.17.1.7 AND
 SHALL BE EQUIPPED WITH A SELF-LATCHING
 LOCKING DEVICE LOCATED ON THE POOL SIDE
 OF THE GATE.WHERE THE DEVICE
 RELEASE IS LOCATED NO LESS THAN 54
 INCHES FROM THE BOTTOM OF THE GATE, THE
 DEVICE RELEASE MECHANISM MAY BE LOCATED
 ON EITHER SIDE OF THE GATE AND SO PLACED
 THAT IT CANNOT BE REACHED BY A YOUNG
 CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE.GATES
 THAT PROVIDE ACCESS TO THE SWIMMING POOL
 MUST OPEN OUTWARD AWAY FROM THE POOL.
 THE GATES AND BARRIER SHALL HAVE NO
 OPENING GREATER THAN 1/2 INCH WITHIN 18
 INCHES OF THE RELEASE MECHANISM.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 10:24 Rev Time 0.00
Received By adarroug Date 2005-07-27 Time 10:24 Sent To B
Notes
2005-07-27 00:00:00TO "MISC" BOX #2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 08:44 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 08:43 Sent To Z
Notes
2005-07-18 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-26 Cont ID  
Sent By mmclean Date 2005-07-26 Time 10:22 Rev Time 0.00
Received By mmclean Date 2005-07-26 Time 10:22 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy