Plan Review Details - Permit 05070582
Plan Review Stops For Permit 05070582
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-09-06 Cont ID  
Sent By jwitmer Date 2005-09-06 Time 13:35 Rev Time 0.33
Received By jwitmer Date 2005-09-06 Time 13:35 Sent To PC
Notes
2005-09-06 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05070582
 ADD: 10687 HOLLOW BAY TERRACE
 CONT: VAN KIRK & SONS
 TEL: (954)755-4402
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
  
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE
 PROVIDED WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH
 424.2.17.1.14.
 424.2.17.1.5 CHILD SAFETY BARRIER
  
 2)13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-08-13 Cont ID  
Sent By jwitmer Date 2005-08-13 Time 14:56 Rev Time 0.00
Received By jleech Date 2005-08-30 Time 13:39 Sent To PC
Notes
2005-08-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05070582
 ADD: 10687 HOLLOW BAY TERRACE
 CONT:VAN KIRK & SONS
 TEL: (954)755-4402
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST POOL REVIEW
 ACTION:DENIED
 1 ) FL S S 472.025 / 61G17-6.002(8)(E)
  
 61G17-6.002(8)(E) ALL SURVEY MAPS AND
 REPORTS OR COPIES THEREOF ARE NOT VALID
 WITHOUT THE ORIGINAL SIGNATURE, AND THE
 ORIGINAL RAISED SEAL OF A FLORIDA FOR
 LICENSED SURVEYORS AND MAPPERS.
  
 61G17-6.002(8)(C) ALL SURVEY MAPS AND
 REPORTS MUST BEAR THE NAME, "CERTIFICATE
 OF AUTHORIZATION NUMBER", AND THE STREET
 MAILING ADDRESS OF THE BUSINESS ENITITY
 ISSUING THE MAP OR REPORT, ALONG WITH
 NAME AND LICENSE NUMBER OF THE SURVEYOR
 AND MAPPER IN RESPONSIBLE CHARGE.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-31 Cont ID  
Sent By jleahy Date 2005-08-31 Time 22:03 Rev Time 0.30
Received By jleahy Date 2005-08-31 Time 22:03 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-07-29 Cont ID  
Sent By jleahy Date 2005-07-29 Time 07:29 Rev Time 0.30
Received By jleahy Date 2005-07-29 Time 07:29 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-13 Cont ID  
Sent By adarroug Date 2006-01-13 Time 13:56 Rev Time 0.00
Received By adarroug Date 2006-01-13 Time 13:56 Sent To P
Notes
2006-01-13 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-19 Cont ID  
Sent By adarroug Date 2005-08-19 Time 16:43 Rev Time 0.00
Received By adarroug Date 2005-08-19 Time 16:43 Sent To E
Notes
2005-08-19 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-26 Cont ID  
Sent By adarroug Date 2005-07-26 Time 11:42 Rev Time 0.00
Received By adarroug Date 2005-07-26 Time 11:42 Sent To E
Notes
2005-07-26 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-15 Cont ID  
Sent By adarroug Date 2005-07-15 Time 10:16 Rev Time 0.00
Received By adarroug Date 2005-07-15 Time 10:16 Sent To Z
Notes
2005-07-15 00:00:00TO "Z"BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-01-25 Cont ID  
Sent By mperson Date 2006-01-25 Time 08:42 Rev Time 0.33
Received By mperson Date 2006-01-25 Time 08:42 Sent To PC
Notes
2006-01-25 00:00:00REVISION: DELETE 400,000 BTU NAT. GAS
 POOL HEATER.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-30 Cont ID  
Sent By jleech Date 2005-08-30 Time 13:40 Rev Time 0.33
Received By jleech Date 2005-08-30 Time 13:40 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-04 Cont ID  
Sent By jleech Date 2005-08-04 Time 08:45 Rev Time 0.75
Received By jleech Date 2005-08-04 Time 08:45 Sent To B
Notes
2005-08-04 00:00:001) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 3) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 4) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING.THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL.SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER
 FUNCTION OF THE FILTRATION AND PIPING
 SYSTEMS.SEC 424.2.8.3 WHERE CHECK
 VALVES ARE INSTALLED THEY SHALL BE OF
 THE SWING OR VERTICAL CHECK PATTERNS.
 SEC 424.2.8.4 COMBINATION VALVES SHALL
 REQUIRE APPROVAL OF THE ADMINISTRATIVE
 AUTHORITY PRIOR TO THEIR INSTALLATION.
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6)FBC-2001 424.2.9 WATER SUPPLY LOCAL
 ORD. #2853-95 BACKFLOW REQUIRED ON WATER
 SERVICE. (ADD TO NOTES)
 7)FBC-2001 424.2.13.2 JOINTS AND
 CONECTIONS, FBC PLBG SEC. 605.21, PERPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 8)FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-25 Cont ID  
Sent By mmclean Date 2005-07-25 Time 12:42 Rev Time 0.00
Received By mmclean Date 2005-07-25 Time 12:42 Sent To I
Notes
***NONE***