Plan Review Details - Permit 05070261
Plan Review Stops For Permit 05070261
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-09-01 Cont ID  
Sent By mjacobs Date 2005-09-01 Time 11:37 Rev Time 1.00
Received By mjacobs Date 2005-09-01 Time 10:39 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-08-12 Cont ID  
Sent By mjacobs Date 2005-08-12 Time 08:08 Rev Time 1.75
Received By mjacobs Date 2005-08-12 Time 06:55 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-31 Cont ID  
Sent By jleahy Date 2005-08-31 Time 21:53 Rev Time 0.00
Received By jleahy Date 2005-08-31 Time 21:51 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-07-20 Cont ID  
Sent By btrobaug Date 2005-07-20 Time 13:29 Rev Time 0.33
Received By btrobaug Date 2005-07-20 Time 13:25 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-19 Cont ID  
Sent By adarroug Date 2005-08-19 Time 14:32 Rev Time 0.00
Received By adarroug Date 2005-08-19 Time 14:32 Sent To P
Notes
2005-08-19 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-19 Cont ID  
Sent By adarroug Date 2005-07-19 Time 15:04 Rev Time 0.00
Received By adarroug Date 2005-07-19 Time 15:04 Sent To E
Notes
2005-07-19 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 16:06 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 16:06 Sent To Z
Notes
2005-07-08 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-31 Cont ID  
Sent By jleech Date 2005-08-31 Time 15:21 Rev Time 0.33
Received By jleech Date 2005-08-31 Time 15:21 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-08-01 Cont ID  
Sent By jleech Date 2005-08-01 Time 10:14 Rev Time 1.00
Received By jleech Date 2005-08-01 Time 10:14 Sent To B
Notes
2005-08-01 00:00:00DENIED;
 1.POOL COMPLIES WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS (ADD TO NOTES)
 2.SEC. 424.2.6/1 ENGINEERING DESIGN,
 CONSTRUCTION AND WORKMANSHIP PER.
 ANSI/NSPI-5 (ADD TO NOTES)
 3.SEC.424.2.6.6.2 SHOW COMPLIANCE WITH
 ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF. INFORMATION FOR
 VAC.LOCK. (GIVE DETAIL , SUBMITTLE OR
 ADD TO NOTES)
 4.SEC.424.2.8/1 -4 VALVES SHALL BE
 APPROVED BY FBC-2001.THEY WILL BE
 READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL. FULL WAY VALVES SHALL BE
 INSTALLED. WHERE CHECK VALVES ARE
 INSTALLED THEY SHALL OF THE SWING OR
 VERTICAL CHECK PATTERNS.
 5.SEC.424.2.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE. (ADD TO NOTES)
 6.SEC.424.2.12.1PRESSURE TESTS. PER.
 MANUFACTURE RECOMMENDATIONS, NO AIR TEST
 SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 7.SEC.424.2.13.2 JOINTS AND CONNECTIONS.
 FBC PLUMBING SEC. 605.21, PURPLE PRIMER
 REQUIRED ON PVC PIPE. (ADD TO NOTES)
 8.SEC.424.2.15 GAS PIPING SHALL COMPLY
 WITH FBC 2001 FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-18 Cont ID  
Sent By mmclean Date 2005-07-18 Time 17:14 Rev Time 0.00
Received By mmclean Date 2005-07-18 Time 17:14 Sent To I
Notes
***NONE***