Plan Review Details - Permit 05061832
Plan Review Stops For Permit 05061832 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-14 |
Time |
15:43 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2005-09-14 |
Time |
15:43 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-02 |
Time |
13:48 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-09-02 |
Time |
13:48 |
Sent To |
PC |
|
Notes |
2005-09-02 00:00:00 | BUILDING REVIEW SECOND CHECKLIST: | | 1- PROVIDE COMPLETE INFORMATION ON SHEET | | 17 AS REQUIRED BY GUIDE TO USE CHARTS | | AND GRAPHS ON SHEET 2 OF THE ROLL UP | | SHUTTER DRAWINGS. | | | | ***NOTE: SUBMITTED ENGINEER'S LETTER | | FROM WARREN W. SCHAEFER, P.E. CAN'T | | ALTER THE REQUIREMENTS OF THE DADE | | COUNTY NOA. | | FIRST OF ALL, ANY ALTERATION TO THE NOA | | WILL VOID THE NOA. SEE TERMINATION NOTE | | ON FRONT PAGE OF THE NOA. | | SECOND, ENGINEER WHO SUBMITTED THIS | | LETTER IS NOT THE ENGINEER RESPONSIBLE | | FOR THE APPROVED PRODUCT. | | FINALLY, IN ORDER TO REVISE PRODUCT | | APPROVAL MANUFACTURER NEEDS TO GET AN | | APPROVED REVISED PRODUCT APPROVAL THAT | | EXCLUDES THE NON HIGH VELOCITY AREAS | | FROM CERTAIN REQUIREMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-07-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-21 |
Time |
14:23 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-07-21 |
Time |
14:23 |
Sent To |
PC |
|
Notes |
2005-07-21 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | 1- PROVIDE DESIGN PRESSURES ACCORDING TO | | THE BUILDING GEOMETRICAL SHAPE, HEIGHT, | | OPEN OR ENCLOSED BUILDING, EXPOSURE | | CATEGORY, TRIBUTARY AREA AND ZONE | | LOCATION AS REQUIRED BY ASCE 7-98. | | PROVIDE ENGINEERED CALCULATIONS. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 2- ENGINEERED WIND LOAD TABLE NEEDS TO | | BE SIGNED AND SEALED BY THE ENGINEER WHO | | PREPARED IT AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES. | | TABLE IS GENERIC. ENGINEER TO PROVIDE | | CALCULATIONS FOR ACTUAL BUILDING | | CONSIDERING THE FACTS LISTED ON ITEM #1 | | ABOVE. SEC. 104.2.1.2 CITY AMENDMENTS TO | | FBC 2001. | | | | 3- PROVIDE COMPLETE INFORMATION ON SHEET | | 17 AS REQUIRED BY GUIDE TO USE CHARTS | | AND GRAPHS ON SHEET 2 OF THE ROLL UP | | SHUTTER DRAWINGS. | | | | 4- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-13 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-13 |
Time |
14:10 |
Sent To |
B |
|
Notes |
2005-09-13 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-01 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-01 |
Time |
11:11 |
Sent To |
B |
|
Notes |
2005-09-01 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-30 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-30 |
Time |
10:25 |
Sent To |
B |
|
Notes |
2005-06-30 00:00:00 | TO "MISC" BOX |
|
|
|