Plan Review Details - Permit 05061832
Plan Review Stops For Permit 05061832
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-14 Cont ID  
Sent By jgomez Date 2005-09-14 Time 15:43 Rev Time 0.33
Received By jgomez Date 2005-09-14 Time 15:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-09-02 Cont ID  
Sent By jgomez Date 2005-09-02 Time 13:48 Rev Time 0.50
Received By jgomez Date 2005-09-02 Time 13:48 Sent To PC
Notes
2005-09-02 00:00:00BUILDING REVIEW SECOND CHECKLIST:
 1- PROVIDE COMPLETE INFORMATION ON SHEET
 17 AS REQUIRED BY GUIDE TO USE CHARTS
 AND GRAPHS ON SHEET 2 OF THE ROLL UP
 SHUTTER DRAWINGS.
  
 ***NOTE: SUBMITTED ENGINEER'S LETTER
 FROM WARREN W. SCHAEFER, P.E. CAN'T
 ALTER THE REQUIREMENTS OF THE DADE
 COUNTY NOA.
 FIRST OF ALL, ANY ALTERATION TO THE NOA
 WILL VOID THE NOA. SEE TERMINATION NOTE
 ON FRONT PAGE OF THE NOA.
 SECOND, ENGINEER WHO SUBMITTED THIS
 LETTER IS NOT THE ENGINEER RESPONSIBLE
 FOR THE APPROVED PRODUCT.
 FINALLY, IN ORDER TO REVISE PRODUCT
 APPROVAL MANUFACTURER NEEDS TO GET AN
 APPROVED REVISED PRODUCT APPROVAL THAT
 EXCLUDES THE NON HIGH VELOCITY AREAS
 FROM CERTAIN REQUIREMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-21 Cont ID  
Sent By jgomez Date 2005-07-21 Time 14:23 Rev Time 0.50
Received By jgomez Date 2005-07-21 Time 14:23 Sent To PC
Notes
2005-07-21 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- PROVIDE DESIGN PRESSURES ACCORDING TO
 THE BUILDING GEOMETRICAL SHAPE, HEIGHT,
 OPEN OR ENCLOSED BUILDING, EXPOSURE
 CATEGORY, TRIBUTARY AREA AND ZONE
 LOCATION AS REQUIRED BY ASCE 7-98.
 PROVIDE ENGINEERED CALCULATIONS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 2- ENGINEERED WIND LOAD TABLE NEEDS TO
 BE SIGNED AND SEALED BY THE ENGINEER WHO
 PREPARED IT AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES.
 TABLE IS GENERIC. ENGINEER TO PROVIDE
 CALCULATIONS FOR ACTUAL BUILDING
 CONSIDERING THE FACTS LISTED ON ITEM #1
 ABOVE. SEC. 104.2.1.2 CITY AMENDMENTS TO
 FBC 2001.
  
 3- PROVIDE COMPLETE INFORMATION ON SHEET
 17 AS REQUIRED BY GUIDE TO USE CHARTS
 AND GRAPHS ON SHEET 2 OF THE ROLL UP
 SHUTTER DRAWINGS.
  
 4- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-13 Cont ID  
Sent By adarroug Date 2005-09-13 Time 14:10 Rev Time 0.00
Received By adarroug Date 2005-09-13 Time 14:10 Sent To B
Notes
2005-09-13 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 11:11 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 11:11 Sent To B
Notes
2005-09-01 00:00:00TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-30 Cont ID  
Sent By adarroug Date 2005-06-30 Time 10:25 Rev Time 0.00
Received By adarroug Date 2005-06-30 Time 10:25 Sent To B
Notes
2005-06-30 00:00:00TO "MISC" BOX