Plan Review Details - Permit 05061718
Plan Review Stops For Permit 05061718
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-01-03 Cont ID  
Sent By jgomez Date 2006-01-03 Time 17:19 Rev Time 1.00
Received By jgomez Date 2006-01-03 Time 17:19 Sent To PC
Notes
2006-01-03 00:00:00PROVISO ITEMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-07-25 Cont ID  
Sent By jgomez Date 2005-07-25 Time 16:48 Rev Time 2.00
Received By jgomez Date 2005-07-25 Time 16:48 Sent To PC
Notes
2005-07-25 00:00:00BUILDING REVIEW PROVISO:
 1- SHUTTERS UNDR A SEPARATE PERMIT.
 2- REAR ELEVATION NEEDS TO BE FIX.
 SLIDING GLASS DOOR IS SHOWN INCORRECTLY.
 3- CLARIFY WINDOW/DOOR SCHEDULE. DON'T
 MIX TOGETHER WINDOW/DOOR SYMBOLS.
 4- REVISE DETAIL 5/D1: CONNECTOR HTS20
 CAN'T SUPPORT GIRDER TRUSS.
 5- UPDATE HUS26 NUMBER OF NAILS. SEE
 2005 CATALOGUE PAGE 58.
 6- REVISE CONNECTOR SPECIFIED AT ENTRY
 PORCH TO MATCH DETAIL 6/D1.
 7- RE-SUBMIT PRODUCT APPROVAL FOR:
 A)ROOF TILE, B)SINGLE HUNG WINDOWS,
 C)FIXED WINDOWS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-10 Cont ID  
Sent By dpalmer Date 2006-02-10 Time 07:49 Rev Time 0.00
Received By dpalmer Date 2006-02-10 Time 07:49 Sent To PC
Notes
2006-02-10 00:00:00REDLINED:
  
  
 250.52A5 GRND ROD SHALL BE A MIN OF 8'
  
 VIF OCP FOR CU, SHOWS 9.8KW ON 40A OCP
  
 OCP FOR AHU# 2 SHALL BE SIZED PER
 424.3B, MIN OCP TO BE 125%.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-07-13 Cont ID  
Sent By dpalmer Date 2005-07-13 Time 13:10 Rev Time 0.30
Received By dpalmer Date 2005-07-13 Time 13:10 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-01 Cont ID  
Sent By adarroug Date 2006-02-01 Time 18:06 Rev Time 0.00
Received By adarroug Date 2006-02-01 Time 18:05 Sent To E
Notes
2006-02-01 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-29 Cont ID  
Sent By adarroug Date 2005-12-29 Time 11:04 Rev Time 0.00
Received By adarroug Date 2005-12-29 Time 11:04 Sent To B
Notes
2005-12-29 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-12 Cont ID  
Sent By adarroug Date 2005-07-12 Time 15:22 Rev Time 0.00
Received By adarroug Date 2005-07-12 Time 15:22 Sent To E
Notes
2005-07-12 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-01 Cont ID  
Sent By adarroug Date 2005-07-01 Time 15:07 Rev Time 0.00
Received By adarroug Date 2005-07-01 Time 15:07 Sent To Z
Notes
2005-07-01 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-19 Cont ID  
Sent By hmoser Date 2005-07-19 Time 17:52 Rev Time 0.00
Received By hmoser Date 2005-07-19 Time 17:24 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-07-23 Cont ID  
Sent By jleech Date 2005-07-23 Time 06:45 Rev Time 0.33
Received By jleech Date 2005-07-23 Time 06:45 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-12 Cont ID  
Sent By mmclean Date 2005-07-12 Time 07:35 Rev Time 0.00
Received By mmclean Date 2005-07-12 Time 07:35 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved