Plan Review Stops For Permit 05061533 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-04-05 |
Time |
10:19 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-04-05 |
Time |
07:49 |
Sent To |
|
|
Notes |
2006-04-05 00:00:00 | ENERGY CALCS AND ATRIUM DOOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-03-14 |
Time |
17:40 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-03-14 |
Time |
17:40 |
Sent To |
|
|
Notes |
2006-03-14 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | 1- ENERGY CALCULATIONS SUBMITTED SHOW | | THAT CREDIT IS TAKEN FOR CEILING FANS. | | REVISE ELECTRICAL PLANS AS REQUIRED TO | | SHOW CEILING FANS IN ALL ROOMS. SEE | | TABLE 6-6 OF CHAPTER 13 FBC 2001 FOR | | MINIMUM NUMBER AND SIZE OF CEILIG FANS | | REQUIRED FOR EACH ROOM. SHOW SIZE AND | | NUMBER REQUIRED IN ELECTRICAL PLAN. | | | | 2- ARCHITECT SIGNED AND SEALED PRODUCT | | APPROVAL FOR ATRIUM DOOR. ARCHITECT IS | | NOT ALLOWED TO SIGN AND SEAL DOCUMENTS | | THAT HE DIDN'T DESIGNED OR PRODUCED | | UNDER HIS SUPERVISION. ARCHITECT TO SEE | | FLORIDA ADMINISTRATIVE CODE. RE-SUBMIT | | AS REQUIRED. | | | | NOTE: | | PLANS FOR THIS HOUSE WERE APPROVED UNDER | | FBC 2001, NOT FBC 2004. CITY AMENDMENTS | | TO FBC 2004 IS THE CODE THAT REQUIRES | | DESIGNER OF RECORD TO REVIEW AND APPROVE | | IN WRITTING (NOT SIGN AND SEAL) ALL | | PRODUCT APPROVALS. | | | | 3- CONTRACTOR TO APPLY FOR STORM | | SHUTTERS PERMIT AS AGREED ON PROVISO AS | | SOON AS POSSIBLE TO AVOID CONFLICT OR | | DELAYS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-21 |
Time |
16:57 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-12-21 |
Time |
16:56 |
Sent To |
PC |
|
Notes |
2005-12-21 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED TO APPLY FOR STORM SHUTTERS | | UNDER A SEPARATE PERMIT AS AGREED ON | | PROVISO. APPLY AS SOON AS POSSIBLE TO | | AVOID DELAYS OR CONFLICTS GIVEN THE | | AMOUNT OF PERMIT APPLICATIONS THE CITY | | IS RECEIVING AT THIS TIME. | | | | 2- ENERGY CALCULATIONS SUBMITTED ARE FBC | | 2004 FORMS. PLANS WERE REVIEWED UNDER | | FBC 2001. REVISED AS REQUIRED. NEED FBC | | 2001 FORMS. | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL AS REQUIRED BY RULE 9B-72 FOR | | ATRIUM DOOR. SEE SPECIFICATIONS ON PLANS | | FOR SIZE AND SWING DIRECTION OF DOOR. | | | | 4- OWES $70.00 FOR REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-20 |
Time |
11:52 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-20 |
Time |
11:51 |
Sent To |
PC |
|
Notes |
2005-07-19 00:00:00 | BUILDING REVIEW PROVISO: | | 1- SHUTTERS UNDER SEPARATE PERMIT. | | 2- NEED WORST CASE SCENARIO ENERGY CALCS | | 3- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT FRONT PORCH TO MATCH | | DETAILS 4/D1 AND 5/D1. | | 4- REVISE NAIL SIZE FOR HUS26 CONNECTOR. | | 5- SPECIFY SIZE AND ANCHORS FOR WINDOW | | MULLION AT GREAT ROOM LARGE WINDOWS. | | 6- RE-SUBMIT PRODUCT APPROVAL FOR: | | A) 1 HR FIRE RATED ATRIUM DOOR ASSEMBLY | | B) FIXED WINDOWS. | | C) SINGLE HUNG WINDOWS. | | D) ROOF TILE. | | E) LARGE WINDOW MULLION AT GREAT ROOM. | | 7- PROVIDE CLEAR DOOR/WINDOW SCHEDULE. | | DON'T MIX DOOR AND WINDOW SYMBOLS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
20:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
20:25 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | REDLINED; | | | | GRND ROD SHALL BE A MIN OF 8' 250.52A5 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-07-06 |
Time |
16:29 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-07-06 |
Time |
15:47 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-21 |
Time |
18:25 |
Sent To |
B |
|
Notes |
2006-03-21 00:00:00 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-14 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-14 |
Time |
13:59 |
Sent To |
B |
|
Notes |
2006-03-14 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:57 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
14:08 |
Sent To |
B |
|
Notes |
2005-11-15 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-06 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-06 |
Time |
10:09 |
Sent To |
E |
|
Notes |
2005-07-06 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-20 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-06-24 |
Time |
13:59 |
Sent To |
|
|
Notes |
2005-06-24 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-07-11 |
Time |
12:04 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-07-11 |
Time |
12:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-07-06 |
Time |
17:07 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-07-06 |
Time |
17:07 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-05 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-07-05 |
Time |
13:51 |
Sent To |
I |
|
Notes |
|
|