Plan Review Details - Permit 05061053
Plan Review Stops For Permit 05061053
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-07-14 Cont ID  
Sent By mjacobs Date 2005-07-14 Time 09:03 Rev Time 1.00
Received By mjacobs Date 2005-07-14 Time 07:34 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-07-05 Cont ID  
Sent By rbrown Date 2005-07-05 Time 08:28 Rev Time 0.00
Received By RBROWN Date 2005-07-14 Time 07:34 Sent To  
Notes
2005-07-05 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) FBC 1507.4.3ROOF TILE UNDERLAYMENT.
 PROPOSED ADHESIVE SET CONCTRETE TILE.
 THE SUBMITTED EAVE DETAIL SHOWS
 "SELF-ADHERED UNDERLAYMENT OVER EXISTING
 PLYWOOD DECK".NO PRODUCT APPROVAL WAS
 SUBMITTED FOR THE SPECIFIED POLYGLASS
 POLYSTICK TU.REFERENCE TO THE FLORIDA
 STATE PRODUCT APPROVAL LISTING AND THE
 INSTALLATION INSTRUCTIONS ON THE
 ASSOCIATED MIAMI-DADE PRODUCT APPROVAL
 NOA# 02-0603.08 SHOWS THAT POLYSTICK TU
 IS TO BE APPLIED OVER A BASE SHEET OF
 "ONE OR MORE PLIES OF ASTM D 226 TYPE II
 OR ASTM D 2626" NAILED AND TIN-CAPPED AT
 12" O.C., 6" O.C. AT LAPS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-15 Cont ID  
Sent By mjacobs Date 2005-06-15 Time 14:03 Rev Time 0.75
Received By mjacobs Date 2005-06-15 Time 14:03 Sent To PC
Notes
2005-06-15 00:00:00 
 1) THE PRODUCT APPROVALS SUBMITTED ALONG
 WITHE THE FL#(NUMBER) DOES NOT
 CORRISPOND WITH WHAT'S ON THE STATE WEB
 SITE. PLEASE PROVIDE A STATE WIDE
 PRODUCT WITH THE CORRECT FL NUMBER.THE
 FL (506) NUMBER IS FOR A DIFFERENT
 REPORT.
  
 BUILDING PLAN REVIEW
 MYRON JACOBS.
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected].

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-12 Cont ID  
Sent By adarroug Date 2005-07-12 Time 16:20 Rev Time 0.00
Received By adarroug Date 2005-07-12 Time 16:20 Sent To B
Notes
2005-07-12 00:00:00TO "MJACOBS" DESK/RESUB


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved