Plan Review Details - Permit 05060844
Plan Review Stops For Permit 05060844
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-12 Cont ID  
Sent By jwitmer Date 2005-08-12 Time 12:20 Rev Time 0.55
Received By jwitmer Date 2005-08-12 Time 12:13 Sent To PC
Notes
2005-08-12 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05060844
 ADD: 10567 HOLLOW BAY TERRACE
 CONT: VAN KIRK & SONS
 TEL: (954)755-4400
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 POOL REVIEW
 ACTION: ISSUED
  
  
  
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE
 PROVIDED WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH
 424.2.17.1.14.
 424.2.17.1.15 CHILD SAFETY BARRIER
  
  
 2)13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-02 Cont ID  
Sent By shill Date 2005-07-02 Time 13:59 Rev Time 0.50
Received By shill Date 2005-07-02 Time 13:59 Sent To PC
Notes
2005-07-02 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)PROVIDE A REASONABLE VALUE OR AN
 ESTIMATED VALUE WILL BE ASSESSED BASED
 ON MARSHALL & SWIFT.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-12 Cont ID  
Sent By btrobaug Date 2005-08-12 Time 11:05 Rev Time 0.33
Received By btrobaug Date 2005-08-12 Time 11:05 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-22 Cont ID  
Sent By btrobaug Date 2005-06-22 Time 17:27 Rev Time 0.33
Received By btrobaug Date 2005-06-22 Time 17:24 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-07-21 Cont ID  
Sent By adarroug Date 2005-07-21 Time 10:11 Rev Time 0.00
Received By adarroug Date 2005-07-21 Time 10:11 Sent To P
Notes
2005-07-21 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-10 Cont ID  
Sent By shill Date 2005-06-10 Time 13:33 Rev Time 0.00
Received By shill Date 2005-06-10 Time 13:33 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-03 Cont ID  
Sent By jleech Date 2005-08-03 Time 14:00 Rev Time 0.50
Received By jleech Date 2005-08-03 Time 14:00 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-06-28 Cont ID  
Sent By jleech Date 2005-06-28 Time 10:35 Rev Time 1.25
Received By jleech Date 2005-06-28 Time 10:35 Sent To B
Notes
2005-06-28 00:00:00DENIED;
 PLEASE ADJUST YOUR NOTES, DETAILS OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW.
 1.COMPLY WITH FBC-2001 SEC 424.2 PRIVATE
 SWIMING POOLS. (NOTES)
 2.FBC-2001 SEC. 424.2.6.1 ENGINEER
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92 AND NSPI-5 (NOTES)
 3.FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA. BLDG. CODE, PLUMBING. THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND
 REMOVAL. SEC. 424.2.8.2 (NOTES)
 FILL WAY VALVES SHALL BE INSTALLED TO
 INSURE PROPER FUNCTION OF THE FILTRATION
 SYSTEM SEC. 424.2.8.3 WHERE CHECK VALVES
 ARE INSTALLED THEY SHALL BE OF THE SWING
 OR VERTICAL CHECK PATTERNS SEC.424.2.8.4
 4.FBC-2001 424.2.9 WATER SUPPLY LOCAL
 ORD.#2853-95 BACKFLOW REQUIRED ON WATER
 SEVICE. (NOTES)
 5.FBC-2001 424.2.12.1 PRESSURE TEST.
 PERR MANUFACTURE RECOMMENDATIONS NO AIR
 TEST SHALL BE SHALL BE APPROVED FOR PVC
 PIPE AND FITTINGS. (NOTES)
 6.FBC-2001 SEC.424.2.13.2 JOINTS AND
 FITTINGS FBC PLBG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPE-ING (NOTES)
 7.424.2.14.1 SWIMING POOL HEATERS SHALL
 BEAR THE LABLE OF A RECOGNIZEDTESTING
 AGENCY. 424.2.14.2 POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN BPUMP
 IS SHUT OFF. 424.2.14.4 ALL WATER HEATER
 SHALL BE INSTALLED WITH FLANGES OR
 UNIONS CONNECTIONS ADJACENT TO
 HEATERS.(NOTES)
 8.FBC.2001 424.2.15 GAS PIPING SHALL
 COMPY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (NOTES)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2005-06-21 Cont ID  
Sent By mmclean Date 2005-06-21 Time 12:05 Rev Time 0.00
Received By mmclean Date 2005-06-21 Time 12:05 Sent To I
Notes
***NONE***