Plan Review Stops For Permit 05060722 |
Review Stop |
G |
GAS REVIEW |
Rev No |
5 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-15 |
Time |
16:36 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-15 |
Time |
16:36 |
Sent To |
PC |
|
Notes |
2006-05-15 00:00:00 | REVISION: CHANGED SIZE OF FUTURE | | GENERATOR FROM 1-1/4" TO 1" AND MADE | | UPSTAIRS FIREPLACE A FUTURE FIREPLACE | | | | ******PROVISO****** | | FUTURE GENERATOR GAS PIPING AT OWN RISK, | | SEPERATE GEN/RES PERMIT REQUIRED WITH | | ZONING APPROVAL OF GENERATOR PLACEMENT. | | NOTE:PER 404.12 OUTLET CLOSURES. GAS | | OUTLETS THAT DO NOT CONNECT TO | | APPLIANCES SHALL BE CAPPED GAS TIGHT. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-21 |
Time |
16:35 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-04-21 |
Time |
16:34 |
Sent To |
PC |
|
Notes |
2006-04-21 00:00:00 | REVISION: ADDED 2"X2"X1-1/4" TEE, 1-1/4" | | VALVE, 1-1/4" NIPPLE AND CAP FOR FUTURE | | GENERATOR. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-17 |
Time |
13:10 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-04-17 |
Time |
13:10 |
Sent To |
PC |
|
Notes |
2006-04-17 00:00:00 | ******REVISION DENIED****** | | REFERENCE: FBC-2004 FUEL GAS, AND CITY | | OF WEST PALM BEACH, AMENDMENTS TO | | FBC-2004, CHAPTER 1, ADMINISTRATION: | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLAN REVIEW FOR THE GAS REVISION: | | | | 1. PER CITY AMENDMENTS SECTION 106 | | CONSTRUCTION DOCUMENTS: 106.1 SUBMITTAL | | DOCUMENTS. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS, AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNITURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | 2. PER FBC 2004 FUEL GAS, INDICATE ON | | THE REVISION THE TYPE OF PIPING MATERIAL | | BEING USED. | | 3. PLEASE CLARIFY DELIVERY PRESSURE, RE- | | VISION INDICATES 2.5 LB PSI. DELIVERY | | PRESSURE IS EITHER A 0.5 LB PSI OR A 2 | | LB PSI SYSTEM. CLEARLY INDICATE ON THE | | DRAWING THE DELIVERY PRESSURE. NOTE: IF | | SYSTEM IS BEING REVISED TO A 2 LB PSI | | SYSTEM SUBMIT MANUFACTURE SHEETS FOR 2LB | | PSI REGULATORS, AND INDICATE THEIR | | LOCATION ON THE DRAWING PER FBC-2004 | | FUEL GAS SEC. 402.2 | | 4. FUTURE GENERATOR INDICATED ON DRAWING | | NEEDS TO HAVE A SHUT OFF VALVE AND A | | HARD CAP (PRESSURE CAP) INDICATED ON | | DRAWING. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-07-18 |
Time |
08:16 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-07-18 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2005-06-23 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-06-23 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-06-23 |
Time |
10:35 |
Sent To |
PC |
|
Notes |
2005-06-24 00:00:00 | DENIED | | GAS: PLAN REVIEW:FBC 2001 FUEL GAS | | FBC 2001 CHAPTER 1 | | | | GENERATOR PERMITTING CHECKLIST | | (1 ) NO PERMIT PERTAINING TO A GENERATOR | | SHALL BE ISSUED UNTIL AN APPLICATION FOR | | THE GENERATOR IS APPLIED FOR. | | A REVIEW FOR THE GENERATOR IS REQUIRED. | | BUILDING,ELECTRIC,MECHANICAL, FUEL GAS, | | AND ZONING. | | THE BUILDING: REVIEW WILL BE FOR SLAB | | AND ANCHORING, FBC WIND LOADS 140 MPH. | | ELECTRICAL: RISER DRAWING, SIZE OF | | TRANSFERE SWITCH AND GENERATOR, SUBMIT | | MANFACTURES SPECIFICATION SHEETS. | | MECHANICAL: EXHAIST SYSTEM, CLEARANCES. | | FUEL GAS: GAS PERMIT APPLICATION | | REQUIRMENTS. | | ZONING: SITE SURVEY, SHOW LOCATION OF | | GENERATOR. | | (2) SECTION 104.2.1 | | ALL INFORMATION, DRAWINGS | | SPECIFICATIONS AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | (3)DISCRIPTION OF WORK ON THE | | APPLICATION: DESCRIBE PROJECT IN DETAIL. | | (3) SHOW THE TYPE OF PIPING MATERIAL | | BEING INSTALLED. | | (4)TYPE OF GAS ( L-P OR NATURAL) | | (5)SUBMIT A DETAIL SHOWING THE TYPE, | | LOCATION, SIZE AND TERMATION OF THE GAS | | VENTS PER. | | SEC 502 THRU 506. | | (6) SUBMIT MANFACTURE SHEETS FOR 2# PSI | | GAS REGULATORS, AND LOCATION. | | END OF COMMENTS, QUESTIONS CONTACT | | PAUL SCHMITZ 561-805-6692 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-21 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-21 |
Time |
09:52 |
Sent To |
G |
|
Notes |
2006-04-21 00:00:00 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-04-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-11 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-11 |
Time |
08:55 |
Sent To |
G |
|
Notes |
2006-04-11 00:00:00 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-01 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-01 |
Time |
15:04 |
Sent To |
G |
|
Notes |
2005-07-01 00:00:00 | TO "G" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-08 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-08 |
Time |
15:41 |
Sent To |
G |
|
Notes |
|
|