Plan Review Stops For Permit 05060670 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-28 |
Time |
08:00 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2006-02-28 |
Time |
08:00 |
Sent To |
P |
|
Notes |
2006-02-28 00:00:00 | DRAWNG A-1.0 SUBMITTAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-14 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2006-02-14 |
Time |
11:08 |
Sent To |
P |
|
Notes |
2006-02-14 00:00:00 | BUILDING REVISION CHECKLIST: | | 1- PLUMBING RISER DIAGRAM ON SHEET A-1.0 | | WAS CROSSED OUT BY HAND TO AVOID ROUTING | | FOR PLUMBING REVIEW. THE PLUMBING RISER | | DIAGRAM IS PART OF THE CONSTRUCTION | | DOCUMENTS SUBMITTED BY THE ARCHITECT AND | | IT CAN'T BE ARBITRARILY CROSSED OUT. | | RE-SUBMIT CLEAN DRAWING TO ROUTE TO | | PROPER TRADES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-01-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-19 |
Time |
12:55 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-01-19 |
Time |
12:55 |
Sent To |
PC |
|
Notes |
2006-01-19 00:00:00 | BUILDING REVISION CHECKLIST: | | 1- PLUMBING RISER DIAGRAM IN DRAWING | | A-1.0 WAS CROSSED OUT. PLUMBING RISER | | DIAGRAM IS PART OF THE CONSTRUCTION | | DOCUMENTS AND IT CAN'T BE CROSSED OUT. | | RE-SUBMIT CLEAN DRAWINGS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-10 |
Time |
09:04 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2006-01-04 |
Time |
11:26 |
Sent To |
PC |
|
Notes |
2006-01-04 00:00:00 | ENERGY CALCULATIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-09 |
Time |
17:47 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-12-09 |
Time |
17:17 |
Sent To |
PC |
|
Notes |
2005-12-09 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | 1- ENERGY CALCULATIONS SUBMITTED ARE FBC | | 2004. NEED TO PROVIDE FBC 2001 FORMS, | | SINCE PLANS WERE REVIEWED UNDER FBC | | 2001. | | | | 2- OWES $80.00 FOR REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-20 |
Time |
16:23 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-20 |
Time |
16:22 |
Sent To |
PC |
|
Notes |
2005-07-20 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | 2- NEED WORST CASE SCENARIO ENERGY CALCS | | 3- CLARIFY DOOR/WINDOW SCHEDULE. DON'T | | MIX TOGETHER DOOR/WINDOW SYMBOLS USED. | | 4- REVISE DETAIL 5/D1: CONNECTOR HTS20 | | CAN'T SUPPORT BEAM. | | 5- TRUSS ANCHOR SCHEDULE: UPDATE HUS26 | | NAIL SIZE. SEE LATEST CATALOGUE. | | 6- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT ENTRY PORCH TO MATCH | | DETAILS 5/D1 AND 6/D1. | | 7- RE-SUBMIT PRODUCT APPROVAL FOR: | | A) ROOF TILE. | | B) SINGLE HUNG WINDOWS. | | C) FIXED WINDOWS. | | 8- SHEET A-5 SHEAR VALUES NOTE: PROVIDE | | HAND CALCULATIONS. WHY USING TIMBER | | CONSTRUCTION MANUAL FOR TAPCONS VALUES? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-30 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-30 |
Time |
11:39 |
Sent To |
PC |
|
Notes |
2006-03-30 00:00:00 | REDLINED 210.70 FOR REAR EGRESS. | | REDLINED OPC FOR CU #1, |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-13 |
Time |
19:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-13 |
Time |
19:51 |
Sent To |
PC |
|
Notes |
2006-03-13 00:00:00 | *** UNSAT *** | | | | ** PLEASE SEE ITEMS BELOW HAVE REDLINED | | ON THE LAST TWO REVIEWS AND REVISIONS | | SUBMITTED, YET THESE ITEMS ARE STILL NOT | | BEING CORRECTED. | | | | 1)NOTE: PLEASE VERIFY OCP FOR CU, SHOWS | | 9.8KW, 40A OCP. PLEASE SEE MIN OCP | | REQUIRED TO BE SIZED PER 430 | | PLEASE ADJUST CONDUCTOR SIZE IF NEEDED. | | 240.4. 310.16 | | | | 2)NOTE: PLEASE SEE A MIN 8' GROUND ROD | | IS REQUIRED PER 250.52A5 | | | | 3)NOTE: PLEASE VERIFY MIN OCP FOR AHU#2, | | PER 424.3B, MIN OCP 125%. | | PLEASE ADJUST. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-09 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-09 |
Time |
10:00 |
Sent To |
B |
|
Notes |
2006-02-09 00:00:00 | ** REDLINED ** | | | | VERIFY OCP FOR CU, SHOWS 9.8KW, 40A OCP | | | | MIN 8' GROUND ROD REQUIRED PER 250.52A | | | | VERIFY MIN OCP FOR AHU#2, PER 424.3B, | | MIN OCP 125%. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
19:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
19:16 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | REDLINED: | | | | | | MIN OCP FOR AHU #2 125%. (60A)#6 | | | | MIN OF 8' GRND ROD PER 250.52A5 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-01-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-10 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-10 |
Time |
08:42 |
Sent To |
B |
|
Notes |
2006-01-10 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE PANEL "A" IS MISSING | | LOAD FROM PANEL "B"AND "C". | | PLEASE ALSO SEE LOADS ON PANEL "B" AND | | "C". SOME ARE SHOWN WITH 83 KW, 96, KW | | ETC. | | PLEASE ADJUST LOADS AND CALCUALTIONS. | | 220, 215.5 | | | | 2)NOTE: PLEASE SEE MISSING RECEPT PER | | 210.52 | | | | 3)NOTE: PLEASE SEE A RECEPT IS STILL | | BEING SHOWN IN THE LOCATION OF THE NEW | | SLIDING GLASS DOORS.?? THIS HAS BEEN | | REMOVED ON SOME OTHER PLANS, HOWEVER NOT | | THIS PLAN. | | PLEASE SEE THIS WOULD BE A TRIPPING | | HAZARD AND NOT BE PERMITTED IN THIS | | EGRESS LOCATION. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-24 |
Time |
07:56 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-06-24 |
Time |
07:56 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-29 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-29 |
Time |
14:21 |
Sent To |
E |
|
Notes |
2006-03-29 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-10 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-10 |
Time |
10:27 |
Sent To |
E |
|
Notes |
2006-03-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-03 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-03 |
Time |
12:03 |
Sent To |
E |
|
Notes |
2006-02-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:55 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-30 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-30 |
Time |
09:30 |
Sent To |
E |
|
Notes |
2005-12-30 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
11:00 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
14:12 |
Sent To |
B |
|
Notes |
2005-11-15 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-21 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-21 |
Time |
10:38 |
Sent To |
E |
|
Notes |
2005-06-21 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-20 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-06-10 |
Time |
09:40 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-20 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-07-20 |
Time |
16:52 |
Sent To |
|
|
Notes |
2005-07-20 00:00:00 | PLANS APROVED AND STAMPED BY PATTY | | KRAUSS ON 7-6-05. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-28 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-02-28 |
Time |
18:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-16 |
Time |
14:52 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2006-02-16 |
Time |
14:52 |
Sent To |
B |
|
Notes |
2006-02-16 00:00:00 | PLESE DO NOT "X" OUT PARTS OF THE PLANS. | | IF REVISIONS ARE REQUIRED THE PLANS NEED | | TO BE REVIEWED AND RESTAMPED BY ALL | | TRADES INVALVED. | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-25 |
Time |
06:55 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-06-25 |
Time |
06:55 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-20 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-20 |
Time |
14:45 |
Sent To |
I |
|
Notes |
|
|