Plan Review Details - Permit 05060666
Plan Review Stops For Permit 05060666
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-01-26 Cont ID  
Sent By jgomez Date 2006-01-26 Time 18:00 Rev Time 0.33
Received By jgomez Date 2006-01-26 Time 17:50 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-01-04 Cont ID  
Sent By jgomez Date 2006-01-04 Time 12:59 Rev Time 0.50
Received By jgomez Date 2006-01-04 Time 12:59 Sent To P
Notes
2006-01-04 00:00:00BUILDING SUBMITTAL CHECKLIST:
 1- ENERGY CALCULATIONS SUBMITTED ARE
 DONE USING FBC 2004 FORMS. PLANS WERE
 REVIEWED UNDER THE FBC 2001. PROVIDE
 ENERGY CALCULATIONS USING FBC 2001
 FORMS.
  
 2- OWES $100.00 FOR REVISION FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-07-25 Cont ID  
Sent By jgomez Date 2005-07-25 Time 15:51 Rev Time 2.00
Received By jgomez Date 2005-07-25 Time 15:51 Sent To PC
Notes
2005-07-25 00:00:00BUILDING REVIEW PROVISO:
 1-SHUTTERS UNDER A SEPARATE PERMIT.
 2- NEED WORST CASE SCENARIO ENERGY CALCS
 3- CLARIFY DOOR WINDOW/SCHEDULE. DON'T
 MIX TOGETHER DOOR/WINDOW SYMBOLS.
 4- REVISE DETAIL 5/D1: HTS20 CONNECTOR
 CAN'T SUPPORT GIRDER TRUSS.
 5- UPDATE HUS26 NAIL SIZE.SEE CATALOGUE
 6- REVISE CONNECTOR SPECIFIED AT ENTRY
 PORCH TO MATCH DETAILS 5/D1 AND 6/D1.
 7- RE-SUBMIT PRODUCT APPROVAL FOR:
 A)ROOF TILE, B)SINGLE HUNG WINDOWS,
 C)FIXED WINDOWS.
 8- SHEET A-5 SHEAR VALUES NOTE: PROVIDE
 HAND CALCULATIONS. WHY USING TIMBER
 CONSTRUCTION MANUAL FOR TAPCON VALUES?

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-18 Cont ID  
Sent By dpalmer Date 2006-03-18 Time 12:18 Rev Time 0.00
Received By dpalmer Date 2006-03-18 Time 12:18 Sent To PC
Notes
2006-03-18 00:00:00CU #1 , TO VIF OCP/ KW.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-17 Cont ID  
Sent By dpalmer Date 2006-01-17 Time 14:24 Rev Time 0.00
Received By dpalmer Date 2006-01-17 Time 14:24 Sent To PC
Notes
2006-01-17 00:00:00REDLINED,
  
  
 1)MISSING RECEPT 210.52
  
 2)PLANS SHOW BATH RM CIRCUITED AS #25,
 HOWEVER PANEL SCHEDULE SHOWS THIS AS
 COOKTOP.
  
 3)MIN OCP FOR AHU#2, 125% 424.3B
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-24 Cont ID  
Sent By dpalmer Date 2005-06-24 Time 07:47 Rev Time 0.30
Received By dpalmer Date 2005-06-24 Time 07:47 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-03-14 Cont ID  
Sent By adarroug Date 2006-03-14 Time 14:09 Rev Time 0.00
Received By adarroug Date 2006-03-14 Time 14:09 Sent To E
Notes
2006-03-14 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-22 Cont ID  
Sent By adarroug Date 2006-01-22 Time 12:50 Rev Time 0.00
Received By adarroug Date 2006-01-22 Time 12:50 Sent To B
Notes
2006-01-22 00:00:00TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-06 Cont ID  
Sent By adarroug Date 2006-01-06 Time 09:55 Rev Time 0.00
Received By adarroug Date 2006-01-06 Time 09:55 Sent To E
Notes
2006-01-06 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-29 Cont ID  
Sent By adarroug Date 2005-12-29 Time 10:49 Rev Time 0.00
Received By adarroug Date 2005-12-29 Time 10:48 Sent To B
Notes
2005-12-29 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-21 Cont ID  
Sent By adarroug Date 2005-06-21 Time 10:39 Rev Time 0.00
Received By adarroug Date 2005-06-21 Time 10:39 Sent To E
Notes
2005-06-21 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-25 Cont ID  
Sent By shill Date 2005-07-25 Time 15:59 Rev Time 0.00
Received By jgomez Date 2005-06-10 Time 09:35 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-07-25 Cont ID  
Sent By jgomez Date 2005-07-25 Time 15:49 Rev Time  
Received By jgomez Date   Time   Sent To  
Notes
2005-07-25 00:00:00PASSED BY PATTY KRAUSS 7/6/05. SEE
 PLANS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-01-06 Cont ID  
Sent By jleech Date 2006-01-06 Time 10:22 Rev Time 0.00
Received By jleech Date 2006-01-06 Time 10:22 Sent To  
Notes
2006-01-06 00:00:00SAN.RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-06-25 Cont ID  
Sent By jleech Date 2005-06-25 Time 06:37 Rev Time 0.25
Received By jleech Date 2005-06-25 Time 06:37 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-06-20 Cont ID  
Sent By jgomez Date 2005-07-25 Time 15:59 Rev Time 0.00
Received By mmclean Date 2005-06-20 Time 14:24 Sent To I
Notes
***NONE***