Plan Review Stops For Permit 05060659 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-06 |
Time |
17:59 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-02-06 |
Time |
17:44 |
Sent To |
PC |
|
Notes |
2006-02-06 00:00:00 | ATRIUM DOOR REVISION AND PRODUCT | | APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-07 |
Time |
17:07 |
Rev Time |
0.75 |
Received By |
jgomez |
Date |
2005-12-07 |
Time |
17:07 |
Sent To |
PC |
|
Notes |
2005-12-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- ENERGY CALCULATIONS SUBMITTED ARE FBC | | 2004 FORMS. NEED TO PROVIDE FBC 2001 | | FORMS, SINCE PLANS WERE REVIEWED UNDER | | FBC 2001. | | | | 2- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR ATRIUM DOOR AS REQUIRED BY | | RULE 9B-72 OF DCA. | | ***NOTE: SEE PLANS FOR SIZE AND SWING | | DIRECTION OF DOOR. | | | | 3- OWES $70.00 FOR REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-22 |
Time |
11:31 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-09-22 |
Time |
11:31 |
Sent To |
PC |
|
Notes |
2005-09-22 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- ENERGY CALCS: ROBIN FROM KENCO COMM. | | CALLED TO SAY THAT ENERGY CALCS WILL BE | | CHANGED AGAIN FROM WORST CASE TO | | SPECIFIC HOUSE ORIENTATION. SUBMIT | | REVISED CALCS. | | | | 2- SEPARATE PERMIT FOR SHUTTERS IS NOT | | DONE YET. | | | | 3- REVISE ROOF FRAMING PLAN AT ENTRY | | PORCH AREA. CONCRETE BEAM DOESN'T EXTEND | | TO THE FOYER AREA. ALSO, KNEEWALL IS NOT | | CONCRETE EITHER. REVISE FRAMING PLANS | | AND SPECIFY CORRESPONDING CONNECTORS. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | 4- TRUSS ANCHOR SCHEDULE: REVISE NUMBER | | OF NAILS SPECIFIED FOR HUS26. SEE 2005 | | CATALOGUE. | | | | 5- PROVIDE 1 HR FIRE RATED DOOR AT | | ATRIUM WITH SWING AS SHOWN ON PLANS. | | | | 6- WINDOW MULLION SIZE SPECIFIED FOR | | FIXED WINDOWS AT GREAT ROOM DOESN'T | | RESIST THE DESIGN PRESSURES. REVISE AS | | REQUIRED. | | | | 7- PROVIDE PRODUCT APPROVAL FOR WINDOW | | MULLION SPECIFIED ABOVE FOR FIXED | | WINDOWS AT GREAT ROOM. | | | | ***NOTE: | | REVISED DRAWINGS WILL BE SUBJECT TO | | REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-26 |
Time |
10:32 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2005-07-26 |
Time |
10:32 |
Sent To |
PC |
|
Notes |
2005-07-26 00:00:00 | STAMPED PLANS BY PALM BEACH COUNTY FOR | | IMPACT FEES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
|
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-19 |
Time |
14:37 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-19 |
Time |
14:37 |
Sent To |
PC |
|
Notes |
2005-07-19 00:00:00 | BUILDING REVIEW PROVISO: | | 1- NEED WORST CASE SCENARIO ENERGY CALCS | | 2- SHUTTERS UNDER A SEPARATE PERMIT. | | 3- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT FRONT PORCH TO MATCH | | DETAILS 4/D1 AND 5/D1. | | 4- REVISE NAIL SIZE FOR HUS26 CONNECTOR. | | 5- SPECIFY SIZE AND ANHORS FOR MULLION | | AT LARGE WINDOWS IN GREAT ROOM AREA. | | 6- RE-SUBMIT PRODUCT APPROVAL FOR: | | A) 1 HR FIRE RATED ATRIUM DOOR ASSEMBLY. | | B) FIXED WINDOWS. | | C) SINGLE HUNG WINDOWS. | | D) ROOF TILE. | | E) WINDOW MULLION SPECIFIED FOR LARGE | | FIXED WINDOWS AT GREAT ROOM AREA. | | 7- PROVIDE CLEAR DOOR/WINDOW SCHEDULES. | | NO MIXING DOOR & WINDOW SYMBOLS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-28 |
Time |
18:30 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-28 |
Time |
18:26 |
Sent To |
PC |
|
Notes |
2006-02-28 00:00:00 | REV OK, STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
16:18 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | ********* UNSAT ********* | | | | 1)NOTE: PLEASE SEE OCP HAS NOW BEEN | | INCREASED FOR PANEL "B" TO 125A'S, | | HOWEVER PLEASE SEE RISER HAS NOT | | INCREASED PANEL, FEEDERS AND PANEL | | SCHEDULE ALSO SHOWS 100A. | | PLEASE CORRELATE , UPGRADE PANEL, | | FEEDERS ETC. | | | | 240.4,310.15B6, 215.5 ETC. | | | | 2)NOTE: PLEASE SEE MIN GRND ROD AT 8' | | PER 250.52A5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-24 |
Time |
07:52 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-24 |
Time |
07:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-02-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-24 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-24 |
Time |
09:48 |
Sent To |
E |
|
Notes |
2006-02-24 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
11:40 |
Sent To |
B |
|
Notes |
2006-02-06 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
13:10 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
09:13 |
Sent To |
B |
|
Notes |
2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
09:05 |
Sent To |
B |
|
Notes |
2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-24 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-24 |
Time |
10:44 |
Sent To |
B |
|
Notes |
2005-08-24 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-26 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-26 |
Time |
10:17 |
Sent To |
B |
|
Notes |
2005-07-26 00:00:00 | TO "JGOMEZ" DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-21 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-21 |
Time |
10:40 |
Sent To |
E |
|
Notes |
2005-06-21 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-19 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-06-10 |
Time |
09:37 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-06 |
Time |
10:42 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-07-06 |
Time |
10:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-25 |
Time |
06:43 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-06-25 |
Time |
06:43 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-19 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-20 |
Time |
14:19 |
Sent To |
I |
|
Notes |
|
|