Plan Review Stops For Permit 05060474 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-06 |
Time |
18:19 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-02-06 |
Time |
18:19 |
Sent To |
PC |
|
Notes |
2006-02-06 00:00:00 | ATRIUM DOOR AND ENERGY CALCS REVISION. | | PRODUCT APPROVALS. | | STILL NEED TO APPLY FOR SHUTTERS AS | | AGREED ON PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-06 |
Time |
07:53 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-12-06 |
Time |
07:53 |
Sent To |
PC |
|
Notes |
2005-12-06 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | 1- ENERGY CALCULATIONS SUBMITTED ARE FOR | | FBC 2004. NEED TO USE FBC 2001 FORM | | SINCE PLANS WERE REVIEWED UNDER FBC | | 2001. | | | | 2- NEED TO APPLY FOR SHUTTERS UNDER A | | SEPARATE PERMIT AS AGREED ON PROVISO. | | ***NOTE: APPLY EARLY TO AVOID DELAYS OR | | CONFLICTS GIVEN THE LARGE VOLUME OF | | APPLICATIONS SUBMITTED FOR PERMIT AT | | THIS TIME. | | | | 3- PROVIDE PRODUCT APPROVAL FOR ATRIUM | | DOOR THAT MATCHES ONE SPECIFIED ON | | PLANS. SEE PLANS FOR SIZE AND SWING OF | | DOOR. | | | | 4- OWES $70.00 REVISION FEES AS NOTED ON | | CHECKLIST DATED 9-22-05. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-22 |
Time |
12:06 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-09-22 |
Time |
12:05 |
Sent To |
PC |
|
Notes |
2005-09-22 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- | | BUILDING SUBMITTAL CHECKLIST: | | 1- ACCORDING TO ROBIN FROM KENCO COMM. | | ENERGY CALCS WILL BE REVISED AGAIN TO | | HOUSE SPECIFIC ORIENTATION. RE-SUBMIT | | REVISED ENERGY CALCS. | | | | 2- NEED TO APPLY FOR SHUTTERS PERMIT. | | | | 3- NEED TO REVISE ROOF FRAMING PLAN BY | | ENTRY PORCH ROOF. CONCRETE BEAM DOESN'T | | EXTEND ALL THE WAY TO THE FOYER AREA. | | ALSO, KNEEWALL IS NOT CONCRETE EITHER. | | REVISE AS REQUIRED AND SPECIFY | | CORRESPONDING TRUSS ANCHOR. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 4- TRUSS ANCHOR SCHEDULE: REVISE # OF | | NAILS FOR HUS26. SEE 2005 CATALOGUE. | | | | 5- WINDOW MULLION SPECIFIED FOR FIXED | | WINDOWS AT GREAT ROOM DOESN'T RESIST THE | | DESIGN PRESSURES. RE-REVISE AS REQUIRED. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | 6- PROVIDE PRODUCT APPROVAL FOR: | | A) 1 HR FIRE RATED ATRIUM DOOR WITH | | INSWING AS SHOWN ON PLANS. | | | | B) WINDOW MULLION SPECIFIED FOR FIXED | | WINDOWS AT GREAT ROOM | | | | ***NOTE: REVISION FEES WILL BE APPLIED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-18 |
Time |
11:28 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-18 |
Time |
11:28 |
Sent To |
PC |
|
Notes |
2005-07-18 00:00:00 | BUILDING REVIEW PROVISO: | | | | 1- REVISE ENERGY CALCULATIONS FOR WORST | | CASE SCENARIO FOR THIS MODEL. | | 2- SHUTTERS UNDER A SEPARATE PERMIT. | | 3- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT FRONT PORCH. SEE DETAILS 4 | | AND 5 OF SHEET D-1. | | 4- TRUSS ANCHOR SCHEDULE: REVISE NAIL | | SIZE FOR HUS26. SEE CATALOGUE. | | 5- SPECIFY SIZE AND ANCHORS FOR LARGE | | FIXED WINDOW AT GREAT ROOM. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 6- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: | | A) 1 HR FIRE RATED DOOR AT ATRIUM. | | B) FIXED WINDOWS. | | C) SINGLE HUNG WINDOWS. | | D) ROOF TILE. | | E) WINDOW MULLION AT GREAT ROOM WINDOWS. | | 7- CLARIFY WINDOW DOOR SCHEDULES | | ICLUDING SIMBOLS USED ON PLAN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
18:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
18:35 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | | | PLEASE SEE MIN GRND ROD 8' PER | | 250.52A5 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
17:04 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-15 |
Time |
17:04 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
09:38 |
Sent To |
B |
|
Notes |
2006-02-06 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:52 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
08:52 |
Sent To |
B |
|
Notes |
2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-24 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-24 |
Time |
18:13 |
Sent To |
B |
|
Notes |
2005-08-24 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-15 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-15 |
Time |
13:28 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | TO RES RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-07 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-07 |
Time |
13:11 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-17 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-17 |
Time |
15:49 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-18 |
Time |
09:43 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-06-18 |
Time |
09:43 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-06-14 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-14 |
Time |
17:53 |
Sent To |
I |
|
Notes |
|
|