Plan Review Stops For Permit 05060425 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-19 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2005-09-19 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-19 |
Time |
07:50 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-09-19 |
Time |
07:50 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-12 |
Time |
09:35 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-09-12 |
Time |
09:35 |
Sent To |
P |
|
Notes |
2005-09-12 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05060425 | | ADD: 10699 HOLLOW BAY TERR | | CONT: VAN KIRK & SONS | | TEL: (954)834-0435 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 3RD REVIEW | | ACTION: DENIED | | FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | 1) MISSING THE PERMIT APPLICATION | | | | 2) SUPPLY NEW POOL ENGINEERING SHEETS, | | INDICATE THEY ARE VOIDED? | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-12 |
Time |
09:30 |
Rev Time |
0.22 |
Received By |
jwitmer |
Date |
2005-09-12 |
Time |
09:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-07-07 |
Time |
17:12 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2005-07-07 |
Time |
17:11 |
Sent To |
PC |
|
Notes |
2005-08-12 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05060425 | | ADD: 7070 ISLA VISTA DR | | CONT: VAN KIRK & SONS | | TEL: (954)755-4402 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: REVIEWED | | | | | | | | BUILDING PROVISO: | | TO BE IN PLACE AT C.O.: | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE | | PROVIDED WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH | | 424.2.17.1.14. | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | | 2)13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-09-16 |
Time |
16:34 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-09-15 |
Time |
15:56 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-02 |
Time |
17:23 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-09-02 |
Time |
17:20 |
Sent To |
P |
|
Notes |
2005-09-02 00:00:00 | ****** UNSAT 3RD REVIEW ******** | | | | 1)NOTE: PLEASE SEE SAME COMMENTS AS TWO | | PREVIOUS REVIEWS BY MR. BILL TROBAUGH. | | | | PLEASE PROVIDE INFORMATION ON NEW SUB | | PANEL SHOWN ON ELECTRICAL WIRING | | DIAGRAM. | | PLEASE INCLUDE NEW FEEDERS, CONDUIT, OCP | | TO NEW PANEL AND WHERE POWER COMES FROM. | | PLEASE PROVIDE LOADS FOR NEW. | | | | 2)NOTE: PLEASE SEE A 4X FEE IS NOW | | ACCESSED DUE TO REPEAT COMMENTS FOR THE | | SAME CODE COMPLIANCE COMMENTS. THIS FEE | | IS REQUIRED PER 553.80(2)(B) WITH | | RESPECT TO THE DESIGN PROFESSIONAL. | | PLEASE KNOW IF PLANS COME BACK WITH | | ANY OF THE CODE COMMENTS NOT ADDRESSED | | ON NEXT REVIEW THE FEE WILL BE ACCESSED | | ONCE AGAIN. | | PLEASE SEE THE AMOUNT OF $445.44 IS | | REQUIRED TO BE PAID BEFORE RE-SUBMITTIAL | | OF PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-08-03 |
Time |
10:57 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-08-03 |
Time |
10:18 |
Sent To |
B |
|
Notes |
2005-08-03 00:00:00 | | | | | | | SAME COMMENTS AS PREVIOUS REVIEW: | | PLEASE SUBMIT DETAILS FOR THE PANEL | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | SERVICE. PANEL SHOWN DOES NOT APPEAR ON | | THE BUILDING PLAN ON FILE. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-06-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-16 |
Time |
11:52 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-16 |
Time |
11:33 |
Sent To |
P |
|
Notes |
2005-06-16 00:00:00 | PLEASE SUBMIT DETAILS FOR THE PANEL | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | SERVICE. PANEL SHOWN DOES NOT APPEAR ON | | THE BUILDING PLAN ON FILE. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-09-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-15 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-15 |
Time |
15:15 |
Sent To |
E |
|
Notes |
2005-09-15 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-02 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-02 |
Time |
10:29 |
Sent To |
E |
|
Notes |
2005-09-02 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-08-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-22 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-22 |
Time |
15:34 |
Sent To |
Z |
|
Notes |
2005-08-22 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-03 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-03 |
Time |
08:57 |
Sent To |
E |
|
Notes |
2005-08-03 00:00:00 | TO "BT" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-28 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-28 |
Time |
18:16 |
Sent To |
Z |
|
Notes |
2005-07-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-15 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-15 |
Time |
12:01 |
Sent To |
E |
|
Notes |
2005-06-15 00:00:00 | TO ELEC BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-08 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-08 |
Time |
09:20 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-09 |
Time |
13:56 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-09-09 |
Time |
13:56 |
Sent To |
B |
|
Notes |
2005-09-09 00:00:00 | NEW SHEETS RE-STAMP |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-22 |
Time |
17:21 |
Rev Time |
0.65 |
Received By |
kstevens |
Date |
2005-06-22 |
Time |
17:21 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-01 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-01 |
Time |
14:23 |
Sent To |
L |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-02 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-02 |
Time |
16:22 |
Sent To |
I |
|
Notes |
2005-08-02 00:00:00 | DENIED, | | 1. POOL SETBACK MUST BE 5FT IN REAR, | | FROM WATER'S EDGE TO PROPERTY LINE. | | 2. MUST PROVIDE TWO NEW COPIES OF | | SURVEY/PLANS REFLECTING THE REAR SETBACK | | FOR POOL. | | | | 2ND REQUEST | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-06-14 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-14 |
Time |
17:17 |
Sent To |
I |
|
Notes |
2005-06-14 00:00:00 | DENIED, | | 1. POOL SETBACKFOR REAR MUST BE A MIN | | OF 5FT. PLANS SHOWS 3'1". | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|