Plan Review Stops For Permit 05060145 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-11-15 |
Time |
09:47 |
Rev Time |
1.50 |
Received By |
mjacobs |
Date |
2005-11-15 |
Time |
08:02 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-10-14 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-10-14 |
Time |
16:30 |
Sent To |
PC |
|
Notes |
2005-10-14 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)PROVIDE ANCHORING INFORMATION FOR | | POOL EQUIPMENT. | | | | 2.)POOL SAFETY REQUIREMENTS ARE NOT ON | | THE PLAN, FBC424.2.17. | | | | 3.)PROVIDE A SPA DETAIL. | | | | 4.)PROVIDE A STEP AND HANDHOLD DETAIL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-21 |
Time |
09:39 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-06-21 |
Time |
09:39 |
Sent To |
PC |
|
Notes |
2005-06-21 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)PROVIDE A SHORING DETAIL FOR THE | | HOUSE FOUNDATION (SPA IS LESS THAN 5' | | FROM THE PORCH). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-11-14 |
Time |
12:25 |
Rev Time |
0.25 |
Received By |
btrobaug |
Date |
2005-11-14 |
Time |
12:06 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-11-14 |
Time |
12:05 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-09-29 |
Time |
16:05 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-14 |
Time |
14:52 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-06-14 |
Time |
14:47 |
Sent To |
P |
|
Notes |
2005-06-14 00:00:00 | | | THE POOL SPECS INDICATE A GAS HEATER, | | THE SCHEMATIC INTEGRATES A HEAT PUMP. | | PLEASE CORRELATE AND RESUBMIT FOR | | REVIEW. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-22 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-22 |
Time |
08:50 |
Sent To |
E |
|
Notes |
2005-10-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-29 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-29 |
Time |
09:21 |
Sent To |
E |
|
Notes |
2005-09-29 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-23 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-23 |
Time |
16:08 |
Sent To |
E |
|
Notes |
2005-09-23 00:00:00 | TO "Z"BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-14 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-14 |
Time |
11:24 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-03 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-03 |
Time |
15:51 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-11-14 |
Time |
18:46 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2005-11-14 |
Time |
18:46 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-06 |
Time |
07:32 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-10-06 |
Time |
07:32 |
Sent To |
B |
|
Notes |
2005-10-06 00:00:00 | DENIED; | | 1.PIPING DIAGRAM DOES NOT MATCH POOL | | LAYOUT. SPA PIPING MISSING, AND LION | | HEADS NOT SHOWN ON POOL DRAWING. | | 2ND REQUEST FOR NOTES; | | 2) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 3) FBC-2001 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-5. (ADD TO NOTES) | | 4) FBC-2001 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (SUBMITTAL) | | 5)FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON THE | | WATER SERVICE. (ADD TO NOTES) | | 6)FBC-2001 424.2.13.2 JOINTS AND | | CONNECTIONS, FBC PLUMBING SEC. 606.21, | | PURPLE PRIMER REQUIRED ON PVC PIPES AND | | FITTINGS. (ADD TO NOTES) | | 7.FBC-2001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT ARE REQUIRED. (ADD TO NOTES) | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-20 |
Time |
18:05 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2005-06-20 |
Time |
18:05 |
Sent To |
B |
|
Notes |
2005-06-20 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A. FOLLOWING INFORMATION REQUIRED ON | | PLANS: | | | | 1) COMPLY WITH FBC-2001 SEC 424.2 | | PRIVATE SWIMMING POOLS. (ADD TO NOTES). | | 2) FBC-2001 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-5. (ADD TO NOTES). | | 3) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES). | | 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON THE | | WATER SERVICE. (ADD TO NOTES). | | 5) FBC-2001 424.2.13.2 JOINTS AND | | CONNECTIONS, FBC PLMG SECT. 605.21, | | PURPLE PRIMER REQUIRED ON PVC PIPES AND | | FITTINGS. (ADD TO NOTES). | | 6) FBC-2001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT ARE REQUIRED. (ADD TO NOTES). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-28 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-28 |
Time |
18:33 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-06-13 |
Time |
19:03 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-13 |
Time |
19:03 |
Sent To |
I |
|
Notes |
2005-06-13 00:00:00 | DENIED, | | 1. POOL SETBACK FOR REAR MUST BE 5FT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|