Plan Review Stops For Permit 05051930 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-10-12 |
Time |
11:29 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-10-12 |
Time |
11:29 |
Sent To |
P |
|
Notes |
2005-10-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- AGREEMENT WITH ANDY CHARNOUBI FROM | | THE RIF GROUP WAS TO APPLY FOR SEPARATE | | PERMIT FOR ITEMS LISTED ON ITEM #1 OF | | PROVISO DATED 9-7-05. INFORMATION WAS | | SUBMITTED AS SUBMITTAL. THIS WASN'T THE | | AGREEMENT. NEED TO APPLY FOR SEPARATE | | PERMIT FOR THOSE ITEMS. | | | | 2- BBQ HOOD AND GRILL: A) BBQ HOOD: | | INFORMATION SUBMITTED DOESN'T SPECIFY | | ANYWHERE IF THE SPECIFIC SELECTED MODEL | | IS DESIGNED FOR OUTDOOR USE AS | | REQUESTED. THERE ARE SPECIFIC HOODS THAT | | ARE DESIGNED FOR OUTDOOR USE AND THOSE | | WERE THE SPECIFICATIONS REQUESTED TO | | SUBMIT. SEC. 104.2.1.2 CITY AMENDMENTNS | | TO FBC 2001. | | | | B) BBQ HOOD INFORMATION SUBMITTED | | DOESN'T MATCH MODEL SPECIFIED ON | | ARCHITECT'S PLANS. REVISE A REQUIRED. | | | | 3- AS STATED ON PROVISO DATED 9-7-05 | | REVISION FEES WILL APPLY TO REVISED | | PLANS. OWES $80.00 | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-07 |
Time |
13:22 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
2005-09-07 |
Time |
13:21 |
Sent To |
PC |
|
Notes |
2005-09-07 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- AS AGREED ON WITH G.C. SEPARATE | | PERMITS FOR SINGLE HUNG WINDOWS, FRENCH | | DOORS, 2X6 WINDOW MULLIONS, CASEMENT | | WINDOWS, SLIDING GLASS DOORS & SHUTTERS. | | 2- PROVIDE COMPLETE SPECS AND LISTING | | FOR BBQ HOOD FOR EXTERIOR USE AND | | SPECIFIC GRILL TO BE INSTALLED. | | 3-A) REVISE DRAWINGS TO CLARIFY IF USING | | CONCRETE OR CLAY TILE. SEE WALL SECTION | | AND ELEVATIONS. REVISION FEES APPLY. | | B) REVISE SHEET A1: COLUMNS AT LANAI ARE | | C4 NOT C2. REVISION FEES WILL APPLY. | | C) SHEET A3: SPECIFY CONNECTOR FOR | | GIRDER TRUSS RESTING ON (3)2X6 POST. | | REVISION FEES APPLY. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-15 |
Time |
14:14 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-08-15 |
Time |
14:14 |
Sent To |
PC |
|
Notes |
2005-08-15 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOC. | | | | 2- CLARIFY IF USING STORM SHUTTERS OR | | IMPACT GLAZING. THERE IS A NOTE SAYING | | THAT SHUTTERS WILL BE DONE UNDER | | SEPARATE PERMIT. BUT, PRODUCT APPROVALS | | SUBMITTED ARE FOR NON-IMPACT AND IMPACT | | GLAZING. PROVIDE COMPLETE PRODUCT | | APPROVALS FOR IMPACT OR FOR NON-IMPACT. | | | | 3- PROVIDE FLORIDA OR APPLY FOR LOCAL | | PRODUCT APPROVAL FOR SLIDING GLASS DOORS | | AS SHOWN ON PLANS. PRODUCT APPROVAL | | SUBMITTED IS FOR A DIFFERENT | | CONFIGURATION OF DOORS. | | | | 4- A) PROVIDE COMPLETE SPECS AND | | APPROVED LISTING FOR BBQ. INCLUDING | | MODEL SELECTED. | | B) PROVIDE SPECS AND APPROVED LISTING | | FOR HOOD TO BE USED OUTDOOR. | | | | 5- CLARIFY IF USING CEMENT OR CLAY TILE. | | ELEVATIONS CALL FOR CONCRETE ROOF TILE. | | TYP. WALL SECTION IN SHEET A6 CALLS FOR | | CLAY BARREL TILE AND PRODUCT APPROVAL | | SUBMITTED IS FOR CONCRETE TILE. CLARIFY. | | | | 6- PROVIDE PRODUCT APPROVAL FOR | | 2"X6"X1/8" MULLION. | | | | 7- PROVIDE COPY OF THE IMPACT FEES PAID | | RECEIPT. | | | | 8- SHEET A1: COLUMNS AT LANAI ARE C4, | | NOT C2. REVISE AS REQUIRED. | | | | 9- SHEET A3: SPECIFY CONNECTOR FOR | | GIRDER TRUSS RESTING ON (3)2X6 POST. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-07-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-07 |
Time |
17:47 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-07 |
Time |
17:47 |
Sent To |
Z |
|
Notes |
2005-07-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- SHEET T1: UPDATE GENERAL NOTES. SEE | | COMMENTS ON PLANS. | | | | 3- DESIGN PARAMETERS: WHY MINIMUM SOIL | | BEARING PRESSURE IS : NA? | | | | 4- PROVIDE COMPLETE SPECS AND LISTING | | FORBBQ DESIGNED TO BE INSTALLED IN | | PORCH. SEC. 104.2.1.2 CITY AMENDMENTS TO | | FBC 2001 AND SEC. 2808 FBC 2001. | | | | 5- PROVIDE UL LISTING AND SPECS FOR | | FIREPLACE. SEC. 2806 FBC 2001. | | | | 6- SHEET A1: FOOTING DETAIL BETWEEN GOLF | | CART AND THEATER DOESN'T MATCH DETAIL 5. | | REVISE AS REQUIRED. | | | | 7- DOOR LEADING DIRECTLY INTO A SLEEPING | | ROOM IS NOT ALLOWED. PREVIOUS PLANS | | SHOWED BUILT OUT FLOOR LEVELS AND | | THEATER CONFIGURATION. THIS PLAN SHOWS A | | ROOM WITH A CLOSET. PROVIDE THEATER SET | | UP OR CONSPICUOSLY WRITE UNDER THEATER | | THAT ROOM IS NOT DESIGNED FOR SLEEPING | | PURPOSES. SEC. 411.2.8 FBC 2001. | | | | 8- PROVIDE FULL BATHROOM WITH DOOR THAT | | ALLOWS 29" MIN. CLEAR OPENING AS | | REQUIRED BY SEC. 11-11 FBC 2001. | | | | 9- PLANS ARE SPECIFYING LOT 20. THIS | | PLANS ARE FOR LOT 3. REVISE AS REQUIRED. | | | | 10- REVISE/UPDATE ALL TRUSS ANCHOR | | SPECIFYING SAME SIZE AND NUMBER OF NAILS | | AS SHOWN ON CATALOGUE THAT WAS REVISED | | TO COMPLY WITH SEC. 1609.4.3 FBC 2001. | | OTHERWISE, PROVIDE TESTING & ENGINEERING | | FOR NAIL SIZE AND NUMBER THAT DIFFER | | FROM THOSE ALREADY TESTED AND PUBLISHED | | BY THE MANUFACTURER. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 11- CONNECTOR THD210 IS A WOOD TO WOOD | | CONNECTOR. SEE CATALOGUE FOR PROPER | | MASONRY CONNECTORS AND REVISE AS REQ'D. | | | | 12- CLARIFY WHY USING ONLY AN F | | CONNECTOR TO SUPPORT END OF GIRDER TRUSS | | ABOVE BEDROOM #3 ENTRY. SEE PLAN FOR | | COMMENTS. SPECIFY CALCULATED UPLIFT AT | | THIS POINT. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 13- CLEARLY SPECIFY MULLIONS AND ANCHORS | | FOR BIG FIXED WINDOWS AT LIVING ROOM | | THAT MEET THE CALCULATED DESIGN | | PRESSURES. SEE PRODUCT APPROVAL. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 14- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: | | A) SLIDING GLASS DOORS. DADE COUNTY NOA | | DOESN'T MATCH INFORMATION SUBMITTED FOR | | FLORIDA PRODUCT APPROVAL. | | | | B)WINDOW MULLIONS SPECIFIED. SEE | | COMMENT #13 ABOVE. | | | | C) CASEMENT WINDOWS: NEED THE FLORIDA | | PRODUCT APPROVAL. NOA ALONE IS NOT | | ACCEPTABLE. | | | | 15- SOIL TEST REPORT SUBMITTED IS FOR | | LOT 20. NEED ONE FOR LOT 3. | | | | 16- SURVEY SUBMITTED DOESN'T MATCH FLOOR | | PLANS. REVISE AS REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-24 |
Time |
07:56 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-10-24 |
Time |
07:49 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-14 |
Time |
17:09 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-07-14 |
Time |
17:02 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-07 |
Time |
13:31 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-07-07 |
Time |
11:50 |
Sent To |
PC |
|
Notes |
2006-07-07 00:00:00 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE RISER SHOWS #3 FEEDERS TO PANEL | | "C", THE SCHEDULE LISTS #6 ON A 100 AMP | | BREAKER. PLEASE CORRECT. NOTE PANEL "C" | | HAS A 87 AMP LOAD, 4.25 ON PANEL "A" | | SHEDULE/CALC. CORRECT CALC AND SCHEDULE. | | | | 2} THE RECEPTACLES ON THE KITCHEN ISLAND | | | | MUST BE GFI PER 210.8(A)(6). | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-11 |
Time |
13:21 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-11 |
Time |
13:16 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-18 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-18 |
Time |
15:29 |
Sent To |
E |
|
Notes |
2006-10-18 15:29:46 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-06-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-28 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-28 |
Time |
11:01 |
Sent To |
E |
|
Notes |
2006-06-28 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-06 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-06 |
Time |
15:36 |
Sent To |
B |
|
Notes |
2005-10-06 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-01 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-01 |
Time |
14:43 |
Sent To |
B |
|
Notes |
2005-09-01 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-02 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-02 |
Time |
09:30 |
Sent To |
B |
|
Notes |
2005-08-02 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-28 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-28 |
Time |
11:19 |
Sent To |
Z |
|
Notes |
2005-07-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-09 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-09 |
Time |
17:38 |
Sent To |
E |
|
Notes |
2005-06-09 00:00:00 | TO RES RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-11 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-01 |
Time |
09:39 |
Sent To |
|
|
Notes |
2005-06-01 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-16 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-16 |
Time |
17:42 |
Sent To |
P |
|
Notes |
2005-06-16 00:00:00 | PASS PRIVISO | | COMPLETE RETURN AIR IN GUEST ROOM. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-12-18 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-12-18 |
Time |
09:08 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-12-18 |
Time |
09:08 |
Sent To |
PC |
|
Notes |
2006-12-18 09:09:23 | REVISION: AS BUILT SANITARY RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-12 |
Time |
16:12 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-10-12 |
Time |
16:12 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-18 |
Time |
06:40 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-06-18 |
Time |
06:40 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-01 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-01 |
Time |
16:15 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-07-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-11 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-09 |
Time |
16:02 |
Sent To |
|
|
Notes |
2005-07-11 00:00:00 | DENIED, | | 1. SURVEY DOES NOT MATCH PLANS. | | 2. LOT IS NOT INCLUDING IN THE MINOR | | AMENDMENT FOR ZERO LOT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 | 2005-06-09 00:00:00 | ZONING WILL REVIEW LAST. NEED TO HAVE | | GRACE REVIEW REGARDING THE REAR SETBACK. |
|
|