Plan Review Stops For Permit 05051929 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-11-14 |
Time |
17:18 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-11-14 |
Time |
17:18 |
Sent To |
PC |
|
Notes |
2005-11-14 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- A) NEED TO PROVIDE COMPLETE | | INFORMATION FOR IMPACT SLIDING GLASS | | DOORS UNDER A SEPARATE PERMIT AS AGREED | | ON PROVISO DATED 9-12-05. SEE ATTACHED | | COPY. | | | | B) SLIDING GLASS DOORS NOA IS STILL | | MISSING SOME DRAWINGS. PROVIDE COMPLETE | | SET OF DRAWINGS. | | | | 2- PROVIDE BBQ SPECS AND LISTING | | SPECIFICALLY FOR OUTDOOR USE. | | | | 3- OWES $60.00 FOR REVISION FEES AS | | NOTED ON PROVISO DATED 9-12-05. SEE | | ATTACHED COPY. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-12 |
Time |
08:49 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-09-12 |
Time |
08:49 |
Sent To |
PC |
|
Notes |
2005-09-12 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- PROVIDE INFORMATION FOR SLIDING GLASS | | DOORS UNDER A SEPARATE PERMIT. | | 2- NEED INFO FOR BBQ HOOD FOR EXTERIOR | | USE AND SPECIFIC GRILL TO BE USED. | | 3- SHEET A3: SPECIFY CONNECTOR FOR | | GIRDER TRUSS RESTING ON (3)2X6 POST BY | | MASTER BEDRM VEST. REVISION FEES APPLY. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-15 |
Time |
09:50 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-08-15 |
Time |
09:50 |
Sent To |
PC |
|
Notes |
2005-08-15 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- SLIDING GLASS DOORS: A) BUILDING | | OFFICIAL IS IN THE PROCESS OF REVIEWING | | APPLICATION FOR LOCAL PRODUCT APPROVAL. | | CONTACT LUIS MARTINEZ AT 805-6710 FOR | | LOCAL PRODUCT APPROVAL QUESTIONS. | | | | B) DADE COUNTY NOA SUBMITTED IS MISSING | | DRAWINGS. PROVIDE COMPLETE PACKAGE. | | | | 2- A) PROVIDE COMPLETE SPECS AND | | APPROVED LISTING FOR HOOD TO BE USED | | OUTDOORS. INFORMATION SUBMITTED DOESN'T | | SPECIFY IF HOOD CAN BE INSTALLED | | OUTSIDE. SEC. 104.2.1.2 CITY AMENDMENTS | | TO FBC 2001. | | | | B) PROVIDE COMPLETE SPECS AND APPROVED | | LISTING FOR GRILL TO BE INSTALLED. | | INCLUDE MODEL TYPE ETC. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | | | 3- NEED RECORDED NOC. | | | | 4- SHEET A3: SPECIFY CONNECTOR FOR | | GIRDER TRUSS RESTING ON (3)2X6 POST BY | | MASTER BEDROOM VESTIBULE. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-12 |
Time |
11:20 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-12 |
Time |
11:19 |
Sent To |
Z |
|
Notes |
2005-07-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- UPDATE GENERAL NOTES IN SHEET T1. SEE | | CHAPTER 19 AND 35 FBC 2001 FOR PROPER | | STANDARD REFERENCE AND EDITION. ALSO, | | SEE SEC. 2405.2 FBC 2001 AND REVISE | | SAFETY GLAZING NOTE AS REQUIRED. | | | | 3- DESIGN PARAMETERS: WHY MINIMUM SOIL | | BEARING PRESSURE IS : NA?. | | | | 4- PROVIDE COMPLETE BBQ SPECS AND | | LISTING FOR INSTALLATION IN PORCH. SEC. | | 2808 FBC 2001. | | | | 5- FOOTING BETWEEN GARAGE AND CLUB ROOM | | DON'T MATCH DETAIL 5. REVISE AS REQUIRED | | | | 6- REVISE/UPDATE ALL TRUSS ANCHORS NAIL | | SIZE AND NUMBER TO MATCH CATALOGUE THAT | | WAS REVISED TO COMPLY WITH SEC. 1609.4.3 | | FBC 2001. PROVIDE TESTING & ENGINEERING | | FOR TYPE AND NUMBER OF NAILS THAT DIFFER | | FROM THOSE TESTED AND PUBLISHED BY THE | | MANUFACTURER. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 7- CONNECTOR THD210 IS A WOOD TO WOOD | | CONNECTOR. SEE CATALOGUE FOR PROPER | | MASONRY CONNECTOR AND REVISE AS REQ'D. | | | | 8- SPECIFY MULLION SIZE AND ANCHORS FOR | | FIXED WINDOWS AT LIVING ROOM. SIZE OF | | MULLION SHOWN ON PRODUCT APPROVAL | | SUBMITTED DOESN'T RESIST THE DESIGN | | PRESSURES CALCULATED ON PLANS. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 9- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: | | A) SLIDING GLASS DOORS. DADE COUNTY NOA | | AND FLORIDA REPORT DON'T CORRESPOND TO | | EACH OTHER. | | | | B) WINDOW MULLION SIZE AS SPECIFIED ON | | PLANS FOR LIVING ROOM WINDOWS. | | | | C) CASEMENT WINDOWS. NEED THE FLORIDA | | PRODUCT APPROVAL PART. MAKE SURE DADE | | COUNTY NOA MATCHES FLORIDA REPORT AND | | ASSEMBLY SHOWN ON PLANS. | | | | D) ROOF TILE. NEED FLORIDA PRODUCT | | APPROVAL. MAKE SURE REPORT SUBMITTTED IS | | THE SAME ONE SUBMITTED FOR FLORIDA | | PRODUCT APPROVAL. | | | | 10- OWES #206.76 FOR UPDATED VALUATION. | | GUEST ROOM WAS NOT CONSIDERED IN A/C | | AREA DECLARED IN APPLICATION. | | | | 11- SPECIFY COLUMNS AT MASTER BEDROOM | | BAY WINDOW. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. SEE SHEET A1. | | | | 12- DETAIL E/A3: CLARIFY WHY USING 6" | | BOLTS INTO CONCRETE. THERE IS NOT | | CONCRETE TO ATTACH TO. REVISE AS REQ'D. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-01 |
Time |
15:14 |
Rev Time |
0.60 |
Received By |
btrobaug |
Date |
2006-08-01 |
Time |
14:34 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-14 |
Time |
17:16 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-07-14 |
Time |
17:11 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-11 |
Time |
13:05 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-11 |
Time |
12:55 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-09 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-09 |
Time |
16:23 |
Sent To |
P |
|
Notes |
2007-01-09 16:24:05 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-31 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-31 |
Time |
10:27 |
Sent To |
E |
|
Notes |
2006-07-31 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-06 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-06 |
Time |
15:30 |
Sent To |
B |
|
Notes |
2005-10-06 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-01 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-01 |
Time |
14:40 |
Sent To |
B |
|
Notes |
2005-09-01 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-02 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-02 |
Time |
08:32 |
Sent To |
P |
|
Notes |
2005-08-02 00:00:00 | TO "P" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-28 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-28 |
Time |
10:54 |
Sent To |
Z |
|
Notes |
2005-07-28 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-09 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-09 |
Time |
17:39 |
Sent To |
E |
|
Notes |
2005-06-09 00:00:00 | TO RES RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-13 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-31 |
Time |
13:49 |
Sent To |
|
|
Notes |
2005-05-31 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-16 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-16 |
Time |
16:46 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-02-01 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-02-01 |
Time |
13:17 |
Sent To |
|
|
Notes |
2007-02-01 13:18:33 | SANITARY RISER DIAGRAM REVISION OK |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-08-09 |
Time |
07:36 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-08-09 |
Time |
07:36 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-06-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-18 |
Time |
07:56 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-06-18 |
Time |
07:56 |
Sent To |
B |
|
Notes |
2005-06-18 00:00:00 | DENIED; | | VENT REQUIRED BETWEEN W/C AND BIDET. | | MORNING BAR SINK MISSING FROM RISER | | DIAGRAM. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-01 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-01 |
Time |
14:51 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-07-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-13 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-09 |
Time |
15:59 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | DENIED, | | 1. NEED TO MEET THE REQUIRED SIDE | | SETBACK APPROVED FOR DEVELOPMENT. THIS | | LOT IS NOT INCLUDED IN THE APPROVED | | MINOR AMENDMENT FOR ZERO LOT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|