Plan Review Stops For Permit 05051927 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-21 |
Time |
18:30 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-12-21 |
Time |
18:30 |
Sent To |
PC |
|
Notes |
2005-12-21 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- PROVIDE COMPLETE INFORMATION FOR | | SLIDING GLASS DOORS UNDER A SEPARATE | | PERMIT AS AGREED ON PROVISO DATED | | 9-7-05. | | | | 2- OWES $70.00 REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-07 |
Time |
16:31 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
2005-09-07 |
Time |
16:31 |
Sent To |
PC |
|
Notes |
2005-09-07 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- AS AGREED WITH CONTRACTOR, PROVIDE | | COMPLETE INFORMATION FOR SLIDING GLASS | | DOORS (UNDER LOCAL PRODUCT APPROVAL | | PROCESS) UNDER A SEPARATE PERMIT. | | 2- NEED INFO. FOR BBQ HOOD FOR EXTERIOR | | USE AND SPECIFIC GRILL TO BE USED. | | 3- A) SPECIFY CONNECTOR AT THE END OF | | GIRDER TRUSS @ CLUB RM & MASTER BEDRM. | | B) SPECIFY CONNECTOR AT THE END OF | | GIRDER TRUSS ABOVE FOYER. SEE PLANS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-12 |
Time |
15:48 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-08-12 |
Time |
15:48 |
Sent To |
PC |
|
Notes |
2005-08-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-A)PROVIDE COMPLETE SPECS AND LISTING | | FOR BBQ AND HOOD. SEC. 2808 FBC 2001. | | GRILL INFORMATION SUBMITTED IN THE | | INSTALLATION BOOKLET ONLY. NEED | | INFORMATION FOR SPECIFIC MODEL SELECTED | | WITH CORRESPONDING APPROVAL LISTING. | | B) THE HOOD INFORMATION SUBMITTED | | DOESN'T SPECIFY IF IT'S FOR USE INDOOR | | OR OUTDOOR. NEED COMPLETE INFORMATION | | FOR OUTDOOR USE HOOD. | | | | 2- SLIDING GLASS DOORS: A) BUILDING | | OFFICIAL IS IN THE PROCESS OF REVIEWING | | APPLICATION FOR LOCAL PRODUCT APPROVAL. | | CONTACT LUIS MARTINEZ AT 805-6710 FOR | | LOCAL PRODUCT APPROVAL QUESTIONS. | | B) DADE COUNTY NOA REPORT SUBMITTED WITH | | THIS PACKAGE IS MISSING THE DRAWINGS OF | | SLIDING GLASS DOORS THAT ARE ACTUALLY | | GOING TO BE INSTALLED. SEE PLANS AND | | SUBMIT COMPLETE PACKAGE. | | | | 3-A) SPECIFY CONNECTOR AT THE END OF | | GIRDER TRUSS ABOVE CLUB ROOM & MASTER | | BEDROOM. | | B) SPECIFY CONNECTOR AT THE END OF | | GIRDER TRUSS ABOVE FOYER. SEE PLANS. | | | | 4- NEED RECORDED N.O.C. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-07-12 |
Time |
18:21 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-07-12 |
Time |
18:21 |
Sent To |
Z |
|
Notes |
2005-07-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- UPDATE GENERAL NOTES ON SHEET T1. SEE | | CHAPTER 19 AND 35 FOR PROPER STANDARD | | REFERENCE AND EDITION. ALSO, SEE SEC. | | 2405.2 FBC 2001 AND REVISE SAFETY | | GLAZING NOTE AS REQUIRED. | | | | 3- DESIGN PARAMETERS. CLARIFY WHY THE | | MIN. SOIL BEARING PRESSURE IS NA?. | | | | 4- PROVIDE COMPLETE SPECS AND LISTING | | FOR BBQ TO BE INSTALLED IN THE PORCH. | | SEC. 2808 FBC 2001. | | | | 5- REVISE COLUMNS SPECIFIED FOR LANAI. | | THEY ARE C4 COLUMNS, NOT C2. | | | | 6- REVISE /UPDATE ALL TRUSS ANCHORS TO | | MATCH NAIL SIZE AND NUMBER ON REVISED | | CATALOGUE TO COMPLY WITH SEC. 1609.4.3 | | FBC 2001. PROVIDE TESTING AND | | ENGINEERING FOR NAIL SIZE AND NUMBER | | THAT DIFFER FROM THOSE ALREADY TESTED | | AND PUBLISHED BY THE MANUFACTURER. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 7- CONNECTOR THD210 IS A WOOD TO WOOD | | CONNECTOR. SEE CATALOGUE FOR PROPER | | MASONRY CONNECTOR AND REVISE AS REQUIRED | | | | 8- SPECIFY MULLION SIZE AND ANCHORS FOR | | FIXED WINDOWS AT LIVING ROOM. SEE | | PRODUCT APPROVAL TO VERIFY THAT THEY | | RESIST THE CALCULATED DESIGN PRESSURES. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | 9- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: | | A) CASEMENT WINDOWS. NEED FLORIDA | | PRODUCT APPROVAL. | | | | B) SLIDING GLASS DOORS AS SHOWN ON | | PLANS. | | | | C) WINDOW MULLION SIZE AS SPECIFIED ON | | PLANS FOR LIVING ROOM WINDOWS. | | | | 10- REVISE ENERGY CALCULATIONS. NEED | | WORST CASE SCENARIOCALCULATIONS WHEN | | USING IT FOR A MODEL. | | | | 11- CLARIFY WHY USING ONLY AN F | | CONNECTOR FOR END OF GIRDER TRUSS ABOVE | | ENTRY OF BEDROOM #3. SPECIFY CALCULATED | | UPLIFT LOADS. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 12- REAR ELEVATION DON'T MATCH PLANS. | | SEE BREAKFAST AREA AND CABANA BATH. | | REVISE AS REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-11 |
Time |
18:33 |
Rev Time |
0.55 |
Received By |
btrobaug |
Date |
2006-10-11 |
Time |
18:26 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-05 |
Time |
06:38 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2006-10-05 |
Time |
06:16 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-02 |
Time |
12:31 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-05-02 |
Time |
12:04 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-11 |
Time |
12:54 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-11 |
Time |
12:43 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-23 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-23 |
Time |
19:51 |
Sent To |
E |
|
Notes |
2006-09-23 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-21 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-21 |
Time |
08:12 |
Sent To |
E |
|
Notes |
2006-04-21 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-17 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-17 |
Time |
10:59 |
Sent To |
B |
|
Notes |
2005-11-17 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-01 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-01 |
Time |
14:44 |
Sent To |
B |
|
Notes |
2005-09-01 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-28 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-28 |
Time |
16:16 |
Sent To |
P |
|
Notes |
2005-07-28 00:00:00 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-09 |
Time |
17:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-09 |
Time |
17:37 |
Sent To |
E |
|
Notes |
2005-06-09 00:00:00 | TO RES RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-13 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-01 |
Time |
09:39 |
Sent To |
|
|
Notes |
2005-06-01 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-16 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-16 |
Time |
17:04 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-08-09 |
Time |
07:08 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-08-09 |
Time |
07:08 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-06-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-18 |
Time |
07:26 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-06-18 |
Time |
07:26 |
Sent To |
B |
|
Notes |
2005-06-18 00:00:00 | RISER DIAGRAM NOT TO CODE. | | W/M REQUIRESITS OWN DRAIN AND VENT. (ON | | A DIFFERENT WALL) | | BIDETS (2) ARE NOT VENTED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-07-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-13 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-09 |
Time |
16:03 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | ZONING TO REVIEW LAST.NEEDS GRACE | | OPINION REGARDING PERMIT. |
|
|