Plan Review Details - Permit 05051927
Plan Review Stops For Permit 05051927
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-12-21 Cont ID  
Sent By jgomez Date 2005-12-21 Time 18:30 Rev Time 1.00
Received By jgomez Date 2005-12-21 Time 18:30 Sent To PC
Notes
2005-12-21 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE COMPLETE INFORMATION FOR
 SLIDING GLASS DOORS UNDER A SEPARATE
 PERMIT AS AGREED ON PROVISO DATED
 9-7-05.
  
 2- OWES $70.00 REVISION FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-09-07 Cont ID  
Sent By jgomez Date 2005-09-07 Time 16:31 Rev Time 1.50
Received By jgomez Date 2005-09-07 Time 16:31 Sent To PC
Notes
2005-09-07 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1- AS AGREED WITH CONTRACTOR, PROVIDE
 COMPLETE INFORMATION FOR SLIDING GLASS
 DOORS (UNDER LOCAL PRODUCT APPROVAL
 PROCESS) UNDER A SEPARATE PERMIT.
 2- NEED INFO. FOR BBQ HOOD FOR EXTERIOR
 USE AND SPECIFIC GRILL TO BE USED.
 3- A) SPECIFY CONNECTOR AT THE END OF
 GIRDER TRUSS @ CLUB RM & MASTER BEDRM.
 B) SPECIFY CONNECTOR AT THE END OF
 GIRDER TRUSS ABOVE FOYER. SEE PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-08-12 Cont ID  
Sent By jgomez Date 2005-08-12 Time 15:48 Rev Time 2.00
Received By jgomez Date 2005-08-12 Time 15:48 Sent To PC
Notes
2005-08-12 00:00:00BUILDING REVIEW CHECKLIST:
 1-A)PROVIDE COMPLETE SPECS AND LISTING
 FOR BBQ AND HOOD. SEC. 2808 FBC 2001.
 GRILL INFORMATION SUBMITTED IN THE
 INSTALLATION BOOKLET ONLY. NEED
 INFORMATION FOR SPECIFIC MODEL SELECTED
 WITH CORRESPONDING APPROVAL LISTING.
 B) THE HOOD INFORMATION SUBMITTED
 DOESN'T SPECIFY IF IT'S FOR USE INDOOR
 OR OUTDOOR. NEED COMPLETE INFORMATION
 FOR OUTDOOR USE HOOD.
  
 2- SLIDING GLASS DOORS: A) BUILDING
 OFFICIAL IS IN THE PROCESS OF REVIEWING
 APPLICATION FOR LOCAL PRODUCT APPROVAL.
 CONTACT LUIS MARTINEZ AT 805-6710 FOR
 LOCAL PRODUCT APPROVAL QUESTIONS.
 B) DADE COUNTY NOA REPORT SUBMITTED WITH
 THIS PACKAGE IS MISSING THE DRAWINGS OF
 SLIDING GLASS DOORS THAT ARE ACTUALLY
 GOING TO BE INSTALLED. SEE PLANS AND
 SUBMIT COMPLETE PACKAGE.
  
 3-A) SPECIFY CONNECTOR AT THE END OF
 GIRDER TRUSS ABOVE CLUB ROOM & MASTER
 BEDROOM.
 B) SPECIFY CONNECTOR AT THE END OF
 GIRDER TRUSS ABOVE FOYER. SEE PLANS.
  
 4- NEED RECORDED N.O.C.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-07-12 Cont ID  
Sent By jgomez Date 2005-07-12 Time 18:21 Rev Time 2.00
Received By jgomez Date 2005-07-12 Time 18:21 Sent To Z
Notes
2005-07-12 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- UPDATE GENERAL NOTES ON SHEET T1. SEE
 CHAPTER 19 AND 35 FOR PROPER STANDARD
 REFERENCE AND EDITION. ALSO, SEE SEC.
 2405.2 FBC 2001 AND REVISE SAFETY
 GLAZING NOTE AS REQUIRED.
  
 3- DESIGN PARAMETERS. CLARIFY WHY THE
 MIN. SOIL BEARING PRESSURE IS NA?.
  
 4- PROVIDE COMPLETE SPECS AND LISTING
 FOR BBQ TO BE INSTALLED IN THE PORCH.
 SEC. 2808 FBC 2001.
  
 5- REVISE COLUMNS SPECIFIED FOR LANAI.
 THEY ARE C4 COLUMNS, NOT C2.
  
 6- REVISE /UPDATE ALL TRUSS ANCHORS TO
 MATCH NAIL SIZE AND NUMBER ON REVISED
 CATALOGUE TO COMPLY WITH SEC. 1609.4.3
 FBC 2001. PROVIDE TESTING AND
 ENGINEERING FOR NAIL SIZE AND NUMBER
 THAT DIFFER FROM THOSE ALREADY TESTED
 AND PUBLISHED BY THE MANUFACTURER. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 7- CONNECTOR THD210 IS A WOOD TO WOOD
 CONNECTOR. SEE CATALOGUE FOR PROPER
 MASONRY CONNECTOR AND REVISE AS REQUIRED
  
 8- SPECIFY MULLION SIZE AND ANCHORS FOR
 FIXED WINDOWS AT LIVING ROOM. SEE
 PRODUCT APPROVAL TO VERIFY THAT THEY
 RESIST THE CALCULATED DESIGN PRESSURES.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 9- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) CASEMENT WINDOWS. NEED FLORIDA
 PRODUCT APPROVAL.
  
 B) SLIDING GLASS DOORS AS SHOWN ON
 PLANS.
  
 C) WINDOW MULLION SIZE AS SPECIFIED ON
 PLANS FOR LIVING ROOM WINDOWS.
  
 10- REVISE ENERGY CALCULATIONS. NEED
 WORST CASE SCENARIOCALCULATIONS WHEN
 USING IT FOR A MODEL.
  
 11- CLARIFY WHY USING ONLY AN F
 CONNECTOR FOR END OF GIRDER TRUSS ABOVE
 ENTRY OF BEDROOM #3. SPECIFY CALCULATED
 UPLIFT LOADS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 12- REAR ELEVATION DON'T MATCH PLANS.
 SEE BREAKFAST AREA AND CABANA BATH.
 REVISE AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-10-11 Cont ID  
Sent By btrobaug Date 2006-10-11 Time 18:33 Rev Time 0.55
Received By btrobaug Date 2006-10-11 Time 18:26 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-10-05 Cont ID  
Sent By btrobaug Date 2006-10-05 Time 06:38 Rev Time 0.75
Received By btrobaug Date 2006-10-05 Time 06:16 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-02 Cont ID  
Sent By btrobaug Date 2006-05-02 Time 12:31 Rev Time 0.50
Received By btrobaug Date 2006-05-02 Time 12:04 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-06-11 Cont ID  
Sent By btrobaug Date 2005-06-11 Time 12:54 Rev Time 0.50
Received By btrobaug Date 2005-06-11 Time 12:43 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-09-23 Cont ID  
Sent By adarroug Date 2006-09-23 Time 19:51 Rev Time 0.00
Received By adarroug Date 2006-09-23 Time 19:51 Sent To E
Notes
2006-09-23 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-04-21 Cont ID  
Sent By adarroug Date 2006-04-21 Time 08:12 Rev Time 0.00
Received By adarroug Date 2006-04-21 Time 08:12 Sent To E
Notes
2006-04-21 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-11-17 Cont ID  
Sent By adarroug Date 2005-11-17 Time 10:59 Rev Time 0.00
Received By adarroug Date 2005-11-17 Time 10:59 Sent To B
Notes
2005-11-17 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 14:44 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 14:44 Sent To B
Notes
2005-09-01 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 16:16 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 16:16 Sent To P
Notes
2005-07-28 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-06-09 Cont ID  
Sent By shill Date 2005-06-09 Time 17:37 Rev Time 0.00
Received By shill Date 2005-06-09 Time 17:37 Sent To E
Notes
2005-06-09 00:00:00TO RES RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-07-13 Cont ID  
Sent By mmclean Date 2005-07-13 Time 11:43 Rev Time 0.00
Received By mmclean Date 2005-06-01 Time 09:39 Sent To  
Notes
2005-06-01 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-06-16 Cont ID  
Sent By hmoser Date 2005-06-16 Time 17:29 Rev Time 0.00
Received By hmoser Date 2005-06-16 Time 17:04 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-09 Cont ID  
Sent By jleech Date 2005-08-09 Time 07:08 Rev Time 0.33
Received By jleech Date 2005-08-09 Time 07:08 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-06-18 Cont ID  
Sent By jleech Date 2005-06-18 Time 07:26 Rev Time 0.50
Received By jleech Date 2005-06-18 Time 07:26 Sent To B
Notes
2005-06-18 00:00:00RISER DIAGRAM NOT TO CODE.
 W/M REQUIRESITS OWN DRAIN AND VENT. (ON
 A DIFFERENT WALL)
 BIDETS (2) ARE NOT VENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-07-13 Cont ID  
Sent By mmclean Date 2005-07-13 Time 11:43 Rev Time 0.00
Received By mmclean Date 2005-06-09 Time 16:03 Sent To  
Notes
2005-06-09 00:00:00ZONING TO REVIEW LAST.NEEDS GRACE
 OPINION REGARDING PERMIT.