Plan Review Stops For Permit 05051446 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-02-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-02-24 |
Time |
10:58 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2006-02-24 |
Time |
10:57 |
Sent To |
PC |
|
Notes |
2006-02-24 00:00:00 | 2-24-06 REVISION # 4 SWING OF DOOR SUITE | | | | #104.JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-02-22 |
Time |
16:51 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2006-02-22 |
Time |
16:51 |
Sent To |
PC |
|
Notes |
2006-02-22 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05051446 | | ADD: 2247 PALM BEACH LAKES | | CONT: ANDREA CONSTRUCTION | | TEL: (561)358-4797 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | 1) COMMENT# 6 FROM THE PREVIOUS REVIEW, | | SUITE# 104 DOOR BY THE ELEVATOR | | DOESN'T MEET REQUIREMENTS OF: | | 11-4.13.6 MANEUVERING CLEARENCES | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | AT DOORS THAT ARE NOT AUTOMATIC OR | | POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | IN THE REQUIRED CLEARENCES SHALL BE | | CLEAR & LEVEL. | | REQUIRES 18" OF WALL NEXT TO THE | | LATCH PULL SIDE. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
15:29 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2005-12-23 |
Time |
15:29 |
Sent To |
PC |
|
Notes |
2005-12-23 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05051446 | | ADD: 2247 PALM BEACH LAKES | | CONT: ANDREA CONSTRUCTION | | TEL: (561)358-4797 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SINCE THE SCOPE OF WORK HAS CHANGED | | UPDATE THE VALUE OF THE WORK TO BE | | COMPLETED UNDER THIS PERMIT. | | | | 2) EXTERIOR AWNING IS TO BE COVERED | | UNDER A SEPERATE PERMIT. | | 104.1.1 WPB ADMINISTRATIVE CODE. | | | | 3) PLANS DO NOT INDICATE THE MINIMUM | | BUILDING TYPE?601.2.1 | | IF BUILDING IS FIRE SPRINKLERED? IF | | SUPERVISED? TABLE 600 | | | | 4) SHEETS A1-A2 BOTH SHOW AN EXIT ACCESS | | CORRIDOR BUT DOESN'T PROVIDE A UL | | LISTING OR GYPSUM LISTING FOR THE WALL | | ASSEMBLY OR FIRE RESISTANCE | | RATING?704.2.4. | | | | 5)TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | 6) SUITE# 104 DOOR BY THE ELEVATOR | | DOESN'T MEET REQUIREMENTS OF: | | 11-4.13.6 MANEUVERING CLEARENCES | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | AT DOORS THAT ARE NOT AUTOMATIC OR | | POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | IN THE REQUIRED CLEARENCES SHALL BE | | CLEAR & LEVEL. | | REQUIRES 18" OF WALL NEXT TO THE | | LATCH PULL SIDE. | | | | 7) SCOPE OF WORK REVEALS THAT WINDOWS | | ARE TO BE REPLACED: | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | 1606.1.4(1) IN WIND BORNE DEBRIS | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | ASSUMED TO BE OPENINGS UNLESS SUCH | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | WITH AN IMPACT RESISTANT COVERING MEET- | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | LARGE MISSLE TEST. | | FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | REPLACEMENT WINDOWS . | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-06-21 |
Time |
08:33 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2005-06-21 |
Time |
08:33 |
Sent To |
|
|
Notes |
2005-06-21 00:00:00 | BUILDING PROVISOS: | | | | 1)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 2)705.7.1 JOINTS INSTALLED IN OR BE- | | TWEEN FIRE RESISTANT WALLS, FIRE RESIS- | | TANT FLOORS OR FLOOR/ CEILING ASSEMBLIES | | AND FIRE RESISTANT ROOFS OR ROOF/ CEIL- | | ING ASSEMBLIES SHALL BE PROTECTED BY AN | | APPROVED FIRE RESISTANT JOINT SYSTEM | | DESIGNED TO RESIST THE PASSAGE OF FIRE | | FOR A PERIOD NOT LESS THAN THE RE- | | QUIRED FIRE RESISTANCE RATING OF THE | | WALL, FLOOR OR FLOOR IN OR BETWEEN | | WHICH IT IS INSTALLED. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-22 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-22 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
20:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-08 |
Time |
20:27 |
Sent To |
|
|
Notes |
2006-02-08 00:00:00 | ******* UNSAT ********** | | | | 1)NOTE: PLEASE SEE SOME NOTES FROM | | PREVIOUS REVIEW WHICH NEED TO BE | | ADDRESSED. | | | | | | | | | | 1)NOTE: OK | | | | 2)NOTE: OK | | | | 3)NOTE:? THIS IS UNCLEAR, AS LIGHTING | | LOADS ON "AM" SCHEDULE DO NOT SEEM TO | | CORRELATE WITH CALCS SHOWN ONE-1 | | | | **PLEASE SEE THAT ALL CONTINUOUS | | LOADS ARE SHOWN ON LOAD CALCULATIONS | | INCLUDING ANY LARGEST MOTOR LOADS AT | | 125%. | | 215.3,230.42 ETC. | | PLEASE SEE ONLY EXT LTS SEEM TO BE SHOWN | | AT 125%. | | | | 4)NOTE: NO, ? SEE NOTE ABOVE AS, THE | | LOADS ON "AM" SHOULD BE THE SAME AS | | SHOWN FOR MAIN BLDG SERVICE? | | PLEASE VERIFY WHY THIS IS SHOWN | | SUBSTANTIALLY LARGER. | | | | **PLEASE CORRLELATE LOADS SHOWN ON | | MSB "AM" WITH RISER | | CALCULATIONS/LOAD(S). | | 215.5 | | | | 5)NOTE: OK | | | | ** PLEASE CALL TO GO OVER COMMENTS AS | | SHEETS FOR INTERIOR WALLS ETC MAY BE | | STAMPED IF NEEDED FOR INSPECTIONS ONCE | | FIRE REVIEW IS DONE AND PASSED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATEIN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER' | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-20 |
Time |
19:31 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-20 |
Time |
19:22 |
Sent To |
|
|
Notes |
2005-12-20 00:00:00 | ***UNSAT *** | | | | 1)NOTE: PLEASE SEE DUE TO MAJOR INCREASE | | IN SCOPE OF WORK FROM ORIGINAL PERMIT | | APPLICATION AND PLANS SUBMITTED, PLEASE | | ADJUST VALUE FOR COMPLETE SCOPE OF WORK. | | 104.6.5 FBC, ADMINISTRATIVE CODE | | AMENDMENTS. | | | | 2)NOTE: PLEASE SEE MECHANICAL REVIEW | | COMMENTS SND POSSIBLE FIRE REVIEW | | COMMENTS WHICH WILL AFFECT ELECTRICAL | | PLANS. | | | | 3)NOTE: PLEASE SEE THAT ALL CONTINUOUS | | LOADS ARE SHOWN ON LOAD CALCULATIONS | | INCLUDING ANY LARGEST MOTOR LOADS AT | | 125%. | | 215.3,230.42 ETC. | | PLEASE SEE ONLY EXT LTS SEEM TO BE SHOWN | | AT 125%. | | | | 4)NOTE: PLEASE CORRLELATE LOADS SHOWN ON | | MSB "AM" WITH RISER | | CALCULATIONS/LOAD(S). | | 215.5 | | | | 5)NOTE: PLEASE VERIFY OF THE 1200 MCB IS | | BACKFED INTO PANEL. THIS APPEARS TO BE | | SHOWN ON THE PANEL SCHEDULE AS WELL AS | | BEING INDICATED ON THE TOP OF THE PANEL | | AS A MCB PANEL.?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATEIN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER' | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-17 |
Time |
09:00 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2005-06-17 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2006-02-15 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-02-15 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-02-15 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-12-22 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-12-22 |
Time |
10:10 |
Sent To |
|
|
Notes |
2005-12-22 00:00:00 | ******DENIED****** | | | | 1) PLEASE PROVIDE FIRE RESISTANCE | | INFORMATION FOR NEW AWNINGS. | | | | 2) PLANS MENTION DUCT SMOKE DETECTORS. | | DEVICES WHERE INSTALLED SHALL INITIATE A | | GENERAL FIRE ALARM IN ACCORDANCE WITH | | LOCAL REQUIREMENTS, AND IF TIED INTO A | | FIRE ALARM SYSTEM. | | | | 3) ADDITIONAL EXIT SIGNS REQUIRED IN | | CORRIDORS TO SARTISFY MINIMUM 100' | | DISTANCE REQUIREMENT. | | | | 4) IF APPLICABLE, SEPARATE SHOP DRAWINGS | | AND PERMITS REQUIRED FOR FIRE SPRINKLER | | AND FIRE ALARM SYSTEMS. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-06-17 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-06-17 |
Time |
10:27 |
Sent To |
|
|
Notes |
2005-06-17 00:00:00 | ****PASSED**** | | | | 1) SEPARATE SHOP DRAWINGS AND PERMITS | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM REMODEL. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 805-6722 OR 835-2951 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
08:33 |
Sent To |
M |
|
Notes |
2006-01-27 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-01-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-12 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-12 |
Time |
11:32 |
Sent To |
|
|
Notes |
2006-02-06 00:00:00 | TO "COMM" BD#27 | 2006-01-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-14 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-14 |
Time |
12:51 |
Sent To |
|
|
Notes |
2005-11-22 00:00:00 | TO "COMM" BD#61 | 2005-11-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-19 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-19 |
Time |
10:32 |
Sent To |
M |
|
Notes |
2005-07-19 00:00:00 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-14 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-14 |
Time |
14:01 |
Sent To |
|
|
Notes |
2005-07-19 00:00:00 | TO "COMM" BD#21 | 2005-07-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-01 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-05-25 |
Time |
09:55 |
Sent To |
|
|
Notes |
2005-06-06 00:00:00 | TO COMM BD#19 | 2005-05-25 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2006-02-06 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2006-02-06 |
Time |
16:55 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-01-30 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-01-30 |
Time |
08:03 |
Sent To |
|
|
Notes |
2006-01-30 00:00:00 | PULLED MECHANICAL PLANS OUT FILED ONE | | CALLED CONTRACTOR TO P/U OTHER.HM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2005-12-03 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2005-12-03 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2005-12-02 |
Time |
19:32 |
Sent To |
|
|
Notes |
2005-12-03 00:00:00 | ------------------DENIED---------------- | | | | 1) DUCT SIZES, GRILL DESIGNATION AND CFM | | MISSING IN SUITES 104 THRU 110 AND 204 | | THRU 208. PLEASE INCLUDE ALL NECESSARY | | INFORMATION ON PLAN. | | | | 2) KEY NOTES 5,6,7 ON PAGES M2 AND M3 | | REFER TO DETAIL 1/M7 FOR DUCT/DIFFUSER | | SIZES AND LAYOUT. THIS DETAIL CONTAINS | | NO SUCH INFORMATION. | | | | 3) KEY NOTES 5,6,7 ON PAGES M4 AND M5 | | REFER TO DETAIL 1/M8 FOR DUCT/DIFFUSER | | SIZES AND LAYOUT. THIS DETAIL CONTAINS | | NO SUCH INFORMATION. | | | | 4) VAV T1-14 ON PAGE M2 REFERENCES KEY | | NOTE 4 (FIRE DAMPER EXCEPTION). DUCT IS | | NOT SHOWN TO RUN THE MIN. 5' PAST THE | | RATED WALL TO MEET THE CONDITIONS OF THE | | FIRE DAMPER EXCEPTION. | | | | 5) PAGE M5 SUITE 209 SHOWS A 24X18 DUCT | | FEEDING VAV T2-20 AND T2-21 EXCLUSIVELY. | | THE TWO VAVS COMBINED CALL FOR A TOTAL | | OF 270 CFM. IS THIS INTENTIONAL? | | | | 6) GENERAL HVAC NOTE #9 CALLS FOR DUCT | | SMOKE DETECTORS IN ALL 4 AC SYSTEMS | | BASED ON CFMS.PLEASE INDICATE ON PLAN | | THE LOCATION OF DUCT SMOKE DETECTORS, | | ENSURING SERVICE/INSPECTION ACCESS AND | | COMPLIANCE WITH MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | RONALD J REGUEIRO AT 561.805.6734 OR | | PATTY KRAUS AT 561.805.6719 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-07-22 |
Time |
07:47 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-07-22 |
Time |
07:47 |
Sent To |
B |
|
Notes |
2005-07-22 00:00:00 | MECH. PLAN RESUB 5/20/05 | | | | ALL SIX CHECK LIST ITEMS, O/K. | | | | PAT RAFTER 561/805/6728. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-01 |
Time |
07:35 |
Rev Time |
1.20 |
Received By |
pkrauss |
Date |
2005-07-01 |
Time |
07:35 |
Sent To |
|
|
Notes |
2005-07-01 00:00:00 | DENIED: | | 1.PLAN SHEET M-4, SUPPLY AND RETURN | | AIR DUCT PENETRATING TENANT SEPARATION | | BETWEEN SUITE 206 & 205, FIRE DAMPERS | | ARE NOT INDICATED ON THE PLAN. | | | | 2.PROVIDE DETAIL OF THE SHAFT ENCLOSER | | INDICATED ON PLAN SHEET M-5.PLEASE | | NOTE, FIRE DAMPER REQUIRED WHERE DUCT | | PENETRATES THE SHAFT WALL 2001 FBC | | 705.1.2.2.1. | | | | 3.PLEASE INDICATE PROTECTION FOR DUCT | | DUCTS SERVING THE FIRST FLOOR. 2001 | | FBC(M) 607.4. | | | | 4.PLAN SHEET M-7 KEY NOTE #3 | | REFERENCES DUCT PENETRATION DETAIL | | 7/S-1.PLEASE CLARIFY LOCATION OF THE | | DETAIL? | | | | 5.PROVIDE TIE DOWN & SUPPORT DETAIL | | FOR RTU CURB SHOWN ON PLAN SHEET M-8. | | | | 6.PLEASE NOTE, ENGINEER IS REQUIRED TO | | HAVE IS PRINTED NAME & LICENSE NUMBER | | INDICATED ON EACH PLAN SHEET IN | | ACCORDANCE WITH FS 471.025 & FAC | | 61G15-23.002.CERTIFICATE OF | | AUTHORIZATION (BUSINESS NUMBER) SHALL | | ALSO BE IDENTIFIED ON THE TITLE BLOCK. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-02-23 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-02-23 |
Time |
14:00 |
Sent To |
|
|
Notes |
2006-02-23 00:00:00 | PLUMBING PLAN REVIEW EXAMINER | | PAUL SCHMITZ 561-805-6692 | | [email protected] | | FBC PLUMBING 2004 | | FBC FUEL GAS 2004 | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | CH 1, ADMINISTRATION, 2004 EDITION ( | | ATFBC)FBC BUILDING 2004, CH 11 | | | | PLUMBING COMMENTS NOT INCLUDED 2-16-06 | | | | 2-22-06 MISSING COMMENTS E-MAILED, | | BYROBERT SCHULLER. | | EXISTING REST RM'S NO CHANGES. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-02-16 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-02-16 |
Time |
15:10 |
Sent To |
|
|
Notes |
2006-02-16 00:00:00 | PAUL SCHMITZ | | FBC2001 FUEL GAS CODEPLAN REVIEW | | FBC 2001 PLUMBING CODEPLAN REVIEW | | FBC 2001 FL ACESSIBILITY CODE PLAN | | REVIEW | | "DENIED" | | "PREVIOUS COMMENTS NOT ADDRESSED" | | | | DENIED | | 1.) SHT A-1,A-2 | | ?104.2 DRAWINGS AND SPECIFICATIONS | | ?104.2.1 REQUIREMENTS. AS REQUIRED BY | | ?104.3.1.1 OF THE CODE, TWO OR | | MORE COPIES OF SPECIFICATIONS, AND OF | | DRAWINGS DRAWN TO SCALE WITH | | SUFFICIENT CLARITY AND DETAIL TO | | INDICATE THE NATURE AND CHARACTER OF THE | | WORK, SHALL ACCOMPANY THE APPLICATION | | FOR A PERMIT.SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR | | SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR | | SPECIFIC INFORMATION.ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS | | AND | | ACCOMPANYING DATA SHALL BEAR THE NAME | | AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | 2.) | | SECTION 11-4 | | ACCESSIBLE ELEMENTS AND | | SPACES:SCOPE AND TECHNICAL REQUIREMENTS | | ?11-4.1 MINIMUM REQUIREMENTS. | | ?11-4.1.1 APPLICATION. | | ?11-4.1.1(1) GENERAL. THIS CODE | | ESTABLISHES THE MINIMUM STANDARDS FOR | | THE ACCESSIBILITY OF BUILDINGS AND | | FACILITIES BUILT OR ALTERED WITHIN | | THE STATE. | | ?11-4.1.1(1)(A) ALL AREAS OF NEWLY | | DESIGNED OR NEWLY CONSTRUCTED | | BUILDINGS AND FACILITIES REQUIRED | | TO BE ACCESSIBLE BY ?11-4.1.2 AND | | ?11-4.1.3 AND ALTERED PORTIONS OF | | EXISTING BUILDINGS AND FACILITIES | | REQUIRED TO BE ACCESSIBLE BY | | ?11-4.1.6 SHALL COMPLY WITH THIS CODE, | | ?11-4.1 THROUGH ?11-4.35, UNLESS | | OTHERWISE PROVIDED IN THIS | | SECTION OR AS MODIFIED IN A | | SPECIAL APPLICATION SECTION. | | 3.) SHT P-1 | | A)PROVIDE A DWV AND WATER PIPE | | ISOMETRIC.SEC 104.2 | | B) WATER HEATER DETAIL | | ?P607.3 THERMAL EXPANSION CONTROL. A | | MEANS OF CONTROLLING INCREASED | | PRESSURE CAUSED BY THERMAL EXPANSION | | SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH ?P607.3.1 AND ?P607.3.2. | | | | END OF COMMENTS, QUESTIONS | | 561-805-6692 | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-12-17 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-12-17 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-12-17 |
Time |
10:52 |
Sent To |
|
|
Notes |
2005-12-17 00:00:00 | 0 PAUL SCHMITZ | | FBC2001 FUEL GAS CODEPLAN REVIEW | | FBC 2001 PLUMBING CODEPLAN REVIEW | | FBC 2001 FL ACESSIBILITY CODE PLAN | | REVIEW | | DENIED | | 1.) SHT A-1,A-2 | | ?104.2 DRAWINGS AND SPECIFICATIONS | | ?104.2.1 REQUIREMENTS. AS REQUIRED BY | | ?104.3.1.1 OF THE CODE, TWO OR | | MORE COPIES OF SPECIFICATIONS, AND OF | | DRAWINGS DRAWN TO SCALE WITH | | SUFFICIENT CLARITY AND DETAIL TO | | INDICATE THE NATURE AND CHARACTER OF THE | | WORK, SHALL ACCOMPANY THE APPLICATION | | FOR A PERMIT.SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR | | SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR | | SPECIFIC INFORMATION.ALL | | INFORMATION, DRAWINGS, SPECIFICATIONS | | AND | | ACCOMPANYING DATA SHALL BEAR THE NAME | | AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN. | | 2.) | | SECTION 11-4 | | ACCESSIBLE ELEMENTS AND | | SPACES:SCOPE AND TECHNICAL REQUIREMENTS | | ?11-4.1 MINIMUM REQUIREMENTS. | | ?11-4.1.1 APPLICATION. | | ?11-4.1.1(1) GENERAL. THIS CODE | | ESTABLISHES THE MINIMUM STANDARDS FOR | | THE ACCESSIBILITY OF BUILDINGS AND | | FACILITIES BUILT OR ALTERED WITHIN | | THE STATE. | | ?11-4.1.1(1)(A) ALL AREAS OF NEWLY | | DESIGNED OR NEWLY CONSTRUCTED | | BUILDINGS AND FACILITIES REQUIRED | | TO BE ACCESSIBLE BY ?11-4.1.2 AND | | ?11-4.1.3 AND ALTERED PORTIONS OF | | EXISTING BUILDINGS AND FACILITIES | | REQUIRED TO BE ACCESSIBLE BY | | ?11-4.1.6 SHALL COMPLY WITH THIS CODE, | | ?11-4.1 THROUGH ?11-4.35, UNLESS | | OTHERWISE PROVIDED IN THIS | | SECTION OR AS MODIFIED IN A | | SPECIAL APPLICATION SECTION. | | 3.) SHT P-1 | | A)PROVIDE A DWV AND WATER PIPE | | ISOMETRIC.SEC 104.2 | | B) WATER HEATER DETAIL | | ?P607.3 THERMAL EXPANSION CONTROL. A | | MEANS OF CONTROLLING INCREASED | | PRESSURE CAUSED BY THERMAL EXPANSION | | SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH ?P607.3.1 AND ?P607.3.2. | | | | END OF COMMENTS, QUESTIONS | | 561-805-6692 | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-24 |
Time |
18:15 |
Rev Time |
0.86 |
Received By |
kstevens |
Date |
2005-06-24 |
Time |
18:15 |
Sent To |
|
|
Notes |
2005-06-24 00:00:00 | NO PLUMBING RISERS SUBMITTED. MINOR | | CHANGES IN DWV. PER CITY CODES SUBJECT | | TO FIELD INSPECTORS APPROVAL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-06-29 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-29 |
Time |
16:11 |
Sent To |
|
|
Notes |
2005-06-29 00:00:00 | PARKING MUST BE DOUBLE STRIPPED. |
|
|