Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-09-21 Cont ID  
Sent By mjacobs Date 2007-09-21 Time 07:45 Rev Time 0.00
Received By mjacobs Date 2007-09-21 Time 07:26 Sent To E
Notes
2007-09-21 07:45:49SENT TO BT DESK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-08 Cont ID  
Sent By mjacobs Date 2007-08-08 Time 14:29 Rev Time 0.00
Received By mjacobs Date 2007-08-08 Time 13:32 Sent To E
Notes
2007-08-08 14:29:46BUILDING PLAN REVIEW
 PERMIT: 05051421
 ADD: 614 37TH STREET
 CONT: BROOKS CONST.
 TEL: (561)236-2473
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW : RE-STAMP
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)THE DRAWING SUBMITTED FOR THE RE-STAMP, IS MISSING
 THE GUTTER/DOWNSPOUTS DETAILS. THE RIGH/LEFT ELEVATION
 IS ALSO MISSING THE TYPICAL 6"X10" HOLES FOR THE
 SECONDARY DRAINAGE. SEE SHEET 2 OF 2.
  
 3)THE DATE THE ENGINEER SIGNED THE APPROVED SET OF
 DRAWINGS WAS 7/22/05. HOW IS IT THAT THE SET SUBMITTED
 FOR RE-STAMP IS DATED 8/23/04. CLARIFY. FLORIDA
 STATUTES 481.221(2)THE SIGNATURE/DATE AND SEAL SHALL
 BE EVIDENCE OF THE AUTHENTICITY OF THAT TO WHICH THEY
 ARE AFFIXED.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-04 Cont ID  
Sent By mjacobs Date 2005-08-04 Time 09:45 Rev Time 2.30
Received By mjacobs Date 2005-08-04 Time 07:28 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-06-22 Cont ID  
Sent By mjacobs Date 2005-06-22 Time 09:53 Rev Time 3.00
Received By mjacobs Date 2005-06-22 Time 06:40 Sent To PC
Notes
2005-06-22 00:00:001) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
 PLEASE SUPPLY A CERTIFIED COPY OF THE
 NOC. THE NOC PROVIDED HAS BEEN ALTERED
 AND THE DESCRIPTION OF THE NOC IS FOR A
 SINGLE FAMILY HOME. THE APPLICATION
 DESCRIPTION STATES NEW DETATCHED
 GARAGE,THEREFORE THE SCOPE OF WORK ON
 THE NOC DOES NOT CORRESPOND WITH THE
 APPLICATION.
  
 2) THE BOTTOM OF FOUNDATIONS SHALL
 EXTEND NO LESS THAN 12 INCHES BELOW
 FINISH GRADE, FBC SEC. 1804.1.3
  
 3) FOR TYPE VI BUILDING 12' FROM THE
 ASUME PROPERTY LINE, TABLE 600 ALLOWS
 ONLY 40% OF UNPROTECTED OPENINGS.
  
 4) SHOW IN DETAIL HOW DRAINAGE WILL BE
 ACHIEVED FROM ROOF. PLEASE SHOW PRIMARY
 AND SECONDARY DRAINAGE.
  
 5) THE GARAGE DOOR SHOWS A DIMENTION OF
 18'7",HOWEVER, ACCORDING TO YOUR
 DIMENTIONS THE OPENING FOR THE GARAGE
 DOOR IS ONLY 16'. PLEASE CLARIFY.
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-09-24 Cont ID  
Sent By btrobaug Date 2007-09-24 Time 13:44 Rev Time 0.00
Received By btrobaug Date 2007-09-24 Time 13:44 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-08-03 Cont ID  
Sent By btrobaug Date 2005-08-03 Time 17:20 Rev Time 0.50
Received By btrobaug Date 2005-08-03 Time 16:46 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-06-07 Cont ID  
Sent By btrobaug Date 2005-06-07 Time 18:05 Rev Time 0.50
Received By btrobaug Date 2005-06-07 Time 17:32 Sent To B
Notes
2005-06-07 00:00:00 
 THE FIRMS CERTIFICATE OF AUTHORIZATION
 NUMBER MUST BE IN THE TITLE BLOCK. SEE
 FAC 61G15-23.002.
  
 SEE 225.31 AND250.32 FOR ELECTRICAL
 REQUIREMENTS AT SEPERATE STRUCTURES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 16:38 Rev Time 0.00
Received By adarroug Date 2007-09-17 Time 16:38 Sent To B
Notes
2007-09-17 16:39:08TO "MJACOBS" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-06 Cont ID  
Sent By adarroug Date 2007-08-06 Time 11:41 Rev Time 0.00
Received By adarroug Date 2007-08-06 Time 11:41 Sent To B
Notes
2007-08-06 11:41:50TO "MJACOBS" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-03 Cont ID  
Sent By adarroug Date 2005-08-03 Time 08:54 Rev Time 0.00
Received By adarroug Date 2005-08-03 Time 08:54 Sent To E
Notes
2005-08-03 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 16:07 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 08:54 Sent To Z
Notes
2005-07-28 00:00:00TO "Z" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-31 Cont ID  
Sent By adarroug Date 2005-05-31 Time 08:53 Rev Time 0.00
Received By adarroug Date 2005-05-31 Time 08:53 Sent To E
Notes
2005-05-31 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-06-22 Cont ID  
Sent By mjacobs Date 2005-06-22 Time 16:11 Rev Time 0.00
Received By mjacobs Date 2005-05-20 Time 10:20 Sent To  
Notes
2005-05-20 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2005-08-02 Cont ID  
Sent By mmclean Date 2005-08-02 Time 17:26 Rev Time 0.00
Received By mmclean Date 2005-08-02 Time 17:25 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-05-27 Cont ID  
Sent By mmclean Date 2005-05-27 Time 11:34 Rev Time 0.00
Received By mmclean Date 2005-05-27 Time 11:34 Sent To I
Notes
2005-05-27 00:00:00DENIED,
 1. NEED TO PROVIDE AN UPDATED SURVEY
 SHOWING THE EXISTING STRUCTURE AND THE
 NEW GARAGE WITH SETBACKS.
 2. SITEPLAN IS NOT SUFFICENT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720