Plan Review Stops For Permit 05051421 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-09-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-09-21 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-09-21 |
Time |
07:26 |
Sent To |
E |
|
Notes |
2007-09-21 07:45:49 | SENT TO BT DESK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-08 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-08 |
Time |
13:32 |
Sent To |
E |
|
Notes |
2007-08-08 14:29:46 | BUILDING PLAN REVIEW | | PERMIT: 05051421 | | ADD: 614 37TH STREET | | CONT: BROOKS CONST. | | TEL: (561)236-2473 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW : RE-STAMP | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)THE DRAWING SUBMITTED FOR THE RE-STAMP, IS MISSING | | THE GUTTER/DOWNSPOUTS DETAILS. THE RIGH/LEFT ELEVATION | | IS ALSO MISSING THE TYPICAL 6"X10" HOLES FOR THE | | SECONDARY DRAINAGE. SEE SHEET 2 OF 2. | | | | 3)THE DATE THE ENGINEER SIGNED THE APPROVED SET OF | | DRAWINGS WAS 7/22/05. HOW IS IT THAT THE SET SUBMITTED | | FOR RE-STAMP IS DATED 8/23/04. CLARIFY. FLORIDA | | STATUTES 481.221(2)THE SIGNATURE/DATE AND SEAL SHALL | | BE EVIDENCE OF THE AUTHENTICITY OF THAT TO WHICH THEY | | ARE AFFIXED. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-08-04 |
Time |
09:45 |
Rev Time |
2.30 |
Received By |
mjacobs |
Date |
2005-08-04 |
Time |
07:28 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-22 |
Time |
09:53 |
Rev Time |
3.00 |
Received By |
mjacobs |
Date |
2005-06-22 |
Time |
06:40 |
Sent To |
PC |
|
Notes |
2005-06-22 00:00:00 | 1) 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | PLEASE SUPPLY A CERTIFIED COPY OF THE | | NOC. THE NOC PROVIDED HAS BEEN ALTERED | | AND THE DESCRIPTION OF THE NOC IS FOR A | | SINGLE FAMILY HOME. THE APPLICATION | | DESCRIPTION STATES NEW DETATCHED | | GARAGE,THEREFORE THE SCOPE OF WORK ON | | THE NOC DOES NOT CORRESPOND WITH THE | | APPLICATION. | | | | 2) THE BOTTOM OF FOUNDATIONS SHALL | | EXTEND NO LESS THAN 12 INCHES BELOW | | FINISH GRADE, FBC SEC. 1804.1.3 | | | | 3) FOR TYPE VI BUILDING 12' FROM THE | | ASUME PROPERTY LINE, TABLE 600 ALLOWS | | ONLY 40% OF UNPROTECTED OPENINGS. | | | | 4) SHOW IN DETAIL HOW DRAINAGE WILL BE | | ACHIEVED FROM ROOF. PLEASE SHOW PRIMARY | | AND SECONDARY DRAINAGE. | | | | 5) THE GARAGE DOOR SHOWS A DIMENTION OF | | 18'7",HOWEVER, ACCORDING TO YOUR | | DIMENTIONS THE OPENING FOR THE GARAGE | | DOOR IS ONLY 16'. PLEASE CLARIFY. | | | | BUILDING PLAN REVIEW | | MYRON JACOBS | | TEL: (561)805-6726 | | FAX: (561)659-8026 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-09-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-24 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-24 |
Time |
13:44 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-08-03 |
Time |
17:20 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-08-03 |
Time |
16:46 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-07 |
Time |
18:05 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-07 |
Time |
17:32 |
Sent To |
B |
|
Notes |
2005-06-07 00:00:00 | | | THE FIRMS CERTIFICATE OF AUTHORIZATION | | NUMBER MUST BE IN THE TITLE BLOCK. SEE | | FAC 61G15-23.002. | | | | SEE 225.31 AND250.32 FOR ELECTRICAL | | REQUIREMENTS AT SEPERATE STRUCTURES. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-17 |
Time |
16:38 |
Sent To |
B |
|
Notes |
2007-09-17 16:39:08 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-06 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-06 |
Time |
11:41 |
Sent To |
B |
|
Notes |
2007-08-06 11:41:50 | TO "MJACOBS" DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-03 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-03 |
Time |
08:54 |
Sent To |
E |
|
Notes |
2005-08-03 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-28 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-28 |
Time |
08:54 |
Sent To |
Z |
|
Notes |
2005-07-28 00:00:00 | TO "Z" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-05-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-31 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-31 |
Time |
08:53 |
Sent To |
E |
|
Notes |
2005-05-31 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-22 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-05-20 |
Time |
10:20 |
Sent To |
|
|
Notes |
2005-05-20 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-02 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-02 |
Time |
17:25 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-05-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-05-27 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-27 |
Time |
11:34 |
Sent To |
I |
|
Notes |
2005-05-27 00:00:00 | DENIED, | | 1. NEED TO PROVIDE AN UPDATED SURVEY | | SHOWING THE EXISTING STRUCTURE AND THE | | NEW GARAGE WITH SETBACKS. | | 2. SITEPLAN IS NOT SUFFICENT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|