Plan Review Stops For Permit 05051108 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-03-27 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-03-27 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-03-14 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-03-14 |
Time |
13:05 |
Sent To |
|
|
Notes |
2007-03-14 13:20:58 | | | REVISION #4 COMMENTS | | ------------------------------------ | | | | | | | | DRAWINGS SUBMITTED SHALL BE SIGNED AND SEALED BY | | DESIGNER OF RECORD. | | | | PROVIDE TYPICAL WALL SECTION. | | | | SHOW COMPLIANCE FOR THE EMERGENCY ESCAPE REQUIREMENT, | | SEE FBC, R310.1, FROM NEW SLEEPING ROOM UPSTAIRS. | | | | | | | | | | | | | | L.MARTINEZ | | 805-6710 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-23 |
Time |
07:51 |
Rev Time |
0.75 |
Received By |
alange |
Date |
2006-02-17 |
Time |
11:14 |
Sent To |
|
|
Notes |
2006-02-23 00:00:00 | HURRICANE ROOM STRUCTURAL DETAIL OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-10-03 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-10-03 |
Time |
09:55 |
Rev Time |
1.66 |
Received By |
alange |
Date |
2005-10-03 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-09-08 |
Time |
08:58 |
Rev Time |
2.00 |
Received By |
alange |
Date |
2005-09-08 |
Time |
07:19 |
Sent To |
|
|
Notes |
2005-09-08 00:00:00 | DENIED | | | | 1. 713.13(2) F.S.THE NOTICE OF | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | THE DESCRIBED IMPROVEMENT OR | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | DAYS OF RECORDING. | | | | 2.ALL MIAMI-DADE PRODUCT APPROVALS | | SUBMITTED REQUIRE THE FOLLOWING STATE | | PRODUCT APPROVAL TO BE ATTACHED. | | ROOFING, GARAGE OVERHEAD DOOR AND | | WINDOWS. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 7.ROOF SHEATHING NAILING SHALL COMPLY | | WITH FBC 2306.1 WPB AMMENDMENTS | | SHOW PERIMETER ZONES AT 4" FASTENER | | SPACING. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-06-17 |
Time |
14:10 |
Rev Time |
4.00 |
Received By |
alange |
Date |
2005-06-16 |
Time |
15:21 |
Sent To |
|
|
Notes |
2005-06-17 00:00:00 | DENIED | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 2.ALL PRODUCT APPROVALS SUBMITTED | | REQUIRE THE FOLLOWING TO BE ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 3.SUBMIT DETAILS FOR FIREPLACE. | | | | 4.PRODUCT APPROVALS FOR EXTERIOR DOOR | | AN OUTSWING DOOR.PLANS SHOW DOOR AS AN | | INSWING DOOR.PLEASE REVISE. | | | | 5.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | FOR LINTELS WITH STATE APPROVAL. | | | | 6.BUILDING IS IN FLOOD ZONE "A". | | PLEASE NOTE ON PLAN THAT THE FINISH | | FLOOR ELEVATION SHALL BE A MINIMUM OF 6" | | ABOVE THE BASE FLOOD ELEVATION OF 7FT. | | | | 7.ROOF SHEATHING NAILING SHALL COMPLY | | WITH FBC 2306.1 WPB AMMENDMENTS | | | | 8.SOILS REPORTS SUBMITTED NOT | | ORIGIONAL SIGNED AND SEALED.PLEASE | | SUBMIT ORIGONALS. | | | | 9.BUILDING IS TO BE IN AN AREA OF | | QUESTIONABLE SOILS. | | PLEASE SUBMIT A REVISED SUBSURFACE | | EXPLORATION REPORT AS RECOMMENDED BY | | ARDAMAN & ASSOCIATES REPORT FROM | | DECEMBER 13, 04.INCLUDE | | RECOMMENDATIONS FOR FOOTINGS AND | | FOUNDATION WORK. | | | | 10.ON WINDOW SCHEDULE SHOW TYPE OF | | WINDOW USED. | | | | 11.SHOW SIZE AND LOCATION OF ATTIC | | ACCESS COMPLYING WITH FBC 2309.6 | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
P |
Date |
2007-04-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-14 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-14 |
Time |
08:11 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-03 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-03 |
Time |
11:02 |
Sent To |
PC |
|
Notes |
2007-04-03 12:35:52 | ** UNSAT** | | | | *** PROVISO/REVISION NEEDED**** | | | | | | 1) NOTE: PLEASE SEE THE LOAD FOR THE AMOUNT OF RECESSED | | LIGHTING FIXTURES SHALL BE BASED ON THE FIXTURE WATTAGE | | BY THE NUMBER OF FIXTURES ON TOP OF THE 3WATTS PER SQ | | FT. | | THIS WAS TAKEN TO CODE PANELIST LAST YEAR TO CONFIRM | | THE SECTION OF 220.3B4. WHEN THE AMOUNT OF RECESSED | | LIGHTING IS FAR BEYOND WHAT WOULD BE NORMALLY | | CONSIDERED FOR THE GENERAL LIGHTING LOAD, THEN THE | | WATTAGE FOR FIXTURES ARE TO BE ADDED. | | THERE WAS NO CUT OFF FOR THE AMOUNT OF FIXTURES, AS IT | | WAS LEFT TO THE AHJ TO DETERMINE LOADS ON AN INDIVIDUAL | | BASIS WHEN REVIEWING THE AMOUNT OF FIXTURES. | | PLEASE SEE IN EITHER CASE THE LIGHTING IS NOT DE-RATED | | AT 50%. THERE IS NO LOCATION IN THE CODE WHERE LIGHTING | | LOADS PERMIT THIS DE-RATING FOR RESIDENTIAL USE. | | PLEASE SEE 220.30, 220.31. | | | | 2) NOTE: PLEASE SEE 250.66, 310.15B6 FOR THE MINIMUM | | GROUNDING ELECTRODE CONDUCTOR. | | | | 3) NOTE: PLEASE SEE 110.26 AS THE CU PANEL IS STILL | | BEING SHOWN BEHIND THE CONDENSING UNIT. | | PLEASE SEE THIS WAS REDLINED ON PLANS. | | | | ** PLANS WERE GIVEN A *PROVISO* UPON ISSUANCE TO HAVE | | ALL REVISIONS AND CORRECTIONS MADE BEFORE ROUGH AND | | THIS WAS NOT DONE. THE SERVICE AND SEVERAL OTHER | | CHANGES WERE MADE TO THE PLANS WITHOUT REVISIONS EVER | | BEING SUBMITTED. | | PLEASE KNOW THAT THE REVISED PLANS ARE TO BE 100%, | | SUBMITTED AND STAMPED FOR REVIEW BEFORE FINAL | | ELECTRICAL INSPECTION. | | PLANS WHICH ARE BEING STAMPED AT THIS TIME ARE ONLY FOR | | A PARTIAL FINAL OR TCO. | | PLEASE SUBMIT REVISED PLANS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-29 |
Time |
15:25 |
Sent To |
PC |
|
Notes |
2007-03-29 20:53:37 | | | | | ****** UNSAT ***** | | | | ** PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1 | | IN THE PLAN REVIEW COMMENTS CAN BE FOUND IN THE | | ADMINISTRATIVE SECTION OF THE 2004 FBC AS ADOPTED BY | | THE CITY OF WEST PALM BEACH. | | | | | | ** PLEASE SEE THE PLANS SUBMITTED ARE NOW MORE COMPLETE | | PLANS FOR REVIEW FOR CODE COMPLIANCE. PLEASE SEE THERE | | ARE NEW COMMENTS BASED ON THE PLANS SUBMITTED. | | THE PREVIOUS REVIEW REQUESTED PLANS TO BE COMPLETED FOR | | CODE COMPLIANCE. | | | | 1) NOTE: PLEASE SEE ALL CIRCUITING HAS NOW BEEN REMOVED | | FROM PLANS. PLEASE SEE BY DOING SO SOME ITEMS DO NOT | | INDICATE HOW THEY ARE BEING CONTROLLED. | | PLEASE SEE OUTSIDE FLOODS? | | HOW ARE THESE CONTROLLED? | | FBC 106.1.2 | | | | 2) NOTE: PLEASE SEE PANEL SCHEDULE IS NOT SHOWING ANY | | WIRE SIZES TO BE REVIEWED FOR CODE COMPLIANCE. 240.4, | | 310.16, 408.4 | | FBC 106.3.5.4. | | | | 3) NOTE: PLEASE CLARIFY THE SMOKE DEVICES AS SOME WHICH | | ARE BEING SHOWN AS SD ARE NOTED AS SMOKE DETECTORS AND | | SOME WITH THE S SYMBOLS ARE ALSO NOTED AS SMOKE | | DETECTORS? | | PLEASE SEE NFPA-72 DEFINITIONS FOR TYPES OF DEVICES. IF | | SMOKE ALARMS, INDICATE AS SA. | | PLEASE SEE THE PANEL SCHEDULE SHOWS THE 120VA HARDWIRED | | DEVICES AS SMOKE DETECTORS, WHICH IS NOT POSSIBLE. | | PLEASE SEE NOTE ON PANEL SCHEDULE WHICH ALSO MENTIONS | | SMOKE DETECTORS?? | | IF THERE ARE MULTIPLE TYPES OF DEVICES INSTALLED, | | PLEASE CLARIFY AND ALSO INDICATE IF TIED INTO A FA OR | | SECURITY SYSTEM W/ SOUNDING DEVICES. IF SD IS USED, | | THEN SOUNDING DEVICES ARE REQUIRED TO ALERT AN OCCUPANT | | IN THE EVENT OF ALARM STATUS. | | NFPA-72 2002 11.5.1.1.1, 11.8.3 | | | | 4) NOTE: PLEASE CORRELATE THE RISER WITH THE PANELS. | | PLEASE SEE PANEL *A* IS BEING SHOWN AS A 400A RATED | | PANEL WITH A 350AMP MAIN WHEN THE PANEL ON RISER IS | | SHOWN AS 200AMPS?? | | PLEASE KNOW THAT DEPENDING ON WHICH IS ACTUALLY | | INSTALLED; THE RISER MAY NEED TO BE COMPLETELY REVISED | | TO INCREASE SERVICE, CONDUCTORS GROUNDING ETC. 215.5, | | 310.16, 240.4 ETC. | | FBC 106.3.5.4 | | | | 5) NOTE: PLEASE SEE 310.15B6, 250.66 AS THE SERVICE IS | | BEING SHOWN AS 400AMPS, OR MORE DEPENDING ON NOTE #4 | | ABOVE. MINIMUM SIZE GEC IS 1/0. | | | | 6) NOTE: PLEASE SEE MISSING SMOKE ALARMS, OR SMOKE | | DETECTORS IN BEDROOMS ON 2ND FLOOR. BED-RM #4, AND | | OFFICE WHICH IS CONSIDERED AN ADAPTABLE SLEEPING ROOM. | | NFPA-72 11.5.1.1.1 | | | | 7) NOTE: PLEASE SEE THE VALUE FOR THE LOW VOLTAGE | | PERMIT AS PREVIOUSLY NOTED AHS NOT BEEN INCREASED BY | | THE CONTRACTOR. PLEASE KNOW THAT A VALUE WILL BE | | ASSESSED BY THIS OFFICE USING THE MARSHALL'S AND SWIFT | | GUIDE WHICH IS ADOPTED INTO THE FBC PER 108.3 | | | | 8) NOTE: PLEASE SEE 220.3B4 AS THE RECESSED LIGHTING AS | | REDLINED ON NOTES ON PREVIOUS PLANS NEEDS TO BE SHOWN | | IN LOAD CALCULATIONS. | | | | 9) NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTACLES SERVING | | KITCHEN COUNTERSPACES ARE TO BE SHOWN AS GFI OR GFI | | PROTECTED. | | | | ** PLEASE KNOW AS THE PLANS ARE NOT COMPLETE WITH SOME | | INFORMATION AS NEEDED FOR REVIEW, ONLY A REVIEW OF | | SUBMITTED PLANS COULD BE DONE. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-08 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-08 |
Time |
14:25 |
Sent To |
PC |
|
Notes |
2007-03-08 15:45:33 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE THE PLANS SUBMITTED ARE NOT | | COMPLETE AT THIS TIME FOR COMPLETE REVIEW OF CODE | | COMPLIANCE. | | PLEASE KNOW THAT THERE MAY BE COMMENTS ONCE PLANS ARE | | COMPLETE. | | | | 2) NOTE: PLEASE SEE *PROVISO* WHICH WAS GIVEN IN | | SEPTEMBER OF 05 WHICH REQUIRED THOSE ITEMS TO BE | | REVISED *BEFORE ROUGH*. THIS WAS NOT DONE YET ROUGH | | ELECTRICAL INSPECTION WAS CALLED IN WITH NOTES ATTACHED | | TO PLANS. | | INSPECTOR INFORMED THIS OFFICE THAT THE NOTES WHICH | | WERE ATTACHED TO PLANS WERE TORN OFF. | | PLEASE COMPLETE THE FOLLOWING. | | | | PLEASE COMPLETE ALL CIRCUITING ON PLANS AND CORRELATE | | WITH REVISED PANEL SCHEDULES TO BE REVISED AND | | SUBMITTED. PLEASE SEE MANY ITEMS ON PLANS DO NOT | | CONTAIN CIRCUITING AND REVIEW FOR CODE COMPLIANCE CAN | | NOT BE DONE AT THIS TIME. | | PLEASE COMPLETE AND SUBMIT LOAD CALCULATIONS PER NEC. | | PLEASE CORRELATE LOADS ON PANEL SCHEDULES AND COMPLETE | | AS REQUIRED PER CODE AND PREVIOUS *PROVISO *NOTES. | | PLEASE SUBMIT THE COMPLETE ELECTRICAL RISER DIAGRAM TO | | BE REVIEWED FOR CODE COMPLIANCE. | | PLEASE BE SURE TO SEE THE 2002 NEC. | | 210.52,210.11, 220, 310.16, 240.4 ETC | | FBC 106.1.2, 106.3.5.4 ETC. | | | | 3) NOTE: PLEASE SEE THE DEVICES WHICH ARE SHOWN AS | | SMOKE DETECTORS SHOULD BE SHOWN AS SMOKE ALARMS IF THEY | | ARE 120V WITH DETECTION AND SOUNDING IN THE SINGLE | | UNIT. | | PLEASE SEE NFPA-72 DEFINITIONS FOR THE DIFFERENCES FROM | | SMOKE DETECTORS AND SMOKE ALARMS. | | | | 4) NOTE: PLEASE SEE THERE ARE NOW NUMEROUS LOW VOLTAGE | | ITEMS ON PLANS WHICH THE LOW VOLTAGE PERMIT WAS UNDER | | VALUED BASED ON PLANS. | | PLEASE HAVE THE CONTRACTOR INCREASE VALUE FOR ALL LV | | WORK AS SHOWN WHICH SHALL INCLUDE ALL LABOR AND | | MATERIALS EVEN IF OWNER SUPPLIED. | | PLEASE KNOW A VALUE MAY BE ACCESSED BY THIS OFFICE IF | | AN APPROPRIATE VALUE IS NOT APPLIED.** | | FBC 108.3 | | | | ** PLEASE KNOW A HOLD IS NOW BEING PLACED ON THE | | ELECTRICAL AND BUILDING PERMIT ON INSPECTIONS. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-15 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-15 |
Time |
15:44 |
Sent To |
B |
|
Notes |
2006-02-15 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE "PROVISO" NOTES FROM | | 9/29/05 WHICH HAVE NOT BEEN ADDRESSED OR | | SUBMITTED. | | PLEASE SEE THE PERMIT WAS ISSUED ON THE | | CONDITION THESE ITMES BE ADDRESSED, CODE | | COMPLIANT AND RETURNED FOR REVIEW. | | PLEASE SEE NOTES BELOEW. | | | | 2)NOTE: PLEASE CORRELATE ALL PANELS, | | LOADS ETC. | | PLEASE SUBMIT LOADS CALCUALTIONS WHICH | | MEET THE NEC 220 | | PLEASE CORRELATE LOADS ON PANELS ETC. | | PLEASE RE-FIGURE AS REQUESTED ON | | PREVIOUS REVIEW. | | 215.5 | | | | 3)NOTE: PLEASE SEE MANY ITEMS FOR | | PREVIOUS "PROVISO" CAN BE REVIEWED FOR | | CORRECTED ITEMS AS THE FIRST FLR PLANS | | WERE NOT SUBMITTED.? | | 215.5 | | | | 4)NOTE: PLEASE SEE RISER HAS NOW BEEN | | REVISED TO REMOVED GROUNDING ELECTODE | | ATTACHMENT TO FOOTER STEEL, HOWEVER THIS | | ATTACHMENT FOR NEW CONSTRUCTION IS | | REQUIRED TO BE INSTALLED PER 250.50, | | 250.52A | | THIS SHALL NOT BE DELETED FROM PLANS AND | | RISER. | | | | 5)NOTE: PLEASE SEE A NEW DETAIL WAS | | SUBMITTED FOR A "HURRICANE ROOM" HOWEVER | | PLANS WERE NOT REVISED TO SHOW THIS | | ROOM, LTS, RECEPTS ETC. 210.52,210.70 | | ETC. | | PLEASE ALSO SEE BLDG COMMENTS AS THE | | 8 1/2X 11 IS MISSING THE TITLE BLOCK FOR | | ARCHITECT AND OTHER POSSIBLE INFORMATION | | NEEDED FOR BLDG REVIEW. | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | AND OTHER INFORMATION FOR REVIEW. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-09-29 |
Time |
13:20 |
Sent To |
M |
|
Notes |
2005-09-29 00:00:00 | ********** PROVISO/ REVISION ********** | | | | PLEASE SEE ITEMS BELOW ALONG WITH ANY | | OTHER REVISIONS MUST BE SUBMITTED FOR | | REVIEW AND STAMPING BEFORE ANY ROUGH | | ELECTRICAL INSPECTION. | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW STILL NEED TO BE ADDRESSED. | | | | 1)NOTE: PLEASE SEE SMOKE DETECTORS ARE | | REQUIRED ON EACH LEVEL OF A MULTI-LEVEL | | DWELLING LEADING TO THE FLOOR ABOVE IN | | THE IMEDIATE VICINITY OF STAIRS. | | PLEASE SEE MISSING SD AT REAR FOYER | | LOWER LEVEL. | | PLEASE SEE SD AT FRONT FOYER REQUIRED ON | | WALL NO MORE THAN 10' ABOVE FF. | | | | 2)NOTE: PLEASE SEE MIN CONTROL AND | | EGRESS LIGHT FIXTURE(S) REQUIRED AT REAR | | FOYER ENTRY/ EXIT. | | PLEASE ALSO SEE MEANS OF EGRESS FROM | | LAUNDRY RM AND BEDRM #3.3-WAY/4-WAY | | SWITCHES REQUIRED. | | PLEASE SEE SEE A "GAS FIXURE" MAY BE | | INSTALLED ALSO, HOWEVER AN ELECTRICAL SW | | AND FIXTURE IS REQUIRED. | | PLEASE SEE FRONT PORCH IS OK, DUE TO | | ELECTRICAL RECESSED LTS ALONG W/GAS FIX. | | 210.70, LS 101 7.8 | | | | 3)NOTE: PLEASE SEE MISSING RECEPTS PER | | 210.52 | | | | 4)NOTE: PLEASE SEE "DEN" RECEPTS (A-32) | | CIRCUITED TO SMALL APPL CIRCUIT. | | BRKFST AREA, DINING AREA MAY NOT FEED | | OTHER ARES. | | PLEASE ADJUST. | | | | 5)NOTE: PLEASE CORRELATE ALL LOADS ON | | PANELS AND LOAD CALCUALTIONS. | | PLEASE GO THROUGH LOAD CALCULATIONS AND | | RE-FIGURE TO MEET NEC 220. | | PANEL "A" SHOWS 30KVA FOR PANEL "B", | | HOWEVER PANEL "B" SHOWS 40KVA. | | SEE PANEL "C" ETC. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-31 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-08-31 |
Time |
12:23 |
Sent To |
|
|
Notes |
2005-08-31 00:00:00 | *********UNSAT 2ND REVIEW ****** | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | REVIEW AND SOME NEW COMMENTS DUE TO | | CHANGES IN PLANS. | | | | 1)NOTE; 210.8A6,INDICATE GFI'S ALONG | | KITCHEN COUNTERSPACES, REDLINED ONE. | | SEE PLANS. | | | | 2)NOTE: PLEASE SEE NFPA-72, 8-1.4.2, | | WHICH REQUIRES SD'S TO BE MIN OF 3' FROM | | BATH DRS. | | PLEASE SEE REDLINED PLANS FOR THESE. | | PLEASE SEE "GREAT RMM" APPEARS TO SHOW | | TWO SD'S ?? | | THIS IS OK, BUT NOT REQUIRED.(FYI). | | | | 3)NOTE: PLEASE SHOW ALL SERVICE | | EQUIPMENT ON PLANS CORRELATE WITH RISER | | DIAGRAM SUBMITTED. | | PLEASE SEE PLANS DO NOT SHOW LOCATION OF | | METER/SERVICE. | | PLEASE SEE TRANSFER SWITCH IS STILL | | SHOWN ON PLANS, HOWEVER THIS HAS NOW | | BEEN REMOVED FROM RISER? | | | | 4)NOTE:PLEASE SEE CIRCUITING FOR MIN | | DINING RM, ETC RECEPTS WERE REVISED, | | HOWEVER, PLEASE SEE CIRCUIT A-32 WHICH | | SHARES BRKFAST AREA AND DEN AREA. | | PLEASE SEE 210.52B1, OTHER OUTLETS MAY | | NOT BE ON THESE CIRCUITS. | | PLEASE SEE REDLINED RECEPTS ON PLANS IN | | DEN. | | | | 5)NOTE: : PLEASE SEE REDLINED PLANS FOR | | SOME RECEPTS MISSING FOR 2' OF WALL | | SPACE AND WITH 6' OF DOORWAY. . | | 210.52.2ND FLR. | | | | 6)NOTE:PLEASE CORRELATE LOAD | | CALCUALTIONS NOW SUBMITTED. PLEASE SEE | | THE LOADS SEEM TO HAVE BEEN ROUNDED DOWN | | FOR EACH AND SERVICE. PLEASE SEE LOADS | | MAY BE ROUNDED UP , BUT CAN BE ROUNDED | | DOWN. | | PLEASE SEE REDLINED PLANS. | | PLEASE SEE POOL PANEL INDICATES 3.4KW | | AND PANEL "B" SHOWS 4.2? | | PLEASE SEE PANEL "A" SHOWS KW RATING FOR | | PANEL "B" AS 15KW, HOWEVER PANEL "B" | | INDICATES LOAD AT 39.9 WHICH DOES NOT | | SEEM TO CORRELATE WITH LOAD CALCS OR | | PANEL "A"? | | PLEASE SEE 220.31. | | | | 7)NOTE: PLEASE SEE FS 553.80(2)(B), THIS | | IS ONLY A NOTICE. | | | | PLEASE BE SURE TO SEE ANY COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | PLANS. (ZONING ETC) | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS FROM | | SETS AND ONLY INSERT NEW REVISED SHEETS | | INTO COMPLETE SETS FOR REVIEW AND | | STAMPING. | | ONE COPY OF ALL OLD/VOIDED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | | | PLEASE SEE ALL OTHER COMMENTS FOR | | GENERATOR WILL NOT BE INCLUDED. | | PLEASE BE SURE TO SEE COMMENTS DUE TO | | PLANNING FOR LOCATION OF FUTURE | | EQUIPMNET. MAINS AND DISCONNECTING MEANS | | SHALL BE GROUPED. | | 230.72, 225.34, 225.31 | | PLEASE CALL IF THERE ARE ANY QUESTIONS, | | ON THIS. | | | | PLEASE SUBMIT THE ABVOE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CAONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-07 |
Time |
10:58 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2005-06-07 |
Time |
10:58 |
Sent To |
M |
|
Notes |
2005-06-07 00:00:00 | ********** UNSAT ************ | | | | 1)NOTE: PLEASE SEE PERMIT APPLICATION | | MENTIONS "APPROACH AND DRIVEWAY FOR NEW | | TWO STORY HOUSE" PLEASE ADJUST PERMIT | | APPLICATION FOR NEW TWO STORY HOUSE. | | | | 2)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210.8A-6 | | PLEASE SEE AREA(S) TO BE INCLUDED AS | | KITCHEN COUNTERSPACE AREA. | | | | 3)NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | UNIT. | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | TO FLOORS ABOVE AND IN THE VICINITY OF | | BEDROOMS. | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | A MIN OF 3' FROM BATHROOM DOORS AND | | KITCHENS. | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4.1.6.2 | | 8-1.4.2 | | | | 4)NOTE: PLEASE SEE MIN CLEARENCE | | REQUIRED FOR A/C DISC'S. 110.26 | | | | 5)NOTE: PLEASE SHOW ALL SERVICE | | EQUIPMENT ON PLANS. IF GENERATOR IS TO | | BE INCLUDED UNDER ELECTRICAL PERMIT FOR | | MAIN HOUSE. SITE PLAN, SURVEY ETC MUST | | SHOW LOCATION OF GEN. ALSO. | | PLEASE ALSO SEE OTHER COMMENTS FOR GEN | | TO FOLLOW. | | | | 6)NOTE: PLEASE PROVIDE ROMM DESIGNATION | | ON PLANS. | | 215.5 | | | | 7)NOTE: PLEASE SEE CIRCUITING OF DINING | | RM, BREAKFAST AREAS AND THE LIKE PER | | 210.52-B-1. | | | | 8)NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | PLEASE SEE 210.12 2002NEC. | | | | 9)NOTE: PLEASE SEE ROOM ABOVE GARAGE. | | PLEASE SEE RECEPTS WHICH APPEAR TO BE | | FLOOR RECEPTS?? OR ARE THESE | | MIS-LOCATED.? 210.52 | | PLEASE ALSO SEE OTHER MISSING RECEPTS | | MISSING FOR 2' OF WALL SPACE. | | | | 10)NOTE: PLEASE SEE CIRCUITING FOR BATH | | GFI RECEPTS IN MASTER BATH. | | PLEASE SEE 210.11C3, 210.52D | | PLEASE SEE THERE SHALL BE NO OTHER | | RECEPTS/OUTLETS EXCEPT FOR THOSE IN | | BATHRM. | | | | 11)NOTE: PLEASE SEE PLANS INDICATE "SPA" | | RECEPT FOR MASTER BATH. | | PLEASE SEE PANEL SCHEDULE DOES NOT | | INDICATE THIS. PLEASE ALSO ADJUST LOAD | | CALCULATIONS TO INCLUDE LOAD AND PLEASE | | SHOW AS GFI /GFI PROTECTED . | | 215.5,220.31,680.71 | | | | 12)NOTE: PLEASE SUBMIT COMPLETE LOAD | | CALCULATIONS FOR EACH PANEL. | | PLEASE CORRELATE LOADS ON PANEL | | SCHEDULES AND SERVICE RISER LOAD CALCS. | | PLEASE CORRELATE LOAD(S) FOR SUB | | PANEL(S). PLEASE SEE PANEL "A" SHOWS THE | | SAME LOAD AS SUB PANEL "B" , YET LOADS | | IMPOSED ON EACH PANEL(BY PANEL SCHEDULE) | | ARE COMPLETELY DIFFERENT. | | 220,215.5 ETC. | | PLEASE ALSO INCLUDE SIZE OF METERCAN TO | | BE PROVIDED. | | | | 13)NOTE: PLEASE SEE SUB PANEL FOR POOL | | IS MISSING FROM RISER, PANEL SCHEDULES | | ETC.215.5 | | | | 14)NOTE: PLEASE CORRELATE DESCRIPTION | | FOR PANEL "B". PLEASE SEE PANEL SHOWN AS | | 42 CIR, HOWEVER PANEL MENTIONS 30?? | | 215.5 | | | | 15)NOTE: PLEASE SEE 250.50 WHICH | | REQUIRES THE "FOOTER STEEL" TO BE PART | | OF THE GROUNDING ELECTRODE SYSTEM. | | PLEASE SEE RISER MENTIONS STRUCTUAL | | STEEL. IF THE CONSTRUCTION OF THE HOUSE | | ALSO INCLUDES "STRUCTUAL STEEL" THEN IT | | WOULD ALSO BE INCLUDED AS PART IF THE | | GES. 250.50 | | | | PLEASE SEE THE FOLLOWING COMMENTS FOR | | GEN/ATS ETC. | | "IF" GENERATOR IS TO BE INCLUDED AS PART | | OF THESE PLANS AND UNDER THE ELECTRICAL | | PERMIT FOR THE HOUSE, THEN ALL OF THE | | FOLLOWING INFORMATION MUST BE INCLUDED | | WITH THIS PERMIT APPLICATION PACKAGE. | | | | | | 16)NOTE: PLEASE SUBMIT COMLPETE SITE | | PLAN SHOWING GEN LOCATIONS ALONG WITH | | ANY OTHER EQUIPMENT WHICH MAY NEED TO BE | | INCLUDED. THIS MUST ALSO BE INCLUDED ON | | SURVEY SHOWING ALL DIMENIONS. | | FUEL STORAGE TANK? ETC. | | PLEASE ALSO SUBMIT ELEVATIONS FOR | | EQUIPMENT WHICH MUST MUST BE ABOVE BASE | | FLOOD ELEVATION. | | 700.9 AND FEMA REGULATIONS OF UTILITY | | EQUIPMENT. | | | | 17)NOTE: PLEASE INDICATE THE PRIME MOVER | | FOR GEN. | | 215.5,700.12B1-2 ETC | | | | 18)NOTE: PLEASE SEE STRUCTURAL DETAIL9S0 | | MUST BE SUBMITTED FOR BLDG REVIEW FOR | | ATTACHMENT OF GEN TO SLAB/ FBC 140MPH | | WIND LOAD. | | | | 19)NOTE: PLEASE NOTE/KEEP IN MIND MIN | | CLEARENCE FROM WINDOW/DOOR AND ATTIC | | OPENINGS. A MIN OF 10" IS REQUIRED FOR | | EXHAUST. SEE MECH CODE FOR MIN | | REQUIREMENTS. THIS IS NOT AN ELECTRICAL | | CODE. | | | | 20)NOTE: PLEASE SUBMIT COMPLETE | | MANUFACTTURE CUT/SPEC SHEETS FOR | | GENERATOR, AND ATS. | | PLEASE BE SURE ALL MEET 702.3-702.6. | | 225.31-225.36 | | | | 21)NOTE: PLEASE SEE MEANS OF DISC MUST | | MEET 225.31-225.36. | | NO DISC IS SHOWN ON LINE SIDE OF ATS. | | NO INFORMATION FOR ATS IS PROVIDED. | | SIZE? | | PLEASE SEE THE MEANS OF DISC IS REQUIRED | | TO BE LOCATED ADJACENT TO OR BACK TO | | BACK WITH TRANSFER SWITCH. | | 215.5 | | | | 22)NOTE: PLEASE CORRELATE PLANS WITH | | RISER DIAGRAM. PLEASE SEE PLANS MENTIOSN | | AN ATS (AUTOMATIC TRANSFER SWITCH) YET | | RISER MENTIONS A MANUAL TRANSFER | | SWITCH(MTS). | | PLEASE SEE 702.5, IF SYSTEM IS GOING TO | | BE AN "AUTOMATIC" SYSTEM, THEN GEN. IS | | REQUIRED TO BE SIZED FOR SERVICE/LOAD | | CALCULATIONS AS SHOWN. | | MEANS OF LOAD SHEEDING (IF) PROVIDED | | WOULD NEED TO BE SHOWN IN DETAIL. | | 215.5 | | | | 23)NOTE: PLEASE INCLUDE CONDUCTORS FROM | | TRANSFER SWITCH TO MCB PANEL. | | PLEASE SEE 250.24, 250.6 IF FIRST MEANS | | OF DISC IS PROVIDED. | | | | 24)NOTE: PLEASE BE SURE TO NOTE WHEATHER | | OR NOT GEN IS TO BE SEPARATELY DERIVED | | OR NOT.. | | | | PLEASE SEE MANY OF THE ABOVE LOCATIONS | | HAVE BEEN REDLIND ON ONE SET OF PLANS | | FOR COMMENTS ABOVE. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | PLEASE SUBMIT "ONE" SET OF OLD/VOIDED | | SHEETS FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-12 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-12 |
Time |
16:21 |
Sent To |
E |
|
Notes |
2007-04-12 16:21:46 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-30 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-30 |
Time |
17:31 |
Sent To |
E |
|
Notes |
2007-03-30 17:31:52 | TO DEWEY PALMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2007-03-26 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-03-26 |
Time |
18:31 |
Sent To |
|
|
Notes |
2007-03-26 18:31:30 | SENT TO LUIS MATINEZ'S DESK MMILLER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2007-03-26 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-03-26 |
Time |
18:25 |
Sent To |
|
|
Notes |
2007-03-26 18:25:30 | SENT TO DEWEY PALMER'S DESK MMILLER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-26 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-26 |
Time |
18:21 |
Sent To |
Z |
|
Notes |
2007-03-26 18:21:46 | TO JOHN ROACH |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-13 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-13 |
Time |
14:53 |
Sent To |
Z |
|
Notes |
2007-03-13 14:53:39 | TO "Z" BOX--DRIVEWAY REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
14:20 |
Sent To |
E |
|
Notes |
2007-03-06 14:21:53 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-02 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-02 |
Time |
14:49 |
Sent To |
B |
|
Notes |
2007-02-02 14:49:51 | TO "LMARTINEZ" DESK/2 REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-13 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-13 |
Time |
17:27 |
Sent To |
E |
|
Notes |
2006-02-13 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-09-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-29 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-28 |
Time |
09:22 |
Sent To |
E |
|
Notes |
2005-09-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-23 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-23 |
Time |
10:28 |
Sent To |
Z |
|
Notes |
2005-09-23 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-29 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-29 |
Time |
11:21 |
Sent To |
E |
|
Notes |
2005-08-29 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-15 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-15 |
Time |
13:52 |
Sent To |
Z |
|
Notes |
2005-08-15 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-06-17 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-06-06 |
Time |
13:36 |
Sent To |
|
|
Notes |
2005-06-06 00:00:00 | TO SFD RACK (E) |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-01 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-01 |
Time |
14:59 |
Sent To |
B |
|
Notes |
2005-06-01 00:00:00 | TO "MISC" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-24 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-24 |
Time |
14:22 |
Sent To |
ENG |
|
Notes |
2005-05-24 00:00:00 | TO "ENG" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-16 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-16 |
Time |
16:02 |
Sent To |
Z |
|
Notes |
2005-05-16 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-30 |
Time |
08:10 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-09-30 |
Time |
08:10 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2005-09-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-09-07 |
Time |
08:23 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2005-09-07 |
Time |
08:23 |
Sent To |
B |
|
Notes |
2005-09-07 00:00:00 | *** DENIED *** | | 1) PLEASE SHOW WHICH SUB-SECTION OF | | SECTION 703 FBC/M 2001 YOU ARE USING | | TO OBTAIN COMBUSTION AIR FOR THE | | LAUNDRY ROOM. | | 2) SUPPLY AIR DUCTS (MAIN TRUNK LINES & | | BRANCH LINES) ARE NOT PROPERLY SIZED | | FOR ADEQUATE AIR DISRIBUTION. | | 3) RETURN AIR DUCTS TO AHU'S ARE NOT | | PROPERLY SIZED PER 2001 FBC/M 601.4. | | 4) RETURN AIR GRILLS TO AHU'S ARE NOT | | SIZED (18"X18" WOULD BE TO SMALL). | | 5) SUPPLY AIR DUCTS CAN NOT GO TO | | CLOSETS IN GARAGE (HAZARDOUS FUMES | | MAY ENTER DUCTS WHEN UNIT IS NOT | | RUNNING). | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-06-15 |
Time |
09:14 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2005-06-15 |
Time |
07:29 |
Sent To |
P |
|
Notes |
2005-06-15 00:00:00 | DENIED: | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | FOR REVIEW; | | 1.PLAN SHEET P2.1 INDICATES A GAS FIRE | | PLACE.PLEASE PROVIDE MANUFACTURER'S | | SUBMITTAL DATA.PROVIDE COMBUSTION AIR | | CALUCALTIONS AND MAKE-UP AIR (IF | | REQUIRED). | | | | 2.PLAN SHEET P2.2 INDICATES A GAS | | DRYER.PLEASE PROVIDE CALCUALTIONS FOR | | COMBUSTION AIR AND AIR MAKE UP PER | | CHAPER 7 OF THE 2001 FBC(M). | | | | 3.PLANS DO NOT INDICATE ACCESS OR | | HANGING DETAIL FOR THE AHU'S 1 & 2. | | SHOW COMPLAINCE WITH 2001 FBC CHAPTER 13 | | SUB-CHAPTER 610.1.ABC.3.5. | | | | 4.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 | | FBC(M)307.2.3.NOTE ON PLAN SHEET M2.1 | | INDICATES THE REQUIREMENT FOR THE PAN | | BUT ONLY MENTIONS CONDENSATE LINE. | | SECONDARY DRAIN LINE SHALL TERMINATE AT | | A CONSPICUOUS POINT. | | | | 5.CONDENSATE SHALL TERMINATE A MINIMUM | | OF 12" AWAY FROM THE BUILDING STRUCTURE | | PER 2001 FBC 1503.4.4. | | | | 6.INDICATE LINE SIZE FOR THE | | CONDESATE, AND REFRIGERANT LINES. | | | | 7.CONDENSING UNITS BE SUPPORTED BY A | | LEVEL CONCRETE SLAB A MINIMUM OF 3 1/2 | | THICKEXTENDING A MINIMUM OF 2" ABOVE | | THE ADJOINING GRADE. | | | | 8.PLANS DO NOT INDICATE TIE DOWN OR | | ANCHORING FOR THE CONDENSING UNIT. | | PLEASE REFERENCE 2001 FBC(M)301.13.1. | | | | 9.PROVIDE GRILLE SIZES.ALSO MISSING | | RETURN AIR DUCT & JUMPER SIZES.PLEASE | | NOTE,SQUARE INCHES OF THE RETURN AIR | | JUMPERS ARE TO BE A MINIMUM OF 1 1/2 | | TIMES GREATER THAN THE SUPPLY AIR INTO | | THAT SPACE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-08-31 |
Time |
14:28 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-08-31 |
Time |
14:28 |
Sent To |
M |
|
Notes |
2005-08-31 00:00:00 | PROVISO; | | PLUMBING ONLY SEPARATE PERMIT AND PLANS | | REQUIRED FOR GAS. | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-15 |
Time |
17:20 |
Rev Time |
1.20 |
Received By |
kstevens |
Date |
2005-06-15 |
Time |
17:20 |
Sent To |
B |
|
Notes |
2005-06-15 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 1 | | | | 1. SHT P2.2 THE SANITARY RISER DIAGRAM | | DOES NOT MEET CODE REQUIREMENTS. CORRECT | | THE FOLLOWING. | | A. VENT REQUIRED AT LAV FIRST FLOOR | | POWDER ROOM . SECTION 901.2.1 | | B. CLEANOUT IS REQUIRED AT THE BASE OF | | THE STACK TO THE SECOND FLOOR. SECTION | | 708.3.4. | | C. SIZE ALL PIPE SECTIONS PER TABLE | | 710.1(1). | | D. VENTS ARE REQUIRED FOR BOTH KITCHEN | | SINKS. SECTION 901.2.1. | | E. VENTS REQUIRED FOR LAV NEAR THE | | GARAGE AND THE SINK IN THE GARAGE. | | SECTION 901.2.1. | | F. GARAGE SINK SHALL NOT DRAIN THROUGH | | THE HORIZONTAL WET VENT OF THE POWDER | | ROOM FIXTURES. SECTION 909.1. SINK SHALL | | DISCHARGE DOWNSTREAM OF FIXTURES. | | G. VENT REQUIRED FOR THE SECOND FLOOR | | DOUBLE LAVS. SECTION 104.2.1. | | H. W/C AND TUB ARE NOT VENTED AS PIPED | | FOR BATHROOM WITH THE DOUBLE LAVS, AND | | THE WASH MACHINE SHALL NOT DRAIN THROUGH | | THE HORIZONTAL WET VENT OF THAT | | BATHROOM. SECTIONS 901.2.1. & 909.1. | | I. VENTS ARE REQUIRED FOR THE TUB AND | | SINK NEAR AND AT THE GREAT ROOM. SECTION | | 901.2.1. | | J. THE GREAT ROOM SINK SHALL NOT DRAIN | | THRU THE HORIZONTAL WET VENT OF THE | | BATHROOM FIXTURES. THIS SINK SHALL | | DISCHARGE DOWNSTREAM OF THE BATHROOM | | FIXTURES. SECTION 909.1 | | K. A VENT, A STANDPIPE AND A CLEANOUT | | ARE REQUIRED FOR THE WASH MACHINE. THE | | CLEANOUT SHALL BE LOCATED 4' ABOVE THE | | FLOOR. SECTIONS 708.10, 901.2.1 AND | | 1002.1. | | L. VENTS ARE REQUIRED FOR BOTH LAVS IN | | THE MASTER BATHROOM. SECTION 901.2.1. | | M. FITTINGS CONNECTING THE ISLAND SINK | | IN THE KITCHEN AND THE TUB IN THE MASTER | | BATHROOM DO NOT GUIDE THE WASTE IN THE | | DIRECTION OF FLOW AS REQUIRED IN SECTION | | 706.3. | | 2. SEE RED LINE CORRECTIONS ON ONE SET | | OF PLANS AS AN EXAMPLE TO AID IN | | CORRECTING THE CODE VIOLATIONS. | | 3. GAS INDICATED ON PLANS. SEPARATE | | PLANS AND PERMIT REQUIRED FOR GAS. SEE | | ATTACHED SHEET FOR GAS PERMIT | | APPLICATION REQUIREMENTS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-27 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-27 |
Time |
09:06 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-16 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-16 |
Time |
15:24 |
Sent To |
|
|
Notes |
2007-03-16 15:25:50 | ***FAILED*** | | | | 1) SURVEY SHALL BE PROVIDED INDICATING THE LOCATION OF | | THE RESIDENCE AND THE LOCATION AND DIMENSION OF THE | | REVISED DRIVEWAY. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-27 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-27 |
Time |
17:52 |
Sent To |
I |
|
Notes |
2005-09-27 00:00:00 | PROVISO | | 1.REF. ON 2ND FLOOR GREAT ROOM MUST BE | | AN U/C REF. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | POOL/SPA/DECK. | | NOTE: SURVEY SHOWS A 6FT U.E. IN REAR OF | | PROPERTY, NOTHING CAN BE | | BUILT/CONSTRCUTED IN U.E. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-08-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-08-23 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-08-23 |
Time |
08:59 |
Sent To |
I |
|
Notes |
2005-08-23 00:00:00 | DENIED, | | 1. NEED TO PROVIDE THE DIMENSION OF | | DRIVEWAY & WALKWAY (LENGTH & WIDTH). | | **MUST MAINTAIN 1000SQ FT OR 75% OF | | LANDSCAPE WITHIN THE FIRST 25FT FRONT | | SETBACK***. | | 2. THE PROPOSED PORCH IS ENCROACHING 1FT | | INTO THE 25FT FRONT SETBACK. PLANS SHOWS | | 6FT INTO THE 30FT FRONT SETBACK. | | **MUST HAVE 25FT IN FRONT SETBACK***. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-05-20 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-20 |
Time |
11:15 |
Sent To |
I |
|
Notes |
2005-05-20 00:00:00 | DENIED, | | 1. NEED TO PROVIDE TWO COPY OF THE | | SURVEY WITH SITEPLANS | | 2. SITEPLAN NEED TO PROVIDE THE | | DIMENSION OF THE LOT SHOWING THE | | COMPLETE VIEW OF THE PROPERTY. | | 3. MUST PULL A SEPERATE PERMIT FOR | | POOL/DECK/SPA. CANNOT BUILD ANYTHING IN | | THE 12FT EASEMENT IN REAR OF PROPERTY. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|