Plan Review Stops For Permit 05050464 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-07-26 |
Time |
08:10 |
Rev Time |
1.50 |
Received By |
mjacobs |
Date |
2005-07-26 |
Time |
06:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-05-23 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-05-23 |
Time |
11:59 |
Sent To |
|
|
Notes |
2005-05-23 00:00:00 | BUILDING PLAN REVIEW | | PERMIT:05050464 | | ADD:2000 PALM BCH LKS BLVD | | CONT:S.O. ENTERPRISES,INC. | | TEL: (772)221-8354 | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW:1ST | | ACTION:DENIED | | | | 1) EACH SHEET SHALL BE CLEARLY | | SEALED,DATED,SIGNED AND HAVE THE PERSON | | RESPONSIBLE LICENSE NUMBER ON EACH | | SHEET.SEE F.A.CODE SEC.61G15-23.002 ALSO | | 471.025 | | | | 2) ON SHEET A-1, THE DOOR SCHEDULE | | MENTIONED B3 AND C2 BUT IN THE DATAIL | | AREA THEY ARE NOT SHOWN. PLEASE CLARIFY. | | | | 3) SHOW DETAILS OF HOW THE TOP AND | | BOTTOM TRACK PLATES WILL BE ATTATCHED TO | | STRUCTURE. | | | | 4) THE NEW WALLS ARE LABLED AS (1A) | | HOWEVER THERE IS NO DETAIL FOR A TYPE | | (1A) WALL. PLEASE MAKE CLEAR. | | | | BUILDING PLAN REVIEW | | MYRON JACOBS | | TEL: (561)805-6726 | | FAX: (561)659-8026 | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-18 |
Time |
07:08 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-08-18 |
Time |
07:08 |
Sent To |
|
|
Notes |
2005-08-18 00:00:00 | ELEC OK, PLANS STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-07-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-07-07 |
Time |
07:54 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-07-07 |
Time |
07:54 |
Sent To |
|
|
Notes |
2005-07-07 00:00:00 | ******** UNSAT ********* | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | AND SOME CHANGES IN PLANS HAVE COMMENTS. | | | | 1)NOTE: PLEASE SEE NOTE#1 FROM PREVIOUS | | REVIEWED REQUESTED THE ENGINEER | | RESPONSIBLE FOR DESIGN TO SIGN AND SEAL | | PLANS. THIS WAS DONE, HOWEVER ENGINEER'S | | TITLE BLOCK WAS REMOVED?? | | PLEASE SEE FAC 61G15-23.002 AND FS | | 471.023 FOR REQUIRED TITLEBLOCK AND | | INFORMAITON REQUIRED ON SAID TITLE | | BLOCK. | | | | 2)NOTE: PLEASE SEE RISER DIGRAM HAS NOW | | BEEN REVISED, PLEASE SEE PANEL "LB" IS | | STILL SHOWN AS MLO. PLEASE SEE RISER | | MENTIONS 175A BRKR. PLEASE SEE PANEL | | "LA" INDICATES BEING A 225A MCB? PLEASE | | CORRELATE. | | PLEASE SEE PANEL "LB" DOES NOT INDICATE | | ANY OCP FEEDING "LA"? IS THIS A FEED | | THRU LUGS PANEL? | | 408.16,240.21 ETC. | | | | 3)NOTE: PLEASE SEE PANEL 4H STILL | | INDICATES 200A OCP FEEDING 45KVA | | TRANSFORMER? ON #6 AWG. | | PLEASE SEE MAX OCP IN 450.3(125%). | | PLEASE ALSO SEE 240.4,310.16 FOR SIZING | | OF CONDUCTORS. | | | | 4)NOTE: PLEASE SEE 210.8B3 FOR | | KITCHEN/BRK RM RECEPTS WHICH REQUIRES | | ALL 15- AND 20-AMPERE, 125-VOLT | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | APPLIES TO EACH AND EVERY 15- AND | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | WHETHER OR NOT THE RECEPTACLE SERVES | | COUNTERTOP APPLIANCES. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETSFOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-05-20 |
Time |
07:42 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2005-05-20 |
Time |
07:34 |
Sent To |
|
|
Notes |
2005-05-20 00:00:00 | ********UNSAT *********** | | | | 1)NOTE: PLEASE SEE PLANS ARE CONTAINING | | A TITLE BLOCK OF SORTS WHICH REFERENCE A | | PE FOR PLANS, HOWEVER THE PE SHOWN HAS | | NOT SIGNEDAND SEALED PLANS.?? | | PLEASE SEE IF PE IS RESPONSIBLE FOR | | DESIGNAND ON PLANS , THEN THAT PE MUST | | SIGN,DATE AND SEALED PLANS. FS471.025 | | | | PLEASE SEE SEAL FOR ARCH (IF ARCH SEALS | | PLANS) IS CLEAR AND VISABLE WIH | | INFORMATION REQUIRED ON SEAL FOR P, M | | AND E SHEETS. | | FS 481.221 FAC 61G1-16.003 | | | | 2)NOTE: PLEASE CLARIFY MEANS OF DISC AND | | OCP FROM BUS RISER? | | PLEASE SEE 4H IS SHOWN AS MLO? THERE | | SHALL BE A MAIN AND OCP ON THE LINE SIDE | | 4H. | | PLEASE SEE PANELS ON THE SECONDARY SIDE | | OF THE TRANSFORMER ARE BOTH SHOWN AS | | MLO. | | PLEASE SEE THESE SHALL BOTH HAVE MCB'S | | INSTALLED. | | 215.5,408.16,240.21 ETC. | | | | 3)NOTE: PLEASE SEE 200A OCP SHOWN FOR | | MAIN SIDE OF 45 KVA TRANSFORMER DOES NOT | | MEET 450.3. A MAX OCP OF 125% IS ONLY | | PERMITTED. | | | | PLEASE BE SURE TO SEE ANY POSSIBLE | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | MAY AFFECT ELECTRICAL PLANS. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AN | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-07-29 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-07-29 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-05-26 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-05-26 |
Time |
09:16 |
Sent To |
|
|
Notes |
2005-05-26 00:00:00 | 1) PLEASE REFER TO COMMENTS FROM OTHER | | REVIEWERS IN REGARDS TO FS AND FAC | | REQUIREMENTS. | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM REMODELS. | | | | 3) ALL CONSTRUCTION, ALTERATION AND | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2951 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-06 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-06 |
Time |
10:26 |
Sent To |
P |
|
Notes |
2005-12-06 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-14 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-14 |
Time |
17:14 |
Sent To |
P |
|
Notes |
2005-11-14 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-20 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-20 |
Time |
11:47 |
Sent To |
P |
|
Notes |
2005-09-20 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-16 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-16 |
Time |
15:46 |
Sent To |
|
|
Notes |
2005-08-17 00:00:00 | TO "COMM" BD#1 | 2005-08-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-07-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-05 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-05 |
Time |
11:32 |
Sent To |
|
|
Notes |
2005-07-05 00:00:00 | TO "COMM" BD#31 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-06-23 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-05-10 |
Time |
11:06 |
Sent To |
|
|
Notes |
2005-05-20 00:00:00 | TO "COMM" BD#5 | 2005-05-13 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-07-25 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-25 |
Time |
15:06 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-07-25 |
Time |
15:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-06-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-06-23 |
Time |
11:58 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-06-23 |
Time |
11:48 |
Sent To |
|
|
Notes |
2005-06-23 00:00:00 | DENIED: | | SEAL OF THE ARCHITECT IS NOT LEGIBLE. | | THE ENIGNEER INDICATED ON THE MECHANICAL | | PLAN IS W. BRUCE MILLER, BUT HE DID NOT | | SIGN, SEAL OR DATE PLANS AS REQUIRED PER | | FS471.025 & FAC 61G15-23.003. | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | IF YOU HAVE QUESTIONS, PLEASE CONTACT | | PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-12-07 |
Time |
11:37 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2005-12-07 |
Time |
11:36 |
Sent To |
|
|
Notes |
2005-12-07 00:00:00 | REVISION OK - WATER AND SANT. RISER | | DIAGRAMS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2005-11-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-11-19 |
Time |
13:12 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-11-19 |
Time |
13:12 |
Sent To |
|
|
Notes |
2005-11-19 00:00:00 | DENIED; | | 1. BREAK SINK NOT SHOWN ON SANITARY | | RISER DIAGRAM. | | 2.WATER RISER PIPING IS NOT SIZED, SHOCK | | ARRESTORS FOR BREAK SINK ARE MISSING, | | WATER SEVICE IS PIPED WRONG AT HEATER | | AND SHUTOFF VALVE IS NOT SHOWN. | | 3.WATER RISER DIAGRAM SHOWS HOT AND COLD | | WATER TO BREAK SINK, AND ALSO HAS A NOTE | | AT THE SINK CALLING FORINSTA HOT | | PLEASE CORRECT. | | 4.OLD RISER DIAGRAM SHOWED NOTE SAID | | "TIE INTO EXISTINGBUILDING SANITARY AT | | RESTROOMS ABOVE 6TH FLOOR CEILING", | | REVISED PLAN READS,"ABOVE 5TH FLOOR | | CEILING. SUITE IS ON THE 7TH FLOOR. THE | | EXISTING 4" SANITARY PIPE AT BATHROOMS | | SHOULD NOT BE CAPPED OFF, THAT STACK | | BECOMES A VENT ON THE TOP FLOOR AND GOES | | OUT THE ROOF. | | ONE SET OF DRAWINGS MARKED IN RED. | | PLUMBING PLAN REVIED BY; | | JOHN LEECH | | 805-6695 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-03 |
Time |
09:59 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-10-03 |
Time |
09:59 |
Sent To |
|
|
Notes |
2005-10-03 00:00:00 | REVISION DENIED; | | ANY CHANGES TO THE PLANS MUST BE | | APPROVED BY DESIGN PROFESSIONAL WHO DREW | | THE PLANS. ALL CHANGES SUBMITED SHALL BE | | SUBMITED ON ARCHITECT LETER HEAD, | | CLOUDED, SEAL AND SIGNED. SEE CITY OF | | WEST PALM BEACH AMENDMENTS TO THE FBC | | CHAPTER 1, SEC. 104.2 AND 104.2.2. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-02 |
Time |
07:42 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-09-02 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-08-04 |
Time |
12:45 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-08-04 |
Time |
12:45 |
Sent To |
|
|
Notes |
2005-08-04 00:00:00 | DENIED; | | 1.WATER RISER DIAGRAM; SHOCK ARRESTORS | | REQUIRED AT BREAK SINK. PLEASE SIZE HOT | | AND COLD MAINS. | | 2.PAGE A-1 BREAK SINK SHALL BE OPEN | | FRONT PER FBC CHAPTER 11 SEC. 11.4.24.5. | | 3.SEE ELECTRICAL PLAN REVIEW NOTE # 1. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-06-18 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-06-18 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-06-18 |
Time |
11:59 |
Sent To |
M |
|
Notes |
2005-06-18 00:00:00 | PLUMBING PLAN REVIEW FBC 2001 | | PASS PENDING ELECTRICAL PLAN REVIEW, | | NOTE # 1 | | END OF COMMENTS | | QUESTIONS PAUL SCHMITZ 561-805-6692 |
|
|
Review Stop |
PC |
PERMIT CLERK |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|