Plan Review Details - Permit 05050382
Plan Review Stops For Permit 05050382
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-07-07 Cont ID  
Sent By lsmith Date 2005-07-07 Time 12:13 Rev Time 0.50
Received By lsmith Date 2005-07-07 Time 12:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-01 Cont ID  
Sent By lsmith Date 2005-06-01 Time 12:09 Rev Time 0.75
Received By lsmith Date 2005-06-01 Time 12:09 Sent To  
Notes
2005-06-01 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1. APPLICATION SAID "CONSTRUCT POOL &
 SPA ONLY"PLANS SHOW THERE IS A 405000
 BTU GAS HEATER & 4" CONCRETE DECK.
  
 2. SHOW ON PLANS THE SQ. FOOTAGE OF THE
 DECK.
  
 3. 104.6.5 BUILDING PERMIT VALUATION. IF
 IN THE OPINION OF THE BUILDING OFFICIAL
 THE CLAIMED VALUATION OF BUILDING, AL-
 TERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED ESTIMATES
 AND/OR BONA FIDED SIGNED CONTRACTS (EX-
 CLUDING LAND VALUE) TO MEET THE APPROVAL
 OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION FOR BUILDINGS AND
 SYSTEMS SHALL BE FOUND IN MARSHALL AND
 SWIFT OR THE SOUTHERN BUILDING CODE
 CONGRESS INTERNATIONAL VALUATION TABLES,
 LATEST EDITION, AND SHALL BE BASED ON
 TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHAN-
 ICAL, INTERIOR FINISH, NORMAL SITE WORK
 (EXCAVATION AND BACKFILL FOR BUILDINGS),
 ARCHITECTURAL AND DESIGN FEES, OVERHEAD
 AND PROFIT, EXCLUDING ONLY LAND VALUE.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-05-09 Cont ID  
Sent By ptjomsto Date 2005-05-09 Time 15:15 Rev Time 0.00
Received By ptjomsto Date 2005-05-09 Time 15:15 Sent To  
Notes
2005-05-09 00:00:00HISTORIC APPROVED 5/9/05 BY N F

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-06-23 Cont ID  
Sent By btrobaug Date 2005-06-23 Time 11:06 Rev Time 0.33
Received By btrobaug Date 2005-06-23 Time 10:38 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-05-20 Cont ID  
Sent By btrobaug Date 2005-05-20 Time 17:52 Rev Time 0.33
Received By btrobaug Date 2005-05-20 Time 17:39 Sent To P
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-06-01 Cont ID  
Sent By lsmith Date 2005-06-01 Time 12:08 Rev Time 0.00
Received By lsmith Date 2005-06-01 Time 12:08 Sent To  
Notes
2005-06-01 00:00:00HISTORIC APPROVAL NOTES TYPED INTO
 BUILDING REVIEW BOX IN ERROR BY PT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-08 Cont ID  
Sent By shill Date 2005-06-08 Time 10:09 Rev Time 0.00
Received By shill Date 2005-06-08 Time 10:09 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-20 Cont ID  
Sent By adarroug Date 2005-05-20 Time 13:28 Rev Time 0.00
Received By adarroug Date 2005-05-20 Time 13:28 Sent To E
Notes
2005-05-20 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-05-10 Cont ID  
Sent By adarroug Date 2005-05-10 Time 12:02 Rev Time 0.00
Received By adarroug Date 2005-05-10 Time 12:02 Sent To Z
Notes
2005-05-10 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-22 Cont ID  
Sent By jleech Date 2005-06-22 Time 18:01 Rev Time 0.50
Received By jleech Date 2005-06-22 Time 18:01 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-05-27 Cont ID  
Sent By kstevens Date 2005-05-27 Time 16:30 Rev Time 0.55
Received By kstevens Date 2005-05-27 Time 16:30 Sent To B
Notes
2005-05-27 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1. FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON THE
 WATER SERVICE. (ADD TO NOTES)
 2. FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 3. FBC-2001 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG. SEC 605.21 PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES).
 4. MANUF. SPECIFICATION SHEETS DO NOT
 SHOW POSITIVE MEANS TO RETAIN WATER
 SHOULD THE PUMP SHUT OFF. AN EXTERIOR
 HARTFORD LOOP IS REQUIRED. SECTION
 424.2.14.2
 5. FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2005-05-19 Cont ID  
Sent By mmclean Date 2005-05-19 Time 11:39 Rev Time 0.00
Received By mmclean Date 2005-05-19 Time 11:39 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved