Plan Review Stops For Permit 05042090 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-28 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-28 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2005-04-28 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)THE APPROVED ASSEMBLY SUBMITTED HAS | | A DP LIMITATION OF -45 WITH GENERAL | | LIMITATION #9 WHICH DOES NOT ALLOW | | ENHANCED FASTENING FOR CORNER AND EDGE | | ZONES.CITY OF WPB IS IN THE 140 MPH | | WIND ZONE, SEE FBC TABLE 1606.2B. |
|
|
|