Plan Review Stops For Permit 05041195 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-06-24 |
Time |
15:49 |
Rev Time |
0.66 |
Received By |
alange |
Date |
2005-06-24 |
Time |
15:49 |
Sent To |
|
|
Notes |
2005-06-24 00:00:00 | REVISED PAGES OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-05-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-05-17 |
Time |
10:52 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2005-05-17 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-06-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-18 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-18 |
Time |
12:44 |
Sent To |
PC |
|
Notes |
2006-06-18 00:00:00 | REVISION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-29 |
Time |
19:23 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-06-29 |
Time |
19:13 |
Sent To |
|
|
Notes |
2005-06-29 00:00:00 | **** REDLINED **** | | | | PLEASE SEE ELECTRICAL PANEL SHOWN WITH | | ZERO CLEARENCE. SEE 110.26 IF ALTERATION | | WAS MADE AFTER FINAL ELECTRICAL | | INSPECTION FOR BLDG, ALL CLEARENCES | | SHALL BE BROUGHT UP TO CODE. | | | | PLEASE SEE ALL OLD/VOIDED SHEETS WERE | | REMOVED FROM SETS. THIS WAS REQUESTED ON | | PREVIOUS REVIEW, HOWEVER THIS WAS NOT | | DONE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
14:43 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-04-26 |
Time |
14:43 |
Sent To |
|
|
Notes |
2005-04-26 00:00:00 | ************ UNSAT ********** | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH A PANEL | | SCHEDULE(S) TO BE SUBMITTED. | | 215.5 | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 3)NOTE: PLEASE ALSO REVISE LOAD | | CALCULATIONS FOR EXISTING PANELS. | | 220,215.5 | | | | 4)NOTE: PLEASE INCLUDE ALL SWITCH LEGS | | ON PLANS. | | 215.5 | | | | 5)NOTE: PLEASE SEE SOME AREAS ON PLANS | | DO NOT APPEAR TO SHOW ANY DOORWAYS, | | DOORS OR OPENINGS. | | | | PLEASE SEE SOME OF THE ABOVE NOTES/ | | AREAS ARE REDLINED ON PLANS. | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | COMPLETE SETS FOR REVIEW AND STMAPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-07-01 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-07-01 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-05-05 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-05-05 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-05-05 |
Time |
10:41 |
Sent To |
|
|
Notes |
2005-05-05 00:00:00 | 1) ALL CONSTRUCTION, ALTERATION AND | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | ARE REQUIRED FOR FIRE ALARM AND FIRE | | SPRINKLER REMODELS. | | | | 3) DRAWINGS DON'T SHOW ANY SMOKE | | DETECTOR LOCATIONS. HARD WIRED SMOKE | | ALARMS ARE REQUIRED IN ACCORDANCE WITH | | NFPA 101. | | | | 4) PLEASE SEE COMMENTS BY OTHER | | REVIEWERS. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-14 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-14 |
Time |
14:48 |
Sent To |
P |
|
Notes |
2006-06-14 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-14 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-14 |
Time |
11:50 |
Sent To |
E |
|
Notes |
2006-06-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-09 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-09 |
Time |
11:46 |
Sent To |
P |
|
Notes |
2005-08-09 00:00:00 | TO "P" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-21 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-21 |
Time |
15:40 |
Sent To |
P |
|
Notes |
2005-07-21 00:00:00 | TO "KSTEVENS" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-14 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-14 |
Time |
17:19 |
Sent To |
|
|
Notes |
2005-06-20 00:00:00 | COMM BOARD #51 | | | 2005-06-14 00:00:00 | WAITING FOR COMM BOARD | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-05-26 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2005-04-25 |
Time |
08:28 |
Sent To |
|
|
Notes |
2005-04-25 00:00:00 | TO "COMM" BD#25 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-07-19 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-07-19 |
Time |
13:37 |
Sent To |
|
|
Notes |
2005-07-19 00:00:00 | PLANS REVIEWED AND PASSED BYPATTY | | KUAUSS 7/11/05 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-05-23 |
Time |
09:08 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2005-05-23 |
Time |
09:08 |
Sent To |
|
|
Notes |
2005-05-23 00:00:00 | MECHANICAL PLANS WERE NOT SUBMITTED WITH | | BUILDING PLANS.MECHANICAL CONTRACTOR | | IS SIGNED FOR WORK TO BE PERFORMED. | | MECHANICAL PLANS ARE TO BE SUBMITTED AND | | APPROVED PRIOR TO MECHANICAL INSPECTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-22 |
Time |
14:14 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-06-22 |
Time |
14:14 |
Sent To |
PC |
|
Notes |
2006-06-22 00:00:00 | REVISION: ADDING 2 (TWO) NEW EXTERIOR | | HOSE BIBBS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-08-03 |
Time |
15:33 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2005-08-03 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-08-03 |
Time |
07:26 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2005-08-03 |
Time |
07:26 |
Sent To |
|
|
Notes |
2005-08-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | A. FROM PREVIOUS REVIEW: | | 1. SHT P-1 ALL FIXTURES THAT HAVE BEEN | | REMOVED, MOVED, OR ADDED SHALL BE SHOWN | | ON THE RISER DIAGRAM THAT REFLECTS THE | | CHANGE. THE SINK IN THE HALLWAY NEXT TO | | THE DINING ROOM IS NOT SHOWN ON THE | | RISER DIAGRAM. - SHT A-2 INDICATES THAT | | THIS SINK HAS BEEN RELOCATED FROM THE | | MASTER BEDROOM AND SHT A-1 DOES NOT SHOW | | A SINK AS EXISTING. SHT P-1 INDICATES | | THAT THIS IS AN EXISTING SINK. PLEASE | | CORRELATE ARCHITECTURAL SHEETS AND | | PLUMBING SHEET. SECTIONS 104.2.1 AND | | 104.3.1.1. | | 2. ALL MEP SHEETS - ENGINEERS SHALL | | INDICATE THEIR CERTIFICATE OF | | AUTHORIZATION ON EACH SHEET. FAC | | 61G15-23.002(2) & FS 471.025. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-07-12 |
Time |
14:32 |
Rev Time |
0.65 |
Received By |
kstevens |
Date |
2005-07-12 |
Time |
14:32 |
Sent To |
|
|
Notes |
2005-07-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. SHT P-1 ALL FIXTURES THAT HAVE BEEN | | REMOVED, MOVED, OR ADDED SHALL BE SHOWN | | ON THE RISER DIAGRAM THAT REFLECTS THE | | CHANGE. - THE SINKIN THE HALLWAY NEXT | | TO THE DINING ROOM IS NOT SHOWN ON THE | | RISER DIAGRAM. THE SINK THAT WAS DELETED | | NEAR THE MASTER BATH IS NOT SHOWN ON THE | | SANT. RISER DIAGRAM AS BEING DELETED AND | | CAPPED OFF. - THE LAV IN THE POWDER ROOM | | NEXT TO THE MEDIA ROOM HAS BEEN MOVED | | AND THE SHOWER IN THE SAME BATHROOM HAS | | BEEN DELETED, BUT HAS NOT BEEN REFLECTED | | ON THE SANT. RISER DIAGRAMS. SECTIONS | | 104.2.1. & 104.3.1.1. | | 2. ALL MEP SHEETS - ENGINEERS SHALL | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | AND LICENSE NUMBER ON EACH SHEET. IF | | PRACTICING THROUGH A DULY AUTHORIZED | | ENGINEERING BUSINESS, ENGINEERS SHALL | | LEGIBLY INDICATE THEIRNAME AND LICENSE | | NUMBER, AS WELL AS, THE NAME, ADDRESS, | | AND CERTIFICATE OF AUTHROIZATION NUMBER | | OF THE ENGINEERING BUSINESS ON EACH | | SHEET. FAC 61G15-23.002(2) & FS 471.025. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-05-26 |
Time |
15:49 |
Rev Time |
1.33 |
Received By |
kstevens |
Date |
2005-05-26 |
Time |
15:49 |
Sent To |
|
|
Notes |
2005-05-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1. SANITARY RISERS ARE ENGINEERED SYSTEM | | (SOVENT) AND ALL CHANGES TO THE | | ENGINEERED SYSTEM SHALL BE DONE BY AN | | ENGINEER. SUBMIT CHANGES TO THE SOVENT | | SYSTEM, SIGNED, SEALED, & DATED BY AN | | ENGINEER IN ISOMETRIC FORM SHOWING ALL | | CONNECTIONS TO THE STACKS AND INDICATE | | STACK NUMBER MOVED FIXTURES OR ADDED | | FIXTURES ARE CONNECTED TO. SECTION | | 104.3.1.1. | | 2. SHTS A-1 & A-2 STATE "DROP EXISTING | | FIREPLACE" PLEASE CLARIFY. DOES THIS | | MEAN THE FIREPLACE WILL BE DELETED? | | SECTION 104.2.1. | | 3. SHT A-1 IN THE INSTALLATION OR | | REMOVAL OF ANY PART OF A DRAINAGE | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | SECTION 704.5 - THE DEMO'D/REMOVED | | DRAINAGE PIPE WILL BE FIELD INSPECTED | | PRIOR TO COVERING. SECTION 105.6. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|